• Availability & Price
  • Search SKU
Filter by attributes
  • Brand
  • Connection Type
  • Depth
  • Division
  • Height
  • Materials of Construction
  • Maximum Ambient Temperature
  • Maximum Flow Rate
  • Maximum Flow Rate (m³/h)
  • Maximum Operating Pressure
More Filters...

AK 120-600 Series Activated Carbon Adsorber

Picture for category AK 120-600 Series Activated Carbon Adsorber

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker Zander AK 120-600 range of activated carbon adsorbers are designed to purify pre-dried industrial compressed air down to a remaining oil content of 0,003mg/m³. The units can be installed free-standing or on a frame. They come equipped with oil indicator and pressure gauge and are capable of volume flows up to 6100 m³/h in a system operating at 7 barg (100 psig). Matching pre- and after-filters have to be ordered separately.

Features
• Volume flows up to 6100 m³/h @ 7 barg (100 psig)

• Maximum operating pressure 10 barg (145 psig)

• Oil indicator, pressure gauge and after-filter included

Operation
Pre-dried compressed air flows from top to bottom through a single vessel containing activated carbon. Any remaining oil aerosols and oil vapours including odours and tastes are removed by the active surface area of the highly porous activated carbon to produce high quality, clean compressed air. Using an oil-indicator tube, quality checks can be carried out periodically.

Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

Please note: The lifetime of the activated carbon filling can vary and is dependent on the contamination type and quantity and also on the humidity of the compressed air.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating PressureMaximum Ambient TemperatureMaximum Operating TemperatureMinimum Operating TemperatureWeightMaximum Flow RateBrandDepthWidthHeightProduct TypeConnection TypeSpecifications MetMaterials of ConstructionMinimum Operating PressureMinimum Ambient TemperaturePort SizeMaximum Flow Rate (m³/h)
A120/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA10 barg50 °C122 °F25 °C235 kg706.30 CFM at 7 bar(g)Zander840 mm500 mm2070 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR72.52 psig1.5 °CDN501200 @ 7 bar(g)
A150/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA145.04 psig50 °C122 °F25 °C275 kg912.30 CFM at 7 bar(g)Zander900 mm500 mm2110 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR72.52 psig34.7 °FDN651550 @ 7 bar(g)
A200/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA145.04 psig122 °F122 °F77 °F340 kg1177.16 CFM at 7 bargZander990 mm650 mm2150 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR5 barg34.7 °FDN652000 @ 7 bar(g)
A250/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA145.04 psig122 °F50 °C25 °C385 kg1471.45 CFM at 7 bargZander1040 mm650 mm2210 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR5 barg1.5 °CDN802500 @ 7 bar(g)
A300/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA145.04 psig50 °C122 °F77 °F440 kg1765.74 CFM at 7 bargZander1100 mm720 mm2230 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR72.52 psig34.7 °FDN803000 @ 7 bar(g)
A380/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA10 barg122 °F122 °F25 °C520 kg2236.61 CFM at 7 bargZander1200 mm850 mm2340 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR5 barg34.7 °FDN1003800 @ 7 bar(g)
A500/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA10 barg122 °F50 °C25 °C650 kg2854.62 CFM at 7 bar(g)Zander1250 mm860 mm2640 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR72.52 psig1.5 °CDN1004850 @ 7 bar(g)
A600/10A1-F
Backordered
POR
Gas Separation and Filtration Division EMEA10 barg50 °C122 °F25 °C950 kg3590.35 CFM at 7 bargZander1150 mm960 mm2820 mmActivated Carbon AdsorberFlangedPED, others on requestVessel & Piping: Steel, Seals: NBR5 barg34.7 °FDN1256100 @ 7 bar(g)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains