*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Brand | Division | Maximum Operating Pressure | Mounting Type | Seal Material | Technology | Body Material | Operation Type | Mounting Position | Media | Application | Minimum Fluid Temperature | Maximum Ambient Temperature | Maximum Kinematic Viscosity | Weight | Maximum Flow Rate | Filter Efficiency Rating | For Fluid Type | Minimum Kinematic Viscosity | Minimum Ambient Temperature | Port Connection | Valve Type | Division | Product Series | Maximum Fluid Temperature | Electronics Type | Ingress Protection Rating | Mounting Style | Function | Actuation Type | Power Supply Voltage | Vibration Resistance | Leak Rate | Hysteresis | Response Time | Pressure Differential | Flow Rate | Seal Material | Marking | Port Connection | Connection Type | Flow Rate | Spool Code | Signal Input | Signal Output | Sensor type | Spool Position |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D1FPB31CC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | Proportional | VCD®-actuator | Ripple < 5 V % Eff. | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 6.3 L/min | B31C | ±10 V | ±10 V | omit | Center position | |
D1FPB31CC9NE00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | ISO 4401 | 3-Way | VCD®-actuator | Ripple < 5 V % Eff. | 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 6.3 L/min | B31C | ±20 mA | ±10 V | omit | Center position | |
D1FPB31CC9NN00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | ISO 4401 | Proportional | VCD®-actuator | 24 V Nominal (tolerance range 22 … 30) | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 6.3 L/min | B31C | EtherCAT bus type N | ±10 V | omit | Center position | |
D1FPB31CC9NS00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | Proportional | VCD®-actuator | Ripple < 5 V % Eff. | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 6.3 L/min | B31C | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB31FC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | 3-Way | VCD®-actuator | 24 V Nominal (tolerance range 22 … 30) | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 12/6 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 12.6 L/min | B31F | ±10 V | ±10 V | omit | Center position | |
D1FPB31GC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | NFPA | 3-Way | VCD®-actuator | Ripple < 5 V % Eff. | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 / 8 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 16.8 L/min | B31G | ±10 V | ±10 V | omit | Center position | |
D1FPB31GC9NS00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | NFPA | 3-Way | VCD®-actuator | Surge Free V % Eff. | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 / 8 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 16.8 L/min | B31G | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB31GC9NS50 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | NFPA | 3-Way | VCD®-actuator | Surge Free V % Eff. | 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 / 8 L/min | NBR | Standard | NG06 / CETOP 03 | 11 + PE | 16.8 L/min | B31G | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB31GC9VB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | FPM | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -20 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil | 20 cSt | -20 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | NFPA | 3-Way | VCD®-actuator | Ripple < 5 V % Eff. | 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 / 8 L/min | FPM | Standard | NG06 / CETOP 03 | 6 + PE | 16.8 L/min | B31G | ±10 V | ±10 V | omit | Center position | |
D1FPB31HC9NB70 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | CETOP RP121 | Proportional | VCD®-actuator | 24 V Nominal (tolerance range 22 … 30) | 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 25/12.5 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE + enable | 25/12.5 L/min | B31H | ±10 V | ±10 V | omit | Center position | |
D1FPB31MC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | ISO 4401 | 3-Way | VCD®-actuator | Electric Shut-off at < 19 V Nominal (tolerance range 22 … 30) | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 40/20 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 40/20 L/min | B31M | ±10 V | ±10 V | omit | Center position | |
D1FPB31MC9NB70 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | NFPA | Proportional | VCD®-actuator | Ripple < 5 V % Eff. | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 40/20 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE + enable | 40/20 L/min | B31M | ±10 V | ±10 V | omit | Center position | |
D1FPB31MC9NS00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | 3-Way | VCD®-actuator | Electric Shut-off at < 19 V Nominal (tolerance range 22 … 30) | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 40/20 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 40/20 L/min | B31M | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB32CC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | CETOP RP121 | 3-Way | VCD®-actuator | Electric Shut-off at < 19 V Nominal (tolerance range 22 … 30) | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 6.3 L/min | B32C | ±10 V | ±10 V | omit | Center position | |
D1FPB32CC9NS70 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | ISO 4401 | 3-Way | VCD®-actuator | Surge Free V % Eff. | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 6/3 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE + enable | 6.3 L/min | B32C | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB32FC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | CETOP RP121 | 3-Way | VCD®-actuator | Electric Shut-off at < 19 V Nominal (tolerance range 22 … 30) | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 12/6 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 12.6 L/min | B32F | ±10 V | ±10 V | omit | Center position | |
D1FPB32FC9NB70 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | 3-Way | VCD®-actuator | Ripple < 5 V % Eff. | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 12/6 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE + enable | 12.6 L/min | B32F | ±10 V | ±10 V | omit | Center position | |
D1FPB32FC9NS00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | 3-Way | VCD®-actuator | 24 V Nominal (tolerance range 22 … 30) | 15 Shock Acc. IEC 60068-2-27 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 12/6 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 12.6 L/min | B32F | 4 to 20 mA | ±10 V | omit | Center position | |
D1FPB32GC9NB00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | DIN 24340 | Proportional | VCD®-actuator | Ripple < 5 V % Eff. | 10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 16 L/min | B32G | ±10 V | ±10 V | omit | Center position | |
D1FPB32GC9NS00 | Backordered | POR | PARKER | Industrial Systems Division Europe | 350 bar | Subplate | NBR | Hydraulics | Cast Iron | Direct | Unrestricted | Hydraulic Oil | Industrial Hydraulic | -25 °C | 60 °C | 400 cSt | 3.6 kg | 90 L/min | ISO 4406 18/16/13 | Hydraulic Oil According to DIN 51524 ... 535 | 20 cSt | -25 °C | NG06 / CETOP 03 | Proportional DC Valve | Industrial Systems Division Europe | Proportional DC Valve | 60 °C | Onboard | IP65 in accordance with EN 60529 | CETOP RP121 | Proportional | VCD®-actuator | 24 V Nominal (tolerance range 22 … 30) | 10 Sinus 5...2000 Hz Acc. IEC 60068-2-6 | <50 ml/min | <0.05 % | <3.5 ms | 35 bar | 16 / 8 L/min | NBR | Standard | NG06 / CETOP 03 | 6 + PE | 16.8 L/min | B32G | 4 to 20 mA | ±10 V | omit | Center position |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.