• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Brand
  • Compatible Element
  • Connection Type
  • Division
  • Division
  • Drain
  • Element Change Interval
  • Filter Efficiency Rating
  • Filter Type
More Filters...

GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

Picture for category GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker GH series high pressure filters are designed to be ideal for high pressure applications up to 100 bar g. The innovative construction features of the filter housing provide a reliable assembly, as well as simple and safe handling for replacing the filter element. One essential construction feature is the double O-ring seal which protects the housing thread against pollution and humidity and therefore prevents the thread from corrosion. Additionally the second O-ring prevents the filter housing parts from over winding.

By fastening the filter element via its base thread screwed on the tie-rod, this provides the greatest operating safety, even under the pressure pulsations in intermittent operation that are common for high pressure applications.

Highly effective pleated media in four different grades provide an element surface that is four times the size, compared to the conventional wrapped design. The result is a reduced flow speed and efficient separation simultaneously with low pressure drop, thus providing cost reduction during operation with reliable separation performance.

Features
• Optimised flow rates and compact filter housing.

• Improved housing design with double O-ring sealing.

• Threaded rod element fixing.

• Pleated elements.

• Complete filter including filter element and manual drain.

• As an option filters are also available without a drain.

• All filter sizes offer connectors for the installation of calibrated differential pressure gauges.

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyDivisionIndustryApplicationDivisionElement Change IntervalWeightWidthProduct TypeFilter Efficiency RatingHeightProduct SeriesOperating PressureSpecifications MetResidual Oil ContentPressure DifferentialMaterials of ConstructionMicron RatingDrainFilter TypeConnection TypeFlow RateCompatible ElementOperating TemperatureOperating Temperature
GH7/100A
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAWhen Oil Vapour is detected3.4 kg3.1 inchCompressed Air Filtern/a420.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Saturated: n/aHousing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)1140A2 to 50°C (35 to 122°F)
GH7/100V
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours7 lb80.0 mmCompressed Air Filter> 90 %16.5 inchGH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)1140V2 to 80°C (35 to 176°F)
GH7/100XP
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours3.4 kg3.1 inchCompressed Air Filter> 99.9999 %420.0 mmGH100100.0 barg MaximumPED Fluid Group II, TR0.1 mg/m³ - 0.01 ppm(wSaturated: < 400 mbar (< 5.8 psi)Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRDown to 0.01 μmManualOil Removal Filter½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)1140XP2 to 80°C (35 to 176°F)
GH7/100ZP
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours7 lb80.0 mmCompressed Air Filter> 99.925 %16.5 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRDown to 1 μmManualCoalescing & Dry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)1140ZP2 to 80°C (35 to 176°F)
GH9/100A
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEAWhen Oil Vapour is detected40 lb4.6 inchCompressed Air Filtern/a455.0 mmGH1001450.0 psig MaximumPED Fluid Group II, TR0.003 mg/m³ - 0.003 ppm(w)Dry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRn/aManualOil Vapour Reduction¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)2010A2 to 50°C (35 to 122°F)35 to 122 °F
GH9/100V
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours18.2 kg4.6 inchCompressed Air Filter> 90 %17.9 inchGH100100.0 barg MaximumPED Fluid Group II, TRN/ADry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 3μmManualDry Particulate¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)2010V2 to 80°C (35 to 176°F)35 to 176 °F
GH9/100XP
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours18.2 kg116.0 mmCompressed Air Filter> 99.9999 %17.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.1 mg/m³ - 0.01 ppm(wDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 0.01 μmManualOil Removal Filter¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)2010XP2 to 80°C (35 to 176°F)35 to 176 °F
GH9/100ZP
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA12 months or 6000 hours18.2 kg116.0 mmCompressed Air Filter> 99.925 %17.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TR0.5 mg/m³ - 0.5 ppm(w)Saturated: < 370 mbar (< 5.4 psi)Housing<br/>Steel<br/><br/>Seal<br/>NBRDown to 1 μmManualCoalescing & Dry Particulate¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)2010ZP2 to 80°C (35 to 176°F)35 to 176 °F

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains