*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Function | Actuation Type | Minimum Operating Temperature | Division | Maximum Operating Temperature | Maximum Operating Pressure | Mounting Type | Seal Material | For Fluid Type | Body Material | Operation Type | Mounting Position | Weight | Maximum Flow Rate | Product Series | Seal Material | Marking | Port Connection | Spool Code | Spool Position | Signal Input | Solenoid Connection | Solenoid Option | Nominal Size | Corrosion Resistance Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D1MW030BNJA | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | 2-pin AMP Junior Timer | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW030BNJAW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | 2-pin AMP Junior Timer | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW030BNJJ | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | DT04-2P | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW030BNJJ1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | DT04-2P | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW030BNJJW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | DT04-2P | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW030BNJW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | EN 175301-803 | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW030BNJWW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW030BVJW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Water-Glycol | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | FPM | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position b, operated in position a | 24 V | EN 175301-803 | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW030DNJWW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, operated in position a or b, no center, no offset position | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW030HNJJ | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position a, operated in position b | 24 V | DT04-2P | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW030HNJW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position a, operated in position b | 24 V | EN 175301-803 | Standard solenoid | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW030HNJWW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 030 | 2 positions, spring offset in position a, operated in position b | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW034CNJJ | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 2.1 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 034 | 3 positions, spring offset in position 0, operated in position a or b | 24 V | DT04-2P | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW083BNJJ | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 083 | 2 positions, spring offset in position a, operated in position b | 24 V | DT04-2P | Standard solenoid | NG06 / CETOP 03 | Standard surface protection | |
D1MW083BNJJW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 083 | 2 positions, spring offset in position a, operated in position b | 24 V | DT04-2P | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating | |
D1MW083HVJWW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Water-Glycol | Cast Iron | Direct | Unrestricted | 1.5 kg | 80 L/min | Directional Control Valve | FPM | Standard | NG06 / CETOP 03 | 083 | 2 positions, spring offset in position b, operated in position a | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW208BNJWW | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 208 | 2 positions, spring offset in position b, operated in position a | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Standard surface protection | |
D1MW208HNJWW1P | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Hydraulic Oil According to DIN 51524 | Cast Iron | Direct | Preferably Horizontal | 1.5 kg | 80 L/min | Directional Control Valve | NBR | Standard | NG06 / CETOP 03 | 208 | 2 positions, spring offset in position a, operated in position b | 24 V | EN 175301-803 | Extended manual override with rubber cover | NG06 / CETOP 03 | Anti corrosion coating |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.
Click quantity In Stock to view warehouse location detail.