• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Configuration
  • Division
  • Filter Efficiency Rating
  • Flow Rate
  • For Fluid Type
  • Function
  • Ingress Protection Rating
  • Input Voltage
More Filters...

2-Way Slip-In Cartridge Valve - Series TDW

Picture for category 2-Way Slip-In Cartridge Valve - Series TDW

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's active pilot operated 2/2 way throttle valves TDW enables to open and close the main poppet solely by pilot pressure, independent of pressure build-up in the main ports A and B. Thus they provide safe switching resulting in reliable operation.

The main poppet is designed hollow and mostly pressure balanced. The operation is accomplished via minimal control surfaces resulting in low pilot oil demand and fast switching operations.

Markets:
• Industrial
• Molding
• Oil & Gas

Features/Benefits:
• Active pilot operated 2/2 way cartridge valve - ensures safe switching
• Various sizes, NG25 - NG125 - allows extremely variable use
• Cavity and mounting pattern according to ISO 7368 (except for size NG125) - for quick and easy integration
• Lower recess in the standardized mounting cavity is no longer required - minimizes pressure losses
• Flow-optimized sleeve - improved energy efficiency
• Fast switching operations - optimized process speed
• Supplied as one unit - facilitates mounting and dismounting
• Short delivery time for most sizes - no warehousing necessary
• Position monitoring and stroke limiter optional

Applications:
• Suitable for general hydraulic applications
• General presses
• Injection molding
• Die cast
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionFlow RateConfigurationInput VoltageActuation TypeDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureBody MaterialMounting TypeSeal MaterialOperation TypeFor Fluid TypeMounting PositionMinimum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureWeightMinimum Kinematic ViscosityFilter Efficiency RatingMaximum Fluid TemperatureIngress Protection RatingProduct SeriesMaximum Flow RatePilot Inlet / Drain LocationsMarkingMaterial - SealsPort ConnectionOrifice 1 SizeOrifice 2 SizeOrifice 3 SizeSolenoid OptionPilot StagePoppet DesignPosition Control Type
TDW050EW19C2N09JW0121414
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.2 mm1.4 mm1.4 mmStandardWith DC valve, normally closedStandard sinus poppetW/o position control
TDW050EW19C2N09JW0189999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenStandardWith DC valve, normally closedStandard sinus poppetW/o position control
TDW050EW19C2N29JW0189999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenStandardWith DC valve, normally closedStandard sinus poppetStroke limiter
TDW050EW89C2N09JW0189999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenStandardWith DC valve, normally closedSinus poppet with overlapW/o position control
TDW050EW89C2N81JW0189999
Backordered
POR
2-Wayn/an/a24SolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenStandardWith DC valve, normally openSinus poppet with overlapStart position monitored
TDW050EW89C2N89JW0189999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenStandardWith DC valve, normally closedSinus poppet with overlapStart position monitored
TDW050EW89C2N89JWT189999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve1900 L/minExternal/externalStandardNBRNG501.8 mmOpenOpenWithout manual overrideWith DC valve, normally closedSinus poppet with overlapStart position monitored
TDW063EW19C2N02990808
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C23 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG63Open0.8 mm0.8 mmN/AWith cover plate, X = closing, Y = openingStandard sinus poppetW/o position control
TDW063EW19C2N02992020
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG63Open2 mm2 mmN/AWith cover plate, X = closing, Y = openingStandard sinus poppetW/o position control
TDW063EW19C2N09JW0209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632 mmOpenOpenStandardWith DC valve, normally closedStandard sinus poppetW/o position control
TDW063EW19C2N22992020
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG63Open2 mm2 mmN/AWith cover plate, X = closing, Y = openingStandard sinus poppetStroke limiter
TDW063EW89C2N02992020
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG63Open2 mm2 mmN/AWith cover plate, X = closing, Y = openingSinus poppet with overlapW/o position control
TDW063EW89C2N09JW0209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632 mmOpenOpenStandardWith DC valve, normally closedSinus poppet with overlapW/o position control
TDW063EW89C2N81JW0209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632 mmOpenOpenStandardWith DC valve, normally openSinus poppet with overlapStart position monitored
TDW063EW89C2N81JWT209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632.0 mmOpenOpenWithout manual overrideWith DC valve, normally openSinus poppet with overlapStart position monitored
TDW063EW89C2N82189999
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG631.8 mmOpenOpenN/AWith cover plate, X = closing, Y = openingSinus poppet with overlapStart position monitored
TDW063EW89C2N82992020
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG63Open2 mm2 mmN/AWith cover plate, X = closing, Y = openingSinus poppet with overlapStart position monitored
TDW063EW89C2N89JW0209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632 mmOpenOpenStandardWith DC valve, normally closedSinus poppet with overlapStart position monitored
TDW063EW89C2N89JWT209999
Backordered
POR
2-Wayn/an/a24 VDCSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C49 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve3600 L/minExternal/externalStandardNBRNG632 mmOpenOpenWithout manual overrideWith DC valve, normally closedSinus poppet with overlapStart position monitored
TDW080EW19C2N02992525
Backordered
POR
2-Wayn/an/an/aSolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSteelSlip-in CartridgeNBRPilotHydraulic Oil According to DIN 51524Unrestricted-25 °C60 °C400 cSt-20 °C102 kg20 cStISO 4406; 18/16/1360 °CIP65 in accordance with EN 60529Throttle valve4500 L/minExternal/externalStandardNBRNG80Open2.5 mm2.5 mmN/AWith cover plate, X = closing, Y = openingStandard sinus poppetW/o position control

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains