• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Body Material
  • Connection 1 Tube Outside Diameter
  • Connection 2 Tube Outside Diameter
  • Division
  • For Fluid Type
  • Gripping Ring Material
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
More Filters...

Direct Buried Connectors

Picture for category Direct Buried Connectors

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The new Parker Legris direct buried connectors were developed to optimise installation and provide long-term integrity for underground FTTx* networks.

*FTTx: Fiber To The x = home, building, campus, etc

Features/Benefits:

- Optimised Installation

• Transparent: optic fibre ducts and correct tube connection can be seen and verified
• Patented ridged design for unsurpassed shock resistance
• No protection cap necessary
• 1 connector for 2 different wall thicknesses of the tubing (bridging possible between direct buried and direct install micro-tubing)
• Compact design and intuitive installation
• Pre-assembled safety clip to prevent risk of accidental disconnection
• High working pressure for increased blowing speed/distance

- Longevity & Reliability

• Tried-and-tested connection technology to ensure tensile strength and resistance to network expansion
• Perfect sealing IP68: full protection against particle ingress
• UL94: flame resistance for indoor installations
• Date coding to guarantee quality and traceability
• 100% leak-tested in production

Markets:

• Telecommunication
• Information Technology

Applications:

• Connector for FTTX Applications
• Air and Water Conveying
• Underground Networks
• Air Blowing
• Water Floating
• Heavy Duty Ducting

Technologies:

• Tube to tube connectors
• Pneumatic Fittings
• Instant Fittings
• Quick Fittings
• Optic fibre connectors

Technical Characteristics:

• Compatible fluids: Air, water
• Materials: HR polymer, stainless steel, technical polymer, NBR
• Pressure: 0 to 25 bar
• Temperature: -20°C to +80°C

Regulations:

• ISO 14743: Pneumatic fluid power, push-in connectors for thermoplastic tubes
• NF EN 50086-2-4 replaced by NF EN 61386-24: Standard relating to impact tests for buried systems
• UL94: Flame resistance
• IP68: Seepage resistance to water and dust
• Patent family FR2980999 (buried connectors)
• Patent family FR2924194 (safety clips)

Product Types:

• Equal and Unequal Tube-to-Tube Connector
• Equal and Unequal Tube-to-Tube Connector with Red Tamper-Proof Safety Clips
• End Cap
• End Cap with Red Tamper-Proof Safety Clip
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureQuantity per BoxWeightFor Fluid TypeGripping Ring MaterialVacuum Pressure RatingSeal MaterialSpecifications MetMaximum Operating PressureApplicationBody MaterialConnection 1 Tube Outside DiameterProduct StyleConnection 2 Tube Outside Diameter
6270 07 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.006 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)NF EN 50086-2-4. Replaced by NF EN 61386-24: Standard Relating to Impact Tests for Buried Systems25 bargUnderground NetworksHR Polymer7 mm (O.D.)Direct Buried Equal and Inequal7 mm (O.D.)
6270 07 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.007 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)Patent Family25 bargMicro-TubingHR Polymer7 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips7 mm (O.D.)
6270 08 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.006 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)UL94: Flame Resistance25 bargUnderground NetworksHR Polymer8 mm (O.D.)Direct Buried Equal and Inequal8 mm (O.D.)
6270 08 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.007 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargUnderground NetworksHR Polymer8 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips8 mm (O.D.)
6270 10 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.009 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)NF: EN 50086-2-4 (Replaced by NF EN 61386-24: Standard Relating to Impact Tests for Buried Systems)25 bargUnderground NetworksHR Polymer10 mm (O.D.)Direct Buried Equal and Inequal10 mm (O.D.)
6270 10 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.011 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)IP68: Seepage Resistance to Water and Dust, Patent Fam25 bargWater FloatingHR Polymer10 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips10 mm (O.D.)
6270 10 12
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.01 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)NF: EN 50086-2-4 (Replaced by NF EN 61386-24: Standard Relating to Impact Tests for Buried Systems)25 bargMicro-TubingHR Polymer10 mm (O.D.)Direct Buried Equal and Inequal12 mm (O.D.)
6270 10 12 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.026 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)UL94: Flame Resistance25 bargAir BlowingHR Polymer10 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips12 mm (O.D.)
6270 12 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.009 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO 14743: Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes25 bargUnderground NetworksHR Polymer12 mm (O.D.)Direct Buried Equal and Inequal12 mm (O.D.)
6270 12 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.017 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargHeavy Duty DuctingHR Polymer12 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips12 mm (O.D.)
6270 12 14
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C250.022 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargAir BlowingHR Polymer12 mm (O.D.)Direct Buried Equal and Inequal14 mm (O.D.)
6270 12 14 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C250.031 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)UL94: Flame Resistance25 bargMicro-TubingHR Polymer12 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips14 mm (O.D.)
6270 14 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C250.022 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)Patent Family25 bargUnderground NetworksHR Polymer14 mm (O.D.)Direct Buried Equal and Inequal14 mm (O.D.)
6270 14 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C250.023 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)NF EN 50086-2-4. Replaced by NF EN 61386-24: Standard Relating to Impact Tests for Buried Systems25 bargWater FloatingHR Polymer14 mm (O.D.)Direct Buried Equal and Inequal with Safety Clips14 mm (O.D.)
6273 07 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.002 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO 14743: Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes25 bargMicro-TubingHR Polymer7 mm (O.D.)Direct Buried End Cap
6273 07 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.003 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)NF: EN 50086-2-4 (Replaced by NF EN 61386-24: Standard Relating to Impact Tests for Buried Systems)25 bargWater FloatingHR Polymer7 mm (O.D.)Direct Buried End Cap with Safety Clips
6273 08 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.002 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargMicro-TubingHR Polymer8 mm (O.D.)Direct Buried End Cap
6273 08 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C1000.003 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargWater FloatingHR Polymer8 mm (O.D.)Direct Buried End Cap with Safety Clips
6273 10 00
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.003 kgWaterSTAINLESS STEEL755 mm-HgNBR (O-Ring)IP68: Seepage Resistance to Water and Dust, Patent Fam25 bargMicro-TubingHR Polymer10 mm (O.D.)Direct Buried End Cap
6273 10 00 03
Backordered
POR
Low Pressure Connectors Europe Division80 °C-20 °C500.005 kgAirSTAINLESS STEEL755 mm-HgNBR (O-Ring)ISO: 14743 (Pneumatic Fluid Power, Push-in Connectors for Thermoplastic Tubes)25 bargUnderground NetworksHR Polymer10 mm (O.D.)Direct Buried End Cap with Safety Clips

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains