Global Soft Start / Dump Valve - P32T Series (Compact) - Pneumatic Division Europe

Picture for category Global Soft Start / Dump Valve - P32T Series (Compact) - Pneumatic Division Europe

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

P32T soft start / dump valves series are an important safety factor and prevent damage to systems when air pressure is introduced at machine or system start up as pilot operated device. P32T modular global compact combined soft start / dump valves provide for the safe introduction of pressure to machines or systems.  Soft start / dump valves, when set, allow the pressure to gradually build to the set point before fully opening to deliver full flow air line pressure. The controlled introduction can be an important safety factor and prevent damage to tooling when air pressure is introduced at machine or system start up. When the valve is installed into the pneumatic system and the pilot operator receives no signal, the air is blocked at port 1. When a pilot signal is received at the pilot operator, the valve shifts, closing the connection between ports 2 and 3. At the same time, air flow begins between ports 1 and 2 at a slow rate, controlled by the needle valve located on top of the valve. When the downstream pressure reaches approximately 60% of the supply pressure, the main valve spool opens, allowing full flow through the valve in the system. If pilot signal or system pressure is lost, the valve returns to its initial state, venting the downstream pressure through port 3.

Pressure supply piping must be the same size as the inlet port or larger, to insure the pilot valve receives sufficient pressure supply during high flow conditions. The valve should be mounted downstream of the FRL, with the soft start adjustment needle easily accessible. Note: soft start/dump valves are not intended to be used as emergency shut-off valves, but should be placed after a manual shut off valve. The P32T can be mounted using a modular connector to other P32 global air preparation products.   

Markets
• Air and Gas
• Appliances
• Entertainment Automation
• Factory Automation
• Machine Tools
• Misc. Industrial
• Misc. Manufacturing
• Molding
• Packaging Machinery
• Printing and Marking Equipment
• Vehicle Assembly Facilities
• Wearing Apparel
• Food and Beverage
• Misc. Processing

Features/Benefits
• Modular design with 1/2" integral ports (NPT, BSPP & BSPT)
• Provides for the safe introduction of pressure
• The 3-way, 2-position function automatically dumps downstream pressure on the loss of pilot signal
• Adjustable slow start
• Solenoid or air pilot options
• High flow & exhaust capability
• Silencer included

Applications
To be used in combination with valves and cylinders main function to protect and as safety device in
• Positioning
• Cutting
• Machining
• Pick and place
• Packaging and wrapping systems

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPricePort SizeDivisionWeightElectrical ConnectionPort TypeNumber of PositionsInput VoltageMinimum Operating PressureProduct TypeFunctionSpecifications MetActuation TypeMaximum Flow RateMaximum Ambient TemperatureMaximum Inlet Pressure RatingSolenoid Option
P32TA14PPN
Backordered
POR
1/2 inchElectric Motion and Pneumatic Division - Europe2 lbn/aBSPP2n/a3 barSoft Start / Dump Valve3/2ATEX 'Out of Scope' Certification - no solenoid coil option only (Group II Cat2 zone 1,21) | CEI/ICE 61373 1999-1 Cat2 (BS EN 61373:1999)External Air Pilot101 @ 91 psig SCFM-4° to 176° °F17 barExternal Air Pilot Operated
P32TA14SCN0000
Backordered
POR
1/2 inchElectric Motion and Pneumatic Division - Europe0.87 kgn/aBSPP2n/a3 barSoft Start / Dump Valve3/2ATEX 'Out of Scope' Certification - no solenoid coil option only (Group II Cat2 zone 1,21) | CEI/ICE 61373 1999-1 Cat2 (BS EN 61373:1999)Solenoid101 @ 91 psig SCFM-10° to 50° °C10 barSolenoid Operated (solenoid not included)
P32TA14SCNA2CN
Backordered
POR
1/2 inchElectric Motion and Pneumatic Division - Europe0.9 kg30mm 3-Pin ( ISO 4400 Form A) or 2-Pin M12BSPP224VDC3 barSoft Start / Dump Valve3/2ATEX 'Out of Scope' Certification - no solenoid coil option only (Group II Cat2 zone 1,21) | CEI/ICE 61373 1999-1 Cat2 (BS EN 61373:1999)Solenoid48 @ 6.3 bar dm3/sec-10° to 50° °C10 barSolenoid Operated / 24VDC / 22mm Coil

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains