• Availability & Price
  • Search SKU
Filter by attributes
  • Brand
  • Compatible After Filter
  • Compatible After Filter Element
  • Compatible Prefilter
  • Compatible Prefilter Element
  • Connection Type
  • Depth
  • Division
  • Electrical Requirements
  • Height
More Filters...

Externally Heated Desiccant Air Dryer - TWP Series

Picture for category Externally Heated Desiccant Air Dryer - TWP Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate.  These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems.

A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.

Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.

Features/Benefits
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7” HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all
operational information

*Optional equipment
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceWeightMinimum Operating TemperatureConnection TypeCompatible After FilterCompatible PrefilterMaximum Flow RateDivisionWidthHeightMaximum Operating PressureCompatible Prefilter ElementCompatible After Filter ElementMaximum Operating TemperatureMaximum Ambient TemperatureBrandInstalled Condensate Drain TypeMaximum Inlet Pressure RatingMinimum Operating PressureOptional AccessoriesDepthMinimum Ambient TemperatureProduct TypePurge Pressure RateMaximum Flow Rate (cfm)Pressure Dew Point (F)Electrical Requirements
TWP1001FY41NNN
Backordered
POR
4195 lb50 °F3" FlgJC1000-FHJC1000-C1699 m3/hourIndustrial Gas Filtration and Generation Division74 inch102 inch150 psiJE-CC0800JE-FC0800-HT120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration41 inch40 °FHeated701000-40460V/3Ph/60Hz
TWP1201FY41NNN
Backordered
POR
5215 lb50 °F3" FlgJLA1800-FHJLA1603-C2038 m3/hourIndustrial Gas Filtration and Generation Division74 inch113 inch150 psi(2) JAE3-CJAE4-FH120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration41 inch40 °FHeated841200-40460V/3Ph/60Hz
TWP1501FY41NNN
Backordered
POR
7765 lb50 °F3" FlgJLA1800-FHJLA1603-C2548 m3/hourIndustrial Gas Filtration and Generation Division78 inch113 inch150 psi(2) JAE3-CJAE4-FH120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration60 inch40 °FCompressed Air – Desiccant1051500-40460V/3Ph/60Hz
TWP2001FY41NNN
Backordered
POR
8565 lb50 °F4" FlgJLA2600-FHJLA2100-C3398 m3/hourIndustrial Gas Filtration and Generation Division78 inch110 inch135 psi(3) JAE3-C(2) JAE4-FH120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration60 inch40 °FCompressed Air – Desiccant1402000-40460V/3Ph/60Hz
TWP201BY21NNN
Backordered
POR
920 lb50 °F1 1/2” NPTJC0250-FHJC0250-C340 m3/hourIndustrial Gas Filtration and Generation Division40 inch85 inch150 psiJE-CC0350JE-FC0350-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration22 inch40 °FCompressed Air – Desiccant14200-40240V/1Ph/60Hz
TWP251BY21NNN
Backordered
POR
1180 lb50 °F1 1/2" NPTJC0250-FHJC0250-C425 m3/hourIndustrial Gas Filtration and Generation Division40 inch85 inch150 psiJE-CC0350JE-FC0350-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration22 inch40 °FHeated17.5250-40240V/1Ph/60Hz
TWP2601FY41NNN
Backordered
POR
11562 lb50 °F4" FlgJLA2600-FHJLA3200-C4417 m3/hourIndustrial Gas Filtration and Generation Division96 inch112 inch135 psi(4) JAE3-C(2) JAE4-FH120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration60 inch40 °FHeated1822600-40460V/3Ph/60Hz
TWP3001FY41NNN
Backordered
POR
12002 lb50 °F6" FlgJLA3506-FHJLA3206-C5097 m3/hourIndustrial Gas Filtration and Generation Division96 inch112 inch135 psi(4) JAE3-C(3) JAE3-FH120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After Filtration60 inch40 °FHeated2103000-40460V/3Ph/60Hz
TWP301BY41NNN
Backordered
POR
1370 lb50 °F1 1/2" NPTJC0350-FHJC0350-C510 m3/hourIndustrial Gas Filtration and Generation Division43 inch87 inch150 psiJE-CC0350JE-FC0350-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration27 inch40 °FHeated21300-40460V/3Ph/60Hz
TWP4001FY41NNN
Backordered
POR
n/a Contact us50 °F6" FlgConsult FactoryConsult Factory6796 m3/hourIndustrial Gas Filtration and Generation DivisionConsult Factory inchConsult Factory inch135 psiConsult FactoryConsult Factory120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After FiltrationConsult Factory40 °FCompressed Air – Desiccant2804000-40460V/3Ph/60Hz
TWP401BY41NNN
Backordered
POR
1400 lb50 °F2" NPTJC0450-FHJC0450-C680 m3/hourIndustrial Gas Filtration and Generation Division47 inch88 inch150 psiJE-CC0450JE-FC0450-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration27 inch40 °FCompressed Air – Desiccant28400-40460V/3Ph/60Hz
TWP5001FY41NNN
Backordered
POR
n/a Contact us50 °F6" FlgConsult FactoryConsult Factory8495 m3/hourIndustrial Gas Filtration and Generation DivisionConsult Factory inchConsult Factory inch135 psiConsult FactoryConsult Factory120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After FiltrationConsult Factory40 °FCompressed Air – Desiccant3505000-40460V/3Ph/60Hz
TWP501BY41NNN
Backordered
POR
2060 lb50 °F2" NPTJC0625-FHJC0625-C850 m3/hourIndustrial Gas Filtration and Generation Division50 inch89 inch150 psiJE-CC0625JE-FC0625-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration27 inch40 °FCompressed Air – Desiccant35500-40460V/3Ph/60Hz
TWP6001FY41NNN
Backordered
POR
n/a Contact us50 °F6" FlgConsult FactoryConsult Factory10194 m3/hourIndustrial Gas Filtration and Generation DivisionConsult Factory inchConsult Factory inch135 psiConsult FactoryConsult Factory120 °F120 °FAirtekDemand Solenoid Drain100 psi80 psiPre and After FiltrationConsult Factory40 °FHeated4206000-40460V/3Ph/60Hz
TWP601BY41NNN
Backordered
POR
2350 lb50 °F2" NPTJC0625-FHJC0625-C1019 m3/hourIndustrial Gas Filtration and Generation Division52 inch92 inch150 psiJE-CC0625JE-FC0625-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration28 inch40 °FCompressed Air – Desiccant42600-40460V/3Ph/60Hz
TWP801BY41NNN
Backordered
POR
3035 lb50 °F2" NPTJC0800-FHJC0800-C1359 m3/hourIndustrial Gas Filtration and Generation Division63 inch93 inch150 psiJE-CC0800JE-FC0800-HT120 °F120 °FAirtekTimed Solenoid Drain100 psi80 psiPre and After Filtration35 inch40 °FCompressed Air – Desiccant56800-40460V/3Ph/60Hz

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains