Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

Picture for category Blower Purge Heat Reactivated Desiccant Air Dryer -TWB Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.
Parker Airtek TWB Series Blower Purge Desiccant Air Dryers will effectively remove these contaminants.  The traditional adsorption principle used in this design is simple, robust and flexible using compressed air for regeneration therefore eliminating any need for an outside energy supply.
Continuous drying is accomplished by the operation of two desiccant towers.  

Compressed air is dried through one tower while the other desiccant tower is being regenerated.  The regeneration heating cycle of the desiccant is accomplished using a hot air flow delivered by an atmospheric blower and external electric heater (other means of heating are optional).  The regeneration cooling cycle is performed using a small flow of dry compressed air taken from the blower purge dryer outlet to ensure dewpoint performance. High levels of reliability are achieved by the use of proven engineering technology and components.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all operational information
*Optional equipment
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceOptional AccessoriesDepthWeightMinimum Ambient TemperatureCompatible After Filter ElementPurge Pressure RateMinimum Operating TemperatureConnection TypeCompatible After FilterCompatible PrefilterHeightMaximum Flow RateDivisionWidthMaximum Operating PressureBrandMaximum Operating TemperatureCompatible Prefilter ElementProduct TypeMinimum Operating PressureMaximum Inlet Pressure RatingMaximum Ambient TemperatureInstalled Condensate Drain TypeMaximum Flow Rate (cfm)Pressure Dew Point (F)Electrical Requirements
TWB1001FY41NNN
Backordered
POR
Pre and After Filtration41 inch5700 lb40 °FJE-FC0800-HT050 °F3" FlgJC1000-FHJC1000-C102 inch1699 m3/hourIndustrial Gas Filtration and Generation Division74 inch150 psiAirtek120 °FJE-CC0800Compressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain1000-40460V/3Ph/60Hz
TWB1201FY41NNN
Backordered
POR
Pre and After Filtration41 inch6300 lb40 °FJAE4-FH050 °F3" FlgJLA1800-FHJLA1603-C113 inch2038 m3/hourIndustrial Gas Filtration and Generation Division74 inch150 psiAirtek120 °FJAE4-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain1200-40460V/3Ph/60Hz
TWB1501FY41NNN
Backordered
POR
Pre and After Filtration60 inch7165 lb40 °FJAE4-FH050 °F3" FlgJLA1800-FHJLA1603-C113 inch2548 m3/hourIndustrial Gas Filtration and Generation Division78 inch150 psiAirtek120 °F(2) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain1500-40460V/3Ph/60Hz
TWB2001FY41NNN
Backordered
POR
Pre and After Filtration66 inch9850 lb40 °F(2) JAE3-FH050 °F4" FlgJLA2600-FHJLA2100-C112 inch3398 m3/hourIndustrial Gas Filtration and Generation Division114 inch135 psiAirtek120 °F(3) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain2000-40460V/3Ph/60Hz
TWB201BY41NNN
Backordered
POR
Pre and After Filtration39 inch1500 lb50 °FJE-FC0350-HT050 °F1 1/2” NPTJC0250-FHJC0250-C85 inch340 m3/hourIndustrial Gas Filtration and Generation Division56 inch150 psiAirtek120 °FJE-CC0350Blower Purge80 psi100 psi120 °FTimes Solenoid Drain200-40460V/3Ph/60Hz
TWB2601FY41NNN
Backordered
POR
Pre and After Filtration72 inch12210 lb40 °F(2) JAE3-FH050 °F4" FlgJLA2600-FHJLA3200-C112 inch4417 m3/hourIndustrial Gas Filtration and Generation Division132 inch135 psiAirtek120 °F(4) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain2600-40460V/3Ph/60Hz
TWB3001FY41NNN
Backordered
POR
Pre and After Filtration72 inch12650 lb40 °F(3) JAE3-FH050 °F6" FlgJLA3506-FHJLA3206-C112 inch5097 m3/hourIndustrial Gas Filtration and Generation Division132 inch135 psiAirtek120 °F(4) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain3000-40460V/3Ph/60Hz
TWB301BY41NNN
Backordered
POR
Pre and After Filtration27 inch1900 lb50 °FJE-FC0350-HT050 °F1 1/2" NPTJC0350-FHJC0350-C87 inch510 m3/hourIndustrial Gas Filtration and Generation Division43 inch150 psiAirtek120 °FJE-CC0350Compressed Air – Desiccant80 psi100 psi120 °FTimes Solenoid Drain300-40460V/3Ph/60Hz
TWB4001FY41NNN
Backordered
POR
Pre and After Filtration84 inch18910 lb40 °F(4) JAE3-FH050 °F6" FlgJLA5306-FHJLA4500-C114 inch6796 m3/hourIndustrial Gas Filtration and Generation Division168 inch135 psiAirtek120 °F(6) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain4000-40460V/3Ph/60Hz
TWB401BY41NNN
Backordered
POR
Pre and After Filtration27 inch2180 lb40 °FJE-FC0450-HT050 °F2" NPTJC0450-FHJC0450-C88 inch680 m3/hourIndustrial Gas Filtration and Generation Division47 inch150 psiAirtek120 °FJE-CC0450Blower Purge80 psi100 psi120 °FTimes Solenoid Drain400-40460V/3Ph/60Hz
TWB5001FY41NNN
Backordered
POR
Pre and After Filtration92 inch21590 lb40 °F(4) JAE3-FH050 °F6" FlgJLA5306-FHJLA5000-C114 inch8495 m3/hourIndustrial Gas Filtration and Generation Division156 inch135 psiAirtek120 °F(7) JAE3-CCompressed Air – Desiccant80 psi100 psi120 °FDemand Solenoid Drain5000-40460V/3Ph/60Hz
TWB501BY41NNN
Backordered
POR
Pre and After Filtration27 inch2840 lb40 °FJE-FC0625-HT050 °F2" NPTJC0625-FHJC0625-C89 inch850 m3/hourIndustrial Gas Filtration and Generation Division50 inch150 psiAirtek120 °FJE-CC0625Compressed Air – Desiccant80 psi100 psi120 °FTimes Solenoid Drain500-40460V/3Ph/60Hz
TWB6001FY41NNN
Backordered
POR
Pre and After Filtration92 inch24890 lb40 °F(5) JAE3-FH050 °F6" FlgJLA6000-FHJLA7206-C112 inch10194 m3/hourIndustrial Gas Filtration and Generation Division146 inch135 psiAirtek120 °F(9) JAE3-CBlower Purge80 psi100 psi120 °FDemand Solenoid Drain6000-40460V/3Ph/60Hz
TWB601BY41NNN
Backordered
POR
Pre and After Filtration28 inch3420 lb40 °FJE-FC0625-HT050 °F2" NPTJC0625-FHJC0625-C92 inch1019 m3/hourIndustrial Gas Filtration and Generation Division52 inch150 psiAirtek120 °FJE-CC0625Blower Purge80 psi100 psi120 °FTimes Solenoid Drain600-40460V/3Ph/60Hz
TWB7501FY41NNN
Backordered
POR
Pre and After FiltrationConsult Factoryn/a Contact us40 °FConsult Factory050 °F8" FlgConsult FactoryConsult FactoryConsult Factory inch12743 m3/hourIndustrial Gas Filtration and Generation DivisionConsult Factory inch135 psiAirtek120 °FConsult FactoryBlower Purge80 psi100 psi120 °FDemand Solenoid Drain7500-40460V/3Ph/60Hz
TWB801BY41NNN
Backordered
POR
Pre and After Filtration35 inch4490 lb40 °FJE-FC0800-HT050 °F2" NPTJC0800-FHJC0800-C93 inch1359 m3/hourIndustrial Gas Filtration and Generation Division64 inch150 psiAirtek120 °FJE-CC0800Blower Purge80 psi100 psi120 °FTimes Solenoid Drain800-40460V/3Ph/60Hz

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains