*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Division | Maximum Operating Pressure | For Fluid Type | Proof Pressure | Product Style | Minimum Opening Pressure | Pilot Port Size | Pilot Pressure Ratio | Operating Temperature | Liquid Inlet Port Size | Supply Air Inlet Port Size | Input Voltage | Assembled Control Valve Type | Assembled Combined Valve Type | Capacity | Diameter | Optional Accessories | Maximum Flow Rate (lpm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
H3FG00016539 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016540 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016541 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016542 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016543 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016544 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016545 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016546 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016547 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-in control) | Nomal Close Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016548 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016549 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016550 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016551 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016552 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016553 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC200V 50/60Hz | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016554 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016555 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 | |
H3FG00016556 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | DC24V | Flow control(Meter-out control) | Normal Open Stop Valve | 1 L | 100 mm | Lead wire | 85 | |
H3FG00016557 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket type | 85 | |
H3FG00016558 | Backordered | POR | Automation Division Japan - TAIYO | 1 MPa | Petroleum-based Fluid | 1.5 MPa | Air-Oil converter | 0.2 MPa | Rc1/4 | 0.2 to 0.7 MPa + 0.4 x Main Pressure | -5 to 50 °C (No freezing) | Rc1 | Rc1/2 | AC100V 50/60Hz | Flow control(Meter-in control) | Normal Open Stop Valve | 1 L | 100 mm | DIN socket with lamp | 85 |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.