*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s 2-way high response valves series TDP are particularly suitable for demanding controlled and closed loop applications where high flow has to be precisely controlled at highest dynamics.
The proportional throttle valves have a 2-stage design consisting of a DFplus pilot valve and a main stage with poppet and LVDT. With the DFplus pilot valve the TDP achieves extremely fast response times: from 10.5 ms (NG25) up to 28 ms (NG100) with an accuracy of <0.1 % of the nominal flow. The pilot valve actively controls the poppet – independent of the pressure conditions in the main ports. The integrated electronics in the pilot of the TDP has two control loops for the main poppet and the pilot spool.
Markets:
• Industrial
•; Molding
Features/Benefits:
• High precision – for high quality products, minimum scrap rate and long machine lifetime
• Extremely fast step response – shortens material processing and thus cycle times
• Short delivery time – no warehousing necessary
• Active pilot operated 2-way high-response valve
• Cavity and mounting pattern according to ISO 7368
•; Flow direction B to A and A to B
•; Completely mounted and adapted unit with integrated electronics
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Fail save position in case of electrical and/or hydraulic power down
• In order to ensure the closed position, pilot pressure is required.
• 8 sizes NG25 up to NG100
Applications:
• Die cast
• General presses
• Injection molding
Please note:
It is basically required that the pilot pressure is at the level of the system pressure. At low system pressure the pilot pressure should be min. 140 bar, when high valve dynamics are desired.
Action | SKU | Availability | Price | Mounting Position | Minimum Operating Temperature | Operation Type | Division | Maximum Flow Rate | Flow Rate | Actuation Type | Pilot Inlet / Drain Locations | Performance | Product Series | Configuration | Maximum Operating Temperature | Seal Material | Maximum Operating Pressure | Weight | For Fluid Type | Body Material | Mounting Type | Function | Electronics Type | Port Connection | Signal Input | Marking | Seal Material | Spool Design | Performance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TDP025EH79C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 380 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 11 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG25 | 0 - +10 V | Standard | NBR | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP025EH99C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 420 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 11 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG25 | 0 - +10 V | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP025EH99C2VB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 420 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | FPM | 350 bar | 11 kg | Water Glycol | Steel | Slip-in Cartridge | 2-Way | Onboard | NG25 | 0 - +10 V | Standard | FPM | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP032EH79C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 750 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 13 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | 0 - +10 V | Standard | NBR | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP032EH99C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 850 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 13 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | 0 - +10 V | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP032EH99C2NE0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 850 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 13 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | 0- +20 mA | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP032EH99C2NS0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 850 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 13 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | +4- +20 mA | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP032EH99C2VB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 850 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | FPM | 350 bar | 13 kg | Water Glycol | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | 0 - +10 V | Standard | FPM | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP032EH99C2VS0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 850 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | FPM | 350 bar | 13 kg | Water Glycol | Steel | Slip-in Cartridge | 2-Way | Onboard | NG32 | +4- +20 mA | Standard | FPM | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP040EH79C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1300 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 15 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | 0 - +10 V | Standard | NBR | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP040EH79C2NS0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1300 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 15 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | +4- +20 mA | Standard | NBR | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP040EH79C2VB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1300 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | FPM | 350 bar | 15 kg | Water Glycol | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | 0 - +10 V | Standard | FPM | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP040EH99C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1500 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 15 kg | Hydraulic Oil According to DIN 51524 | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | 0 - +10 V | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP040EH99C2NE0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1500 L/min | n/a | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 15 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | 0- +20 mA | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | ||
TDP040EH99C2NS0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1500 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 15 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | +4- +20 mA | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP040EH99C2VB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1500 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | FPM | 350 bar | 15 kg | Water Glycol | Steel | Slip-in Cartridge | 2-Way | Onboard | NG40 | 0 - +10 V | Standard | FPM | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP050EH79C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1700 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 26 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG50 | 0 - +10 V | Standard | NBR | Progressive | Closed loop, VCD® performance, integrated electronics | |
TDP050EH79C2VB0XG537 | Backordered | POR | Unrestricted | Pilot | Industrial Systems Division Europe | VCD-actuator | High Response for Controlled Applications | High-response Valve | Steel | Slip-in Cartridge | 2-Way | Onboard | Proprietary Item | ||||||||||||||||
TDP050EH99C2NB0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1900 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 26 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG50 | 0 - +10 V | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics | |
TDP050EH99C2NE0 | Backordered | POR | Unrestricted | -20 °C | Pilot | Industrial Systems Division Europe | 1900 L/min | n/a | VCD-actuator | External/external | High Response for Controlled Applications | High-response Valve | n/a | 50 °C | NBR (suitable for HFC fluids) | 350 bar | 26 kg | HFC Fluids | Steel | Slip-in Cartridge | 2-Way | Onboard | NG50 | 0- +20 mA | Standard | NBR | Linear | Closed loop, VCD® performance, integrated electronics |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.