Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialMaximum Operating PressureDivisionMinimum Operating TemperatureMaximum Kinematic ViscosityOverride FunctionalityCoil TypeActuation TypeOperation TypePower ConsumptionInstallation TorqueCoil Nut Tightening TorqueCavity SizeWeightFor Fluid TypeFrequencyConfigurationValve MaterialFilter Efficiency RatingMaximum Inlet Pressure RatingMaximum Operating TemperatureOperating TemperatureResponse TimeMaximum Tank PressureFunctionFlow RateLeak RateSeal MaterialMaximum Flow RateCurrentHysteresisFlow Rate AccuracyVariation of Opening PointOverride FunctionalityConfigurationSeal MaterialMaximum Inlet Pressure RatingFlow Rate
DSP105C1
3 in stock
POR
N/A210 barHydraulic Systems Division-37 °C45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W25 lb-ft3 lb-ftC10-40.57 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+93 °C-37 to +93 °C50 ms3000 psiProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C1M
Backordered
POR
N/A210 barHydraulic Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Push and Pull5/8" Super Coil High Watt (CAP)Electrical, ManualSolenoid operated, Manually operated28 W25 lb-ft3 lb-ftC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+200 °F-37 to +93 °C50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalPush and PullNormally ClosedD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C1MN
124 in stock
POR
N/A3000 psiHydraulic Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Push and Pull5/8" Super Coil High Watt (CAP)Electrical, ManualSolenoid operated, Manually operated28 W34 Nm4.1 NmC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi+250 °F-34 to +121 °C50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalPush and PullNormally ClosedNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C1N
Backordered
POR
N/A210 barHydraulic Systems Division-34 °C45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W25 lb-ft3 lb-ftC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+121 °C-30 to +250 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C1V
Backordered
POR
N/A3000 psiHydraulic Systems Division-26 °C45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W34 Nm3 lb-ftC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+400 °F-15 to +400 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C4
4 in stock
POR
N/A210 barHydraulic Systems Division-35 °F45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W25 lb-ft3 lb-ftC10-40.57 lbMineral-based or synthetic hydraulic fluids100-400 HzFloating CenterAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+200 °F-35 to +200 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/AFloating CenterD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C4M
Backordered
POR
N/A210 barHydraulic Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Push and Pull5/8" Super Coil High Watt (CAP)Electrical, ManualSolenoid operated, Manually operated28 W25 lb-ft4.1 NmC10-40.57 lbMineral-based or synthetic hydraulic fluids100-400 HzFloating CenterAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi+200 °F-37 to +93 °C50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalPush and PullFloating CenterD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C4MN
Backordered
POR
N/A3000 psiHydraulic Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Push and Pull5/8" Super Coil High Watt (CAP)Electrical, ManualSolenoid operated, Manually operated28 W25 lb-ft3 lb-ftC10-40.57 lbMineral-based or synthetic hydraulic fluids100-400 HzFloating CenterAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi+250 °F-34 to +121 °C50 ms3000 psiProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalPush and PullFloating CenterNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C4N
Backordered
POR
N/A3000 psiHydraulic Systems Division-34 °C45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W34 Nm3 lb-ftC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzFloating CenterAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+121 °C-30 to +250 °F50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile32 L/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/AFloating CenterNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
DSP105C4V
Backordered
POR
N/A3000 psiHydraulic Systems Division-15 °F45-2000 SSU (6 to 420 cSt)n/a5/8" Super Coil High Watt (CAP)ElectricalSolenoid Operated28 W34 Nm3 lb-ftC10-40.28 kgMineral-based or synthetic hydraulic fluids100-400 HzFloating CenterAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar+204 °C-15 to +400 °F50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon8.5 Gal/min2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/AFloating CenterFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MIN
GP02511N
Backordered
POR
N/A5000 psiHydraulic Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Non-Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W30 Nm4.1 NmC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+250 °F-30 to +250 °F50 ms210 barProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile15, 17 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNon-DetentedNormally ClosedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN
GP02511V
Backordered
POR
N/A5000 psiHydraulic Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Non-Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.15 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+204 °C-26 to +204 °C50 ms3000 psiProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNon-DetentedNormally ClosedFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN
GP02512N
Backordered
POR
N/A5000 psiHydraulic Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W30 Nm4.1 NmC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 45000 psi+121 °C-34 to +121 °C50 ms210 barProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalDetentedNormally ClosedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN
GP02512V
Backordered
POR
N/A5000 psiHydraulic Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W22 lb-ft4.1 NmC08-40.15 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+204 °C-26 to +204 °C50 ms210 barProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalDetentedNormally ClosedFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN
GP0251L1N
Backordered
POR
N/A350 barHydraulic Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Non-Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W30 Nm3 lb-ftC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 45000 psi+121 °C-30 to +250 °F50 ms3000 psiProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNon-DetentedNormally ClosedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN
GP0251L2N
Backordered
POR
N/A350 barHydraulic Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Detented1/2" Super CoilElectrical, ManualSolenoid operated, Manually operated14, 19 W22 lb-ft3 lb-ftC08-40.15 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+250 °F-30 to +250 °F50 ms210 barProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalDetentedNormally ClosedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN
GP0251LN
Backordered
POR
N/A5000 psiHydraulic Systems Division-30 °F45-2000 SSU (6 to 420 cSt)n/a1/2" Super CoilElectricalSolenoid Operated14, 19 W22 lb-ft4.1 NmC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+121 °C-30 to +250 °F50 ms3000 psiProportional Directional Control0.9, 1.4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile0.9, 1.4 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedNitrile5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN
GP0251LV
Backordered
POR
N/A350 barHydraulic Systems Division-26 °C45-2000 SSU (6 to 420 cSt)n/a1/2" Super CoilElectricalSolenoid Operated14, 19 W22 lb-ft3 lb-ftC08-40.15 kgMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 45000 psi+400 °F-15 to +400 °F50 ms3000 psiProportional Directional Control3.4, 5.3 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon3.4, 5.3 L/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedFluorocarbon5000 PSI, 350 BAR0.9, 1.4 GAL/MIN, 3.4, 5.3 L/MIN
GP0251N
Backordered
POR
N/A350 barHydraulic Systems Division-30 °F45-2000 SSU (6 to 420 cSt)n/a1/2" Super CoilElectricalSolenoid Operated14, 19 W22 lb-ft4.1 NmC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+250 °F-30 to +250 °F50 ms210 barProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedNitrile5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN
GP0251V
Backordered
POR
N/A350 barHydraulic Systems Division-26 °C45-2000 SSU (6 to 420 cSt)n/a1/2" Super CoilElectricalSolenoid Operated14, 19 W22 lb-ft3 lb-ftC08-40.34 lbMineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar+400 °F-26 to +204 °C50 ms3000 psiProportional Directional Control15, 17 L/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/min1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalN/ANormally ClosedFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MIN

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains