• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature
  • Application
  • Brand
  • Compatible After Filter
  • Compatible Prefilter
  • Connection Type
  • Depth
  • Division
  • Electrical Requirements
  • Flow Rate
More Filters...

BAM Breathing Air System

Picture for category BAM Breathing Air System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Hazardous vapours, gases and fumes can be released at various stages within manufacturing applications. Whether the risk is from noxious fumes, particulate or contamination from a compressed air system, effective respiratory protection for the user is essential.

In compressed air fed systems, ambient air is drawn into the compressor, therefore any contaminants present in the ambient air, plus those introduced by the compressor itself, will be present unless removed by a purification system.

The Parker BAM breathing system consists of seven purification stages mounted on a portable skid for high-capacity multiple personnel breathing air applications.

At the inlet, a water separator removes bulk water, followed immediately by two OIL-X coalescing filters to reduce oil and water content. The fourth stage of purification is an adsorption dryer that reduces the water vapour content of the compressed air (to -40°C pdp) and CO2 to below the legal permissible limits. Downstream of the adsorption dryer an activated carbon filter then reduces oil vapour and odours, then a catalyst filter reduces carbon monoxide to carbon dioxide, again, to below the legal limits. A final dust filter captures any particulates carried over from the adsorption materials.

Features
• 7 Purification stages

• CO monitor fitted as standard

• CO and CO2 reduction to below legal permissible limits

• Air quality 3rd party independently certified, better than the European Pharmacopoeia standard

• Energy management system fitted as standard

• Modular, space saving design

• Use with any compressed air supply

Please note this product is currently only available in Europe.

Sizing and Selection
To ensure quoted air purity performance is met, a breathing air system must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyDivisionIndustryApplicationSpecifications MetDepthWidthHeightWeightISO GradeNoise LevelProduct TypeProduct SeriesConnection TypeOperating PressurePressure Dew PointAmbient TemperatureCompatible PrefilterOperating TemperatureCompatible After FilterElectrical RequirementsIngress Protection RatingPort SizeFlow Rate
BAM10
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II1655.0 mm1260.0 mm70.7 inch600 kgISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT58 to 190 psig-40 °F131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2 inch408 m³/h @ 7 barg (240 cfm @ 102 psig)
BAM20
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II65.2 inch49.6 inch1797.0 mm1543 lbISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT4 to 13 barg-40 °C131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2 inch612 m³/h @ 7 barg (360 cfm @ 102 psig)
BAM30
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II1655.0 mm1260.0 mm80.4 inch1763 lbISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT58 to 190 psig-40.0 °F131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2 inch795 m³/h @ 7 barg (450cfm @ 102 psig)
BAM40
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II65.2 inch49.6 inch80.4 inch900 kgISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT58 to 190 psig-40.0 °F131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2 inch1020 m³/h @ 7 barg (600 cfm @ 102 psig)
BAM50
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II76.8 inch49.6 inch80.4 inch1100 kgISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT58 to 190 psig-40 °C131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2½ inch1275 m³/h @ 7 barg (750 cfm @ 102 psig)
BAM70
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAAgriculture, Aviation, Chemical, Construction, Electrical Utilities, Fire Service, Food & Beverage Production, Gas Utilities, Hazmat, Iron / Steel Production, Manufacturing, Marine / Shipyard, Mining, Nuclear, Oil & Gas Production, Petrochemical, Pulp &• Tank cleaning<br/>• Spray painting<br/>• Asbestos removal<br/>• Shot blasting<br/>• Tunnelling<br/>• Confined spaces<br/>• Welding<br/>• DemolitionPED 2014/68/EU Fluid Group II76.8 inch49.6 inch2042.0 mm3086 lbISO8573-1:2010 Class 1.2.1< 75 dBABreathing Air PurifierBAMBSPP or NPT58 to 190 psig-40.0 °F131.0 °F MaximumOIL-X Grades AO and AA Coalescing (Included)41 to 95 °FOIL-X Grades AO and AA Dry Particulate (Included)<br/>OIL-X OVR Oil Vapour Reduction (Included)Standard:<br/>85 - 265 V 1ph 50/60HzIP55 Indoor Use Only2½ inch1785 m³/h @ 7 barg (1050 cfm @ 102 psig)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains