• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Configuration
  • Division
  • Electronics Type
  • Flow Rate
  • For Fluid Type
  • Function
  • Marking
  • Maximum Ambient Temperature
More Filters...

3-Way High-Response Valve - Series TPQ

Picture for category 3-Way High-Response Valve - Series TPQ

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The active pilot operated, 3-way high-response valves in cartridge design series TPQ are used in applications where high flow has to be precisely controlled at maximum dynamics. In this way they provide enhanced process accuracy and higher machine output. Typical applications are die cast, injection molding and hydraulic presses.

Markets:
• Industrial
• Molding

Features/Benefits:
• Mounting pattern according to ISO 7368, cavity according to Parker house norm
• 6 sizes NG25 up to NG80 - fits almost all hydraulic systems
• Applicable for directional, speed, position, force and pressure controls - allows extremely variable use
• Very robust valve design - enables less downtime
• Closed-loop control of flows - enhanced process accuracy through high-precision production
• Fast step response - higher machine output thanks to shorter cycle times
• Short delivery time - no warehousing necessary
• Flow direction A to T and P to A
• Completely mounted adapted unit with integrated electronics
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Fail safe position in case of electrical and/or hydraulic power down

Applications:
• Suitable for general hydraulic applications
• Die cast
• Injection molding
• General presses

Function
TPQ has a 2-stage design consisting of a DFplus pilot valve and a main stage with spool and LVDT.

With the DFplus pilot valve the TPQ achieves extremely fast response times: from 7 ms (NG25) up to 20 ms (NG80) with an accuracy of <0.1 % of the nominal flow. The pilot valve actively controls the spool – independent of the pressure conditions in the main ports.

It is basically required that the pilot pressure is at the level of the system pressure. At low system pressure the pilot pressure should be min. 140 bar, when high valve dynamics are desired.

The integrated electronics in the pilot of the TPQ has two control loops for the main cone and the pilot spool.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPricePerformanceMaximum Operating TemperatureProduct SeriesSpool TypeMaximum Operating PressureWeightSeal MaterialConfigurationMounting TypeBody MaterialElectronics TypeMaximum Ambient TemperatureMinimum Ambient TemperatureMounting PositionFor Fluid TypeFunctionOperation TypeDivisionMinimum Operating TemperatureSpool DesignPilot Inlet / Drain LocationsFlow RateActuation TypeMaximum Flow RateSignal InputSpool CodePort ConnectionMarkingSeal Material
TPQ025WH25P2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar11 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator200 L/min4-+20 mAP: positive input signal A-TNG25StandardNBR
TPQ025WH25P2VB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar11 kgFPMn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedOthers3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator200 L/min0-&#177;10 VP: positive input signal A-TNG25StandardFPM
TPQ025WH25T2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar11 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator200 L/min0-&#177;10 VT: positive input signal P-ANG25StandardNBR
TPQ025WH25T2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar11 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator200 L/min4-+20 mAT: positive input signal P-ANG25StandardNBR
TPQ025WH25T2VS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar11 kgFPMn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedOthers3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator200 L/min4-+20 mAT: positive input signal P-ANG25StandardFPM
TPQ032WH25P2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar13 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator320 L/min0-&#177;10 VP: positive input signal A-TNG32StandardNBR
TPQ032WH25P2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar13 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator320 L/min4-+20 mAP: positive input signal A-TNG32StandardNBR
TPQ032WH25T2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar13 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator320 L/min0-&#177;10 VT: positive input signal P-ANG32StandardNBR
TPQ032WH25T2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar13 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator320 L/min4-+20 mAT: positive input signal P-ANG32StandardNBR
TPQ040WH25P2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar15 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min0-&#177;10 VP: positive input signal A-TNG40StandardNBR
TPQ040WH25P2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar15 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min4-+20 mAP: positive input signal A-TNG40StandardNBR
TPQ040WH25P2VB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar15 kgFPMn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedOthers3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min0-&#177;10 VP: positive input signal A-TNG40StandardFPM
TPQ040WH25T2HB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar15 kgFor HFC Fluidsn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedWater Glycol3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min0-&#177;10 VT: positive input signal P-ANG40Standardfor HFC fluid
TPQ040WH25T2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar15 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min0-&#177;10 VT: positive input signal P-ANG40StandardNBR
TPQ040WH25T2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar15 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min4-+20 mAT: positive input signal P-ANG40StandardNBR
TPQ040WH25T2VB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar15 kgFPMn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedOthers3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator550 L/min0-&#177;10 VT: positive input signal P-ANG40StandardFPM
TPQ050WH25P2NB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar26 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator800 L/min0-&#177;10 VP: positive input signal A-TNG50StandardNBR
TPQ050WH25P2NS0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar26 kgNBRn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedHydraulic Oil According to DIN 515243-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator800 L/min4-+20 mAP: positive input signal A-TNG50StandardNBR
TPQ050WH25P2VB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position P-A350 bar26 kgFPMn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedOthers3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator800 L/min0-&#177;10 VP: positive input signal A-TNG50StandardFPM
TPQ050WH25T2HB0
Backordered
POR
High Response for Controlled Applications50 &#176;CHigh-response ValveBasic Position A-T350 bar26 kgFor HFC Fluidsn/aSlip-in CartridgeSteelOnboard50 &#176;C-20 &#176;CUnrestrictedWater Glycol3-WayPilotIndustrial Systems Division Europe-20 &#176;CLinearExternal/externaln/aVCD-actuator800 L/min0-&#177;10 VT: positive input signal P-ANG50Standardfor HFC fluid

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains