• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Body Material
  • Bypass Option Included
  • Division
  • For Fluid Type
  • Height
  • Length
  • Materials of Construction
  • Maximum Displacement
  • Maximum Flow Rate
More Filters...

Gerotor Pump – QPM3 series - (Europe)

Picture for category Gerotor Pump – QPM3 series - (Europe)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s QPM3 compact, lightweight range of gerotor circulation pump offers high performance, low noise levels and low energy consumption.

The special design of the pressure relief groove ensures low flow pulsations and low noise levels. Double-feed gerotor provides excellent suction ability and dual shaft bearings ensure a long service life. The design of the pressure chambers offers low pressure pulsations and the QPM3 design and material selection make the pump light and compact.

The low pressure QPM3 has a dual shaft bearing and a resilient connection that guarantees safe and secure operation. It conforms to EN 60034-1/IEC 60072 version B34, which allows the use of different makes of electric motors.

Markets:
• Industrial

Features/Benefits:
• Light and compact
• Suitable for many applications
• Cost-efficient and environmentally friendly
• Low noise levels
• Low energy consumption
• High performance
• Maximum suction height 1m.

Applications:
• Circulation of oil in cooling and oil filter systems
• Circulation of oil in industrial hydraulic systems
• Filling and draining of oil in tanks
• Transfer of oil in stationary or mobile oil storage depots.

Function:
The gerotor principle is based on an inner and an outer rotor. The inner rotor has one less tooth than the outer. The inner rotor has its centre-line positioned at a fixed eccentricity from the centre-line of the outer rotor. As the rotors rotate about their own respective axes, oil is drawn into the enlarging chamber. The process occurs constantly for each chamber, providing a smooth pumping action.

A small selection of part numbers have been included however for more options and information please download the QPM3 brochure or contact your local Parker sales office.  

Formerly branded as Oiltech and Olaer
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionMaterials of ConstructionMaximum Operating PressureWeightMaximum Fluid TemperatureBypass Option IncludedWidthHeightLengthProduct TypeFor Fluid TypeMaximum Flow RatePort SizeMotor TypeApplicationNoise LevelMotor Power Output RatingSizeMediaPump TypeBody MaterialMaximum DisplacementMaximum Vacuum Flow RateRated Flow (lpm)
58631001
Backordered
POR
Cylinder and Accumulator Division - EuropeSteel10 bar13 kg100 °CNo Bypass157 mm195 mm368 mmQPM3 10-8-0,25 230/400-50Mineral Oils10 L/minG 1230/400V, 50HzPower Units650.2510Mineral OilsGerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a10/12 (50/60 Hz)
58632001
Backordered
POR
Cylinder and Accumulator Division - EuropeSteel10 bar13 kg100 °CNo Bypass157 mm195 mm368 mmQPM3 20-4-0,75 230/400-50Mineral Oils Max. 800 cSt20 L/minG 1 inch Outlet460-480V, 60HzLubrication Systems650.7520Vegetable Oils Consult Parker for other fluids.GerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a20/24 (50/60 Hz)
58634001
Backordered
POR
Cylinder and Accumulator Division - EuropeSteel10 bar13 kg100 °CNo Bypass157 mm195 mm381 mmQPM3 40-4-0,75 230/400-50Mineral Oils40 L/minG 13-PhaseLubrication Systems650.7540Synthetic OilsGerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a40/48 (50/60 Hz)
58634050
Backordered
POR
Cylinder and Accumulator Division - EuropeShaft/Gerotor to Steel10 bar21 kg100 °CNo Bypass185 mm230 mm480 mmQPM3 40-4-1.5 230/400-50Mineral Oils40 L/minG 1-1/2AC 230/400V 50HzPower Units66 dBA1.5 kW40Vegetable OilsGerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a40/48 (50/60 Hz)
58636001
Backordered
POR
Cylinder and Accumulator Division - EuropeSteel10 bar14 kg100 °CNo Bypass157 mm195 mm393 mmQPM3 60-4-0,75 230/400-50Mineral Oils Max. 800 cSt60 L/minG 1 inch Outlet3-PhaseGeneral Industrial650.7560Vegetable Oils Consult Parker for other fluids.GerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a60/72 (50/60 Hz)
58638001
Backordered
POR
Cylinder and Accumulator Division - EuropeSteel10 bar22 kg100 °CNo Bypass185 mm220 mm481 mmQPM3 80-4-1,5 230/400-50Mineral Oils Max. 800 cSt80 L/minG 1 inch Outlet460-480V, 60HzLubrication Systems671,580Synthetic Oils Consult Parker for other fluids.GerotorPump Housing/Pump Cover to Aluminum with Anodized surfacesn/an/a80/96 (50/60 Hz)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains