FMD Membrane Dryer Features:
• Designed for point-of-use applications
• Pressures to 150 PSIG
• No moving parts
• Drying efficiency down to -40°F pressure dewpoint
• Quiet, Continuous operation • No electricity needed • Low pressure drop • Hollow fiber technology

FMD Membrane Dryer Advantages:
• Nothing towear out
• Can be installed anywhere
• Lightweight
• No waiting for media changeouts
• Differential pressure indicator indicates when filter elements should be changed • No electricity, no U.L. approval required, no refrigerants, and low dewpoints • Only water vapor molecules are allowed to pass through the hollow fiber walls
FMDMembrane Dryer Benefits:
• Less downtime
• Perfect for poin-of-use applications
• Ease of installation
• Dryer protection insurance
• Low operating cost, OEM cost savings, Environmentally friendly, prevents freeezing • Dryers can be used in medical, dental and breathing air applications

Desiccant Types available; (Desiccant sold separately)

• Silica Gel -(FSGM100-1 = 5 lb can) 100 % indicating silica gel provides maximum moisture adsorption and dewpoints down to -40°F.

• Molecular Sieve -(FMS100-1 = 5 lb can) molecular sieves are crystaline, metallic aluminum silicates. The type 4A offers exceptional water vapor adsorption characteristics. Molecular sieves are more effective than silica gel at removing water vapor at elevated inlet temperatures. Dewpoints are attainable to -40°F.

How do they work?

The water vapor in the compressed air is removed by the principal of selective permeation through a membrane. The membrane module consists of bundles of hollow membrane fibers, each permeable to water vapor. As the compressed air passes through the center of these fibers, water vapor permeates through the walls of the fibers. A small portion of the dry air (purge air) is directed along the outside of each hollow fiber, carrying away the moisture-laden air whcih is then exhausted to room atmosphere. The remainder of the dry air is piped to the application.

In all cases when a Grade 10 prefilter and a Grade 6 coalescer are installed upstream on the dryer module, 99.9985% removal of oil aerosols and mists can be obtained. Based on a 40 ppm inlet.



Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Operating PressureCompatible Prefilter ElementWidthBrandHeightMaximum Operating TemperatureDivisionConnection TypeWeightPurge Rate (SCFM)Port Connection (inch)Dewpoint (F)
FMD35-006
Backordered
POR
4.1 to 10.3 barg6HM06-01314 cmFinite14.5 inch4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT0.38 kg0.25 @ 100 PSI1/4"35
FMD35-015
Backordered
POR
60 to 150 psig6HM06-0136.5 inchFinite38.1 cm4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT1.9 lb0.5 @ 100 PSI1/4"35
FMD35-060
Backordered
POR
60 to 150 psig6C10-02510 inchFinite55.88 cm4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT5.2 lb1.5 @ 100 PSI1/4"35
FMD35-100
Backordered
POR
4.1 to 10.3 barg6C10-02511.5 inchFinite22 inch4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT3.22 kg3.5 @ 100 PSI1/2"35
FMD35-400
Backordered
POR
60 to 150 psig6C10-05014 inchFinite96.52 cm4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT8.57 kg6.0 @ 100 PSI1/2"35
FMD40-001
Backordered
POR
60 to 150 psig6HM06-0135.5 inchFinite36.83 cm40 to 100 °FIndustrial Gas Filtration and Generation DivisionNPT0.7 lb0.25 @ 100 PSI1/4"-40
FMD40-002
Backordered
POR
60 to 150 psig6HM06-0136.5 inchFinite38.1 cm4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT1.9 lb0.2 @ 100 PSI1/4"-40
FMD40-020
Backordered
POR
4.1 to 10.3 barg6C10-02510 inchFinite22 inch4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT2.36 kg0.5 @ 100 PSI1/4"-40
FMD40-050
Backordered
POR
4.1 to 10.3 barg6C10-02514 inchFinite26 inch40 to 100 °FIndustrial Gas Filtration and Generation DivisionNPT3.22 kg2.0 @ 100 PSI1/2"-40
FMD40-100
Backordered
POR
60 to 150 psig6C10-05035.56 cmFinite96.52 cm4.4 to 37.8 °CIndustrial Gas Filtration and Generation DivisionNPT18.9 lb2.5 @ 100 PSI1/2"-40