• Availability & Price
  • Search SKU
Filter by attributes
  • Aux Supply Input Voltage
  • Brand
  • Communication Interface
  • Compatible Feedback Device
  • Compatible Motor Type
  • Continuous Output Current Rating
  • Division
  • Drive Axis Type
  • Frame Size
  • Input Voltage
More Filters...

DC Motor Speed Controller - DC590+ Series(AP)

Picture for category DC Motor Speed Controller - DC590+ Series(AP)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Integrator series is a single family of both AC drives (AC690+) and DC drives (DC590+) that provides the benefits of common programming, set-up and communication across both technologies. The DC590+ Integrator series highly advanced DC drive meets the demands of the most complex motor control applications. Extensive application software (including winder control as standard) together with Function Block Programming and configurable I/O creates a total drive system in a single module.

Options :
· Programmable Keypad 6901
· Technology Box for Communications (Profibus-DP, DeviceNet, CANopen, LINK, LonWorks, EI Bisynch/RS422/RS485, Modbus RTU)
· Speed Feedback Technology Box (analogue Tachometer, encoder microtach for acrylic F.O., microtach for glass F.O.)
· EMC Filter- Industrial Ambience
· Line Reactors for European and North American markets (UL-CSA)
· Line Inductors for long motor leads
· 598+ and 599+ Stack Controller configuration available for retrofit of existing power stacks

Markets:
· Converting Machinery
· Plastics and Rubber Processing
· Wire and Cable
· Metallurgical equipment
· Primary Metal Refining/Process
· Pulp & Pape
· Factory Automation
· Automotive

Features and Benefits:
· Extremely simple set-up and programming
· Extremely Compact
· Removable Key Pad
· Motor Thermistor Input
· 598+ and 599+ Stack Controller configuration available for retrofit of existing power stacks

Applications:
· Printing
· Cable Machinery
· Film and Foil Lines
· Extrusion
· Mixers
· Annealing Lines
· Slitting Lines
· Metal Processing
· Test Stands
· Dynanometers

Macro Function Blocks:
· Open-loop winder control
· Winder control - loadcell/dancer
· Section control
· Math functions
· Embedded controller functions

Standards:
The DC590+ Series DC drives listed on this page meet the following standards when installed in accordance with the relevant product manual:
· EMC Compatibility : CE Marked in accordance with 2004/108/EC (EMC Directive)
· Europe : This product conforms with the Low Voltage Directive 2006/95/EC
· Safety : EN61800-5/2003 (when fitted inside a cubicle)
· North America/Canada : *Complies with the requirements of UL508C and CSA22.2 #14 as an open-type drive (*only applicable to frame sizes 1-4)
· Overvoltage Category : Overvoltage Category III (3-phase supply) / Overvoltage Category II (auxiliary supply)
· Pollution Degree : II (non-conductive pollution, except for temporary condensation) for control electronics


Technical Specifications:
Power Supply:
Three Phase
110-220VAC±10 %, 50-60 Hz ± 5%
220-500VAC ± 10 %, 50-60 Hz ± 5%
500-690VAC ± 10 %, 50-60 Hz ± 5%

Output Armature Current Ratings:
15 - 1950A

Overload:
- for 15 to 270A drives : 150% for 30 sec / 200% for 10 sec
- for drives above 270A : refer to catalog or manual for details

Environment:
- for 15 to 165A drives : 0-45°C / 32-113°F
- for 180 to 270A drives : 0-35°C / 32-95°F
- for 380 to 1950A drives : 0-40°C / 32-104°F
Up to 500m ASL (derate 1% per 200m up to 5000m maximum)

Speed Feedback:
- Armature Voltage Feedback / - Tach Generator / - Encoder

Analog Inputs:
5 Total : 1 x 12 bit (plus sign), 4 x 10 bit (plus sign)
- 1x Speed Demand Setpoint (-10/0/+10V) / 4x Configurable

Analog Outputs:
3 Total : 10 bit
- 1x Armature Current Output (-10/0/+10V or 0-10V) / 2x Configurable

Digital Inputs:
9 Total : 24VDC (max 15mA)
- 1x Program Stop / 1x Coast Stop / 1x External Stop / 1x Start-Run / 5x Configurable

Digital Outputs:
3 Total : 24VDC / 100mA (short circuit protected)
- 3x Configurable

Reference Supplies:
- 1x- +10VDC / 1x -10VDC / 1x +24VDC

Power Bridge:
590+ - 4 Quadrant Regenerative : Dual Three Phase SCR bridges
591+ - 2 Quadrant Non-Regenerative : Single SCR bridge
Variable Field Control with SCR’s

Drive Protection:
- High energy MOV’s / - Heatsink overtemperature / - Instantaneous overcurrent
- Thyristor trigger failure / - Inverse time overcurrent / - Interline snubber network
- Field Failure / - Zero speed detection / - Speed feedback failure / - Stall protection
- Motor overtemperature / - Stall protection
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandDivisionDrive Axis TypeSpecifications MetFrame SizeProduct TypeProduct SeriesOperating TemperatureOutput PowerOverload RatingOperating AltitudeCompatible Motor TypeCompatible Feedback DeviceContinuous Output Current RatingCommunication InterfaceModes of ControlOption Board TypeAux Supply Input VoltageKeypad/User Interface OptionInput VoltageSpecial OptionOutput Current RatingSpeed Feedback Type
590P-53372542-A00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyOvervoltage Category III4DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 AControlNetFour Quadrant / RegenerativeN/A1*230VAC6901 keypad fitted3*220-500VACAirflow Kit725AArmature Voltage
590P-53372542-A00-U4W0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II4DC DriveDC5900 to 40 °C for 380-1950A drives (derate up to 55°C max.)1 to 1200 HP150 % for 30sup to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 ADeviceNetFour Quadrant / RegenerativeN/A1*230VAC6901 keypad fitted3*220-500VACAirflow Kit725AWire-ended Encoder
590P-53383042-A00-U0A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed4DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoArmature Voltage15 to 1950 ACANopenFour Quadrant / RegenerativeN/A1*230VACNone3*220-500VACAirflow Kit830AAnalog Tacho
590P-53383042-A00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II4DC DriveDC5900 to 40 °C for 380-1950A drives (derate up to 55°C max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 AControlNetFour Quadrant / RegenerativeN/A1*230VAC6901 keypad fitted3*220-500VACAirflow Kit830AAnalog Tacho
590P-53412560-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II6DC DriveDC5900 to 35 °C for 180-270A drives (derate up to 55°C max.)1 to 1200 HP150 % for 30sup to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone1250AAnalog Tacho
590P-53416060-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II6DC DriveDC5900 to 45 °C for 15-165A drives (derate up to 55°C max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 AControlNetFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone1600AAnalog Tacho
590P-53416060-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed6DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 AProfibusFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone1600AArmature Voltage
590P-53419560-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II6DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP150 % for 30sup to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone1950AAnalog Tacho
590P-53419560-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed6DC DriveDC59032 to 113 °F for 15-165A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 ALinkNetFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone1950AArmature Voltage
590P-63383042-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed4DC DriveDC5900 to 45 °C for 15-165A drives (derate up to 55°C max.)1 to 1200 HP150 % for 30sup to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*230VAC6901 keypad fitted3*380-600VACNone830AArmature Voltage
590P-73412560-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyOvervoltage Category III6DC DriveDC59032 to 113 °F for 15-165A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1250AAnalog Tacho
590P-73412560-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed6DC DriveDC5900 to 45 °C for 15-165A drives (derate up to 55°C max.)1 to 1200 HP150 % for 30sup to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1250AArmature Voltage
590P-73416060-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologycUL Listed6DC DriveDC5900 to 45 °C for 15-165A drives (derate up to 55°C max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 ARS232/RS485Four Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1600AAnalog Tacho
590P-73416060-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II6DC DriveDC59032 to 95 °F for 180-270A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 ADeviceNetFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1600AArmature Voltage
590P-73418560-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyUL Listed6DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 AProfibusFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1850AAnalog Tacho
590P-73418560-P00-U4V0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II6DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 AEthernet TCP/IPFour Quadrant / RegenerativeN/A1*115/230VAC6901 keypad fitted3*380-690VACNone1850AArmature Voltage
591P-53215010-P00-U0A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyOvervoltage Category III1DC DriveDC5900 to 35 °C for 180-270A drives (derate up to 55°C max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoTachometer15 to 1950 AModbusTwo Quadrant / Non-RegenerativeN/A1*115/230VACNone3*220-500VACNone15AAnalog Tacho
591P-53215010-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologycUL Listed1DC DriveDC5900 to 40 °C for 380-1950A drives (derate up to 55°C max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoArmature Voltage15 to 1950 AModbusTwo Quadrant / Non-RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone15AAnalog Tacho
591P-53235010-P00-U4A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II1DC DriveDC59032 to 104 °F for 380-1950A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoArmature Voltage15 to 1950 AControlNetTwo Quadrant / Non-RegenerativeN/A1*115/230VAC6901 keypad fitted3*220-500VACNone35AAnalog Tacho
591P-53240020-P00-U0A0
Backordered
POR
PARKERControl Division ChinaSingle Axis TechnologyPollution Degree II2DC DriveDC59032 to 95 °F for 180-270A drives (derate up to 131°F max.)1 to 1200 HP200 % for 10s (depending on drive output current, refer to manual for details)up to 500 m ASL (derate > 500m)DC Brushed ServoEncoder15 to 1950 AControlNetTwo Quadrant / Non-RegenerativeN/A1*115/230VACNone3*220-500VACNone40AAnalog Tacho

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains