*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The direct operated valves D1FB (NG06) and D3FB (NG10) are universally applicable, provide high repeatability and low hysteresis for an improved process accuracy.
D1FB and D3FB represent Parker's experience in proportional DC valve technology. They are sutiable for use in applications which require a speed control. Both can be ordered with spool/sleeve design (D*FB*0) for maximum precision as well as spool/body design (D*FB*3) for high nominal flow. The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWD00A-400.
The D1FB*EE series with explosion proof solenoids is based on the standard D1FB series. The specific solenoid design allows the usage in hazardous environments. The explosion proof class is Ex e mb II T4 Gb for use in zone 1 and 2 (conform to ATEX). Additionally the solenoids have IECEx conformity.
Markets:
• Industrial
• Machine tools
• Rubber & tire processing
Features/Benefits:
• Spool/sleeve and spool/body design - provides versatile applications, for maximum precision or high nominal flow
• Manual override - allows to actuate the valve without current
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High level of dynamics and flows - optimized process speed
• Short delivery time - no storage necessary
• D1FB*EE only: optional coil to permit ambient temperature up to +60 °C, modification XG371
Applications:
• Suitable for various hydraulic applications
• Machine tool
• Tire presses
Action | SKU | Availability | Price | Function | Maximum Flow Rate | Weight | Division | Maximum Operating Temperature | Minimum Operating Temperature | Maximum Operating Pressure | Mounting Type | Seal Material | Body Material | Operation Type | Mounting Position | Actuation Type | For Fluid Type | Product Series | Pressure Differential | Electronics Type | Minimum Kinematic Viscosity | Hysteresis | Maximum Fluid Temperature | Minimum Fluid Temperature | Maximum Ambient Temperature | Minimum Ambient Temperature | Maximum Kinematic Viscosity | Ingress Protection Rating | Filter Efficiency Rating | Leak Rate | Port Connection | Spool Position | Spool Type | Flow Rate | Spool Code | Spool Design | Solenoid Option | Solenoid Connection |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D1FBB31FC0NJW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 12 / 6 L/MIN | B31F | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBB31FC0NKE0EE | Backordered | POR | 3-Way | n/a | 3.5 kg | Industrial Systems Division Europe | 40 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 12 / 6 L/MIN | B31F | Spool/sleeve | 12 V / 2.3 A | Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity | |
D1FBB31FC0NMW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 12 / 6 L/MIN | B31F | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBB31FE0NJW0 | Backordered | POR | 2-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a | Overlap | 12 / 6 L/MIN | B31F | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBB31HC0NJW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 20 / 10 L/MIN | B31H | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBB31HC0NKW3 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <6 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <60 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 20 / 10 L/MIN | B31H | Spool/body | 12 V / 2.2 A | Connector as per EN 175301-803 | |
D1FBB31HC0NMW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 20 / 10 L/MIN | B31H | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBB31HE0NMW0 | Backordered | POR | 2-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a | Overlap | 20 / 10 L/MIN | B31H | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBB32FC0NJW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 12 / 6 L/MIN | B32F | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBB32FC0NMW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 12 / 6 L/MIN | B32F | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBB32HC0NJW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 20 / 10 L/MIN | B32H | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBB32HC0NMW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 20 / 10 L/MIN | B32H | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBB32KC0NJE3EE | Backordered | POR | 3-Way | n/a | 3.5 kg | Hydraulic Valve Systems Division Europe | 40 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <6 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <60 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 30 / 15 L/MIN | B32K | Spool/body | 24 V / 1.15 A | Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity | |
D1FBB32KC0NJJ3 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <6 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <60 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 30 / 15 L/MIN | B32K | Spool/body | 24 V / 1.1 A | Connector DT04-2P | |
D1FBB32KC0NJW3 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <6 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <60 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 30 / 15 L/MIN | B32K | Spool/body | 24 V / 1.1 A | Connector as per EN 175301-803 | |
D1FBE01CC0NJE0EE | Backordered | POR | 3-Way | n/a | 3.5 kg | Industrial Systems Division Europe | 40 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 6 L/MIN | E01C | Spool/sleeve | 24 V / 1.15 A | Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity | |
D1FBE01CC0NJW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 6 L/MIN | E01C | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 | |
D1FBE01CC0NKE0EE | Backordered | POR | 3-Way | n/a | 3.5 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Proportional | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 6 L/MIN | E01C | Spool/sleeve | 12 V / 2.3 A | Explosion proof with cable glands, explosion proof solenoids Ex e mb II T4Gb + IECEx conformity | ||
D1FBE01CC0NMW0 | Backordered | POR | 3-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a or b | Overlap | 6 L/MIN | E01C | Spool/sleeve | 9 V / 2.7 A | Connector as per EN 175301-803 | |
D1FBE01CE0NJW0 | Backordered | POR | 2-Way | n/a | 2.2 kg | Industrial Systems Division Europe | 60 °C | -20 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | Solenoid | Hydraulic Oil According to DIN 51524 ... 535 | Proportional DC Valve | 5 bar | External | 20 cSt | <4 % | 60 °C | -25 °C | 60 °C | -20 °C | 400 cSt | IP65 in accordance with EN 60529 | ISO 4406; 18/16/13 | <50 | NG06 / CETOP 03 | Operated in position a | Overlap | 6 L/MIN | E01C | Spool/sleeve | 24 V / 0.8 A | Connector as per EN 175301-803 |
REWARD Status