• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature
  • Application
  • Brand
  • Connection Type
  • Depth
  • Division
  • Division
  • Filter Included
  • Flow Rate
  • Height
More Filters...

CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

Picture for category CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyDivisionDivisionIngress Protection RatingOperating TemperatureWeightNoise LevelAmbient TemperatureProduct SeriesDepthWidthHeightProduct TypeIndustryApplicationProduct StyleOperating PressureSpecifications MetFilter IncludedPower Supply VoltageConnection TypePort SizeFlow RateISO GradePressure Dew PointPump Type
CDASHL100-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F235 kg< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch687.0 mm1647.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2"408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL100-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)235 Kg<br/>(518 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60HzNPT2"408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL100-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C235 kg< 75 dBA131.0 °F MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550.0 mm27 inch1647.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2"286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL100-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)235 Kg<br/>(518 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60HzNPT2"286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL110-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F696 lb< 75 dBA131.0 °F MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550.0 mm33.7 inch74.5 inchCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2"612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL110-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)316 Kg<br/>(696 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60HzNPT2"612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL110-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F696 lb< 75 dBA131.0 °F MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550.0 mm33.7 inch74.5 inchCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2"428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL110-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)316 Kg<br/>(696 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60HzNPT2"428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL120-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C355 kg< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch33.7 inch1647.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL120-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)355 Kg<br/>(782 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL120-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C782 lb< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550.0 mm33.7 inch1647.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL120-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)355 Kg<br/>(782 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL130-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F450 kg< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch1025.0 mm74.5 inchCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"1020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL130-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)450 Kg<br/>(992 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"1020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL130-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F992 lb< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch1025.0 mm1892.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL130-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)450 Kg<br/>(992 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL140-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F543 kg< 75 dBA55.0 °C MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch1194.0 mm1892.0 mmCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"1275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL140-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)543 Kg<br/>(1197 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"1275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL140-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C543 kg< 75 dBA131.0 °F MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)21.7 inch47.0 inch74.5 inchCompressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60HzBSPP2½"893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A
CDASHL140-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)543 Kg<br/>(1197 lbs)<75 dB(A)55°C (131°F) MaximumCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)Compressed Air Dryer with Filtration• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60HzNPT2½"893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)Class 2.1.2-70°C (-100°F)N/A

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains