• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cavity Size
  • Configuration
  • Configuration
  • Division
  • Division
  • Drain Option
  • Filter Efficiency Rating
  • Flow Direction
More Filters...

2 Way Pilot Operated Directional Control Valves

Picture for category 2 Way Pilot Operated Directional Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s series of 2-way, pilot-operated directional control valves feature a robust design for maximum durability that can operate with hydraulic system flows as high as 100 lpm and pressures up to 420 bar. The high pressure and flow capabilities of Parker’s selection make these valves suitable for high flow switching or unloading applications within a broad range of markets, such as the aerial, construction, material handling and industrial markets.

Normally-open or normally-closed options are available depending on application needs, and can even be configured with an additional port in order to externally vent the spring chamber. Parker’s external spring chamber venting design is especially advantageous when high pilot pressures are not readily available, which will help ensure proper valve and system operation.

Markets:
• Aerial
• Construction equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Off-highway equipment

Features/Benefits:
• High flow and pressure capacity
• Two switching and one compensating spring available
• Very accurate flow regulation when used with separate orifice
• Sealed pilot option available
• Industry common cavity
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Unloader valve
• Switching valve

Additional Technical Insight:
Parker’s 2-way, pilot-operated series of directional control valves are available both normally-open and normally-closed, with flow and pressure ranging up to 100 lpm (26 gpm) and 420 bar (6,000 psi) respectively. These valves open or close the main flow path by utilizing pilot pressure from elsewhere within the hydraulic system and acting against the internal spring which keeps the valve in its "normal" position. A selection of valves in this series use 3 ports, with pilot pressure entering port 1 (nose) of the valve, and main flow passing through ports 2 and 3 on the sides of the valve. When a pilot signal is supplied to port one, pressure acts upon the spool and compresses the spring, opening/closing the flow path from port 2 to port 3 (depending if the valve is normally-closed or normally-open). Simply, the pilot pressure will shift the valve from its normal position. Because the spring chamber is vented internally through port 3, it is advised that port 3 is located on the lower pressure side of the valve and/or the tank line.  When the pilot signal is removed, the spring acts upon the spool forcing the valve back into its normal position. Pilot pressures of 5 and 10 bar are available as standard options on this valve. This valve series also includes a selection of 2-way, 2 position, 4 ported valves. Similar to the 3 ported options, these valves receive the pilot signal at port 1, shifting the valve against the spring and opening/closing flow from port 2 to port 3, however the additional 4th port is connected to the spring chamber, thus allowing the oil to vent independently of the pressure seen at port 3. This additional 4th port feature adds flexibility for the hydraulic oil to flow either from port 2 to 3 or from port 3 to 2 with less effect on the pilot pressure and spring force interaction.

On the 3 ported valves, the 3rd port should be connected to the lower pressure flow path and/or ideally the tank line.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceMinimum Operating TemperatureStandard Flow Rate SettingFilter Efficiency RatingDrain OptionActuation TypePilot LocationSwitching PressureOperating TemperatureFor Fluid TypeMaximum Operating PressureMaximum Operating TemperatureInstallation TorqueOperation TypeFunctionMaximum Flow RateMaximum Inlet Pressure RatingWeightLeak RateValve MaterialDivisionMaximum Kinematic ViscosityCavity SizeFlow RateSealed Pilot IncludedBody MaterialDivisionSeal MaterialFlow DirectionConfigurationSealed Pilot IncludedSeal MaterialConfigurationFlow RateSwitching Pressure
R04A4-10.0N
Backordered
POR
-34 °C12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal145 psi-34 to +121 °CMineral-based or synthetic hydraulic fluids6000 psi+121 °C50 NmPilot OperatedDiverter80 L/min420 bar0.17 kg55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenNoNitrileNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04A4-10.0NS
Backordered
POR
-30 °F12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal145 psi-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+121 °C50 NmPilot OperatedDiverter21 Gal/min420 bar0.17 kg55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-480 L/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenYesNitrileNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04A4-10.0V
Backordered
POR
-15 °F12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal145 psi-26 to +204 °CMineral-based or synthetic hydraulic fluids420 bar+204 °C50 NmPilot OperatedDiverter80 L/min6000 psi0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minNoN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally OpenNoFluorocarbonNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04A4-5.0N
Backordered
POR
-30 °F12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal73 psi-30 to +250 °FMineral-based or synthetic hydraulic fluids420 bar+121 °C37 lb-ftPilot OperatedDiverter21 Gal/min420 bar0.17 kg55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenNoNitrileNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04A4-5.0NS
Backordered
POR
-34 °C12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal5 bar-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+121 °C50 NmPilot OperatedDiverter21 Gal/min6000 psi0.17 kg55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenYesNitrileNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04A4-5.0V
Backordered
POR
-15 °F47 L/minISO 4406 18/16/13, SAE Class 4ExternalPilot to CloseExternal5 bar-15 to +400 °FMineral-based or synthetic hydraulic fluids420 bar+204 °C37 lb-ftPilot OperatedDiverter21 Gal/min420 bar0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-480 L/minNoN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally OpenNoFluorocarbonNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04B4-10.0N
Backordered
POR
-34 °C12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to OpenExternal145 psi-34 to +121 °CMineral-based or synthetic hydraulic fluids6000 psi+121 °C50 NmPilot OperatedDiverter80 L/min420 bar0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally ClosedNoNitrileNormally Closed21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04B4-10.0NS
Backordered
POR
-34 °C47 L/minISO 4406 18/16/13, SAE Class 4ExternalPilot to OpenExternal10 bar-30 to +250 °FMineral-based or synthetic hydraulic fluids420 bar+250 °F37 lb-ftPilot OperatedDiverter21 Gal/min6000 psi0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally ClosedYesNitrileNormally Closed21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04B4-5.0N
Backordered
POR
-30 °F47 L/minISO 4406 18/16/13, SAE Class 4ExternalPilot to OpenExternal5 bar-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+121 °C50 NmPilot OperatedDiverter21 Gal/min6000 psi0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-480 L/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally ClosedNoNitrileNormally Closed21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04B4-5.0NS
Backordered
POR
-30 °F12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to OpenExternal73 psi-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+250 °F50 NmPilot OperatedDiverter80 L/min6000 psi0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally ClosedYesNitrileNormally Closed21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04B4-5.0V
Backordered
POR
-15 °F12 Gal/minISO 4406 18/16/13, SAE Class 4ExternalPilot to OpenExternal73 psi-26 to +204 °CMineral-based or synthetic hydraulic fluids6000 psi+204 °C50 NmPilot OperatedDiverter80 L/min6000 psi0.37 lb55 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-421 Gal/minNoN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally ClosedNoFluorocarbonNormally Closed21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04C3-10.0N
1 in stock
POR
-30 °F10 Gal/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal10 bar-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+250 °F37 lb-ftPilot OperatedDiverter21 Gal/min6000 psi0.33 lb50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-321 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenNoNitrileNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04C3-10.0V
Backordered
POR
-26 °C10 Gal/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal145 psi-26 to +204 °CMineral-based or synthetic hydraulic fluids6000 psi+400 °F50 NmPilot OperatedDiverter80 L/min6000 psi0.15 kg50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-380 L/minNoN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally OpenNoFluorocarbonNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04C3-10.0VS
Backordered
POR
-15 °F10 Gal/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal145 psi-15 to +400 °FMineral-based or synthetic hydraulic fluids6000 psi+204 °C37 lb-ftPilot OperatedDiverter80 L/min420 bar0.15 kg50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-380 L/minYesN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally OpenYesFluorocarbonNormally Open21 GAL/MIN, 80 L/MIN145 PSI, 10 BAR
R04C3-5.0N
1 in stock
POR
-34 °C40 L/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal73 psi-30 to +250 °FMineral-based or synthetic hydraulic fluids6000 psi+250 °F50 NmPilot OperatedDiverter80 L/min6000 psi0.15 kg50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-321 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenNoNitrileNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04C3-5.0NS
Backordered
POR
-34 °C40 L/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal5 bar-30 to +250 °FMineral-based or synthetic hydraulic fluids6000 psi+250 °F37 lb-ftPilot OperatedDiverter21 Gal/min420 bar0.33 lb50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-321 Gal/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenYesNitrileNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04C3-5.0V
Backordered
POR
-15 °F10 Gal/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal73 psi-26 to +204 °CMineral-based or synthetic hydraulic fluids420 bar+400 °F37 lb-ftPilot OperatedDiverter21 Gal/min6000 psi0.15 kg50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-380 L/minNoN/AMobile Hydraulic Systems Division EuropeFluorocarbon2-3 or 3-2Normally OpenNoFluorocarbonNormally Open21 GAL/MIN, 80 L/MIN73 PSI, 5 BAR
R04C3-7.7N
2 in stock
POR
-34 °C40 L/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal7.7 bar-34 to +121 °CMineral-based or synthetic hydraulic fluids6000 psi+250 °F50 NmPilot OperatedDiverter80 L/min6000 psi0.15 kg50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-321 Gal/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenNoNitrileNormally Open21 GAL/MIN, 80 L/MIN112 PSI, 7.7 BAR
R04C3-7.7NS
Backordered
POR
-30 °F10 Gal/minISO 4406 18/16/13, SAE Class 4InternalPilot to CloseExternal112 psi-34 to +121 °CMineral-based or synthetic hydraulic fluids420 bar+121 °C50 NmPilot OperatedDiverter80 L/min6000 psi0.33 lb50 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-321 Gal/minYesN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally OpenYesNitrileNormally Open21 GAL/MIN, 80 L/MIN112 PSI, 7.7 BAR
R04D3-10.0N
Backordered
POR
-34 °C60 L/minISO 4406 18/16/13, SAE Class 4InternalPilot to OpenExternal145 psi-30 to +250 °FMineral-based or synthetic hydraulic fluids6000 psi+121 °C50 NmPilot OperatedDiverter100 L/min6000 psi0.15 kg100 @ 1450 PSI (100 BAR) cm3/minAll parts steel. All operating parts hardened steelHydraulic Cartridge Systems Division45-2000 SSU (6 to 420 cSt)C10-3100 L/minNoN/AMobile Hydraulic Systems Division EuropeNitrile2-3 or 3-2Normally ClosedNoNitrileNormally Closed26 GAL/MIN, 100 L/MIN145 PSI, 10 BAR

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains