Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

Picture for category Air-Oil Unit Model:AHU2-063 (Convertor Capacity 0.16~1.6L)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The AHU2 series is an Air-Oil Unit that converts pneumatic pressure into hydraulic control for constant speed control and arbitrary stop. Combinations such as those with flow control valves, those with throttle valves, and converters only are possible. It exerts more power when used in combination with our low-pressure hydraulic cylinder.


Markets:

・General Industry

・Machine Tools


Applications:

・General Industry

・Factory Automation

・Machine Tools


Features/Benefits:

・Because of hydraulic control, speed control is easy.

・With flow control, throttle, skip and stop valve, etc., select according to the application.

・The converter capacity is 0.16 to 20L.

・Some types are available with a switch.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Operating PressureDivisionFor Fluid TypeOperating TemperatureProof PressureProduct StylePilot Port SizePilot Pressure RatioLiquid Inlet Port SizeSupply Air Inlet Port SizeMinimum Opening PressureOptional AccessoriesSensor typeSensor ConnectionInput VoltageDiameterMaximum Flow Rate (lpm)Assembled Combined Valve TypeAssembled Control Valve TypeCapacity
H3FG00015879
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/ano sensorno sensorAC200V 50/60Hz63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015880
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a1 sensorZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015881
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a2 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015882
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a3 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015883
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a4 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)AC200V 50/60Hz63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015884
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/ano sensorno sensorDC24V63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015885
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a1 sensorZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015886
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a2 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015887
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a3 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015888
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a4 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)DC24V63 mm40Normal Open Skip ValveThrottle control(Meter-in control)1 L
H3FG00015889
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/ano sensorno sensorN/A63 mm40Without valveThrottle control(Meter-out control)1 L
H3FG00015890
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a1 sensorZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-out control)1 L
H3FG00015891
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a2 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-out control)1 L
H3FG00015892
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a3 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-out control)1 L
H3FG00015893
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a4 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-out control)1 L
H3FG00015894
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/ano sensorno sensorN/A63 mm40Without valveThrottle control(Meter-in control)1 L
H3FG00015895
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a1 sensorZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-in control)1 L
H3FG00015896
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a2 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-in control)1 L
H3FG00015897
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a3 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-in control)1 L
H3FG00015898
Backordered
POR
1 MPaTAIYO DivisionPetroleum-based Fluid-5 ~+50 °C (No freezing)1.5 MPaAir-Oil converterRc1/80.3xMain pressure+0.25MPa to 0.7MPaRc1/2Rc3/80.05 MPan/a4 sensorsZR3 (with contact, With lamp, Upper wiring, w/1.5 m cord)N/A63 mm40Without valveThrottle control(Meter-in control)1 L

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains