• Availability & Price
  • Search SKU
Filter by attributes
  • Brand
  • Compatible After Filter
  • Compatible After Filter Element
  • Compatible Prefilter
  • Compatible Prefilter Element
  • Connection Type
  • Depth
  • Division
  • Electrical Requirements
  • Height
More Filters...

Heatless Desiccant Air Dryer - TW Series

Picture for category Heatless Desiccant Air Dryer - TW Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Airtek TW Series Heatless Desiccant Air Dryers remove water vapor from compressed air through a process known as Pressure Swing Adsorption. A standard pressure dewpoint of -40°F (-40°C) is attained by directing the flow of saturated compressed air over a bed of desiccant.

The most commonly used desiccant is activated alumina, a spherical shaped, hygroscopic material, selected for its consistent size, shape and extreme surface to mass ratio. This physically tough and chemically inert material is contained in two separate but identical pressure vessels commonly referred to as “dual” or “twin” towers.

As the saturated compressed air flows up through the “on line” tower, its moisture content adheres to the surface of the desiccant. The dry compressed air is then discharged from the chamber into the distribution system.

A solid state controller automatically cycles the flow of compressed air between the towers, while the “on line” tower is drying, the “off line” tower is regenerating. Regeneration, sometimes referred to as purging, is the process by which moisture accumulated during the “on line” cycle is stripped away during the “off line” cycle. As dry low pressure purge air flows gently through the regenerating bed, it attracts the moisture that had accumulated on the surface of the desiccant during the drying cycle and exhausts it to the atmosphere.

To protect the desiccant bed from excess liquid, all Parker Airtek TW Series Heatless Air Dryers are designed to work with the natural pull of gravity. By directing the saturated air into the bottom of the “on line” tower and flowing up through the bed, liquid condensate caused by system upset, is kept away from the desiccant and remains at the bottom of the tower where it can be easily exhausted during the regeneration cycle. Counter flow purging ensures optimum performance by keeping the driest desiccant at the discharge end of the dryer.

Heatless dryers in general are the most reliable and least expensive of all desiccant type dryers. Parker Airtek TW Series Heatless Desiccant Air Dryers are the most energy efficient thanks to standard features like, “Variable Cycle control”, “CycleLoc™” and purge flow regulator.
Features/Benefits
Basic Controller
• Allen Bradley® PLC
• Nema 4X enclosure
• LCD user interface
• Four line digital display features:
o Tower drying indication
o Tower regenerating indication
o Run status
o Time remaining in cycle
• Selectable cycle settings
• Programmable drain timer (drain on, time and test)
• Compressor demand via external dry contact
(CycleLoc®)
• Power ON/OFF switch
• Step-through regeneration for maintenance

Advanced Controller
• Allen Bradley® PLC
• Powerloc™ Energy Demand System
• Nema 4X enclosure
• 3.5” LCD user interface
• Dew point sensor input (-148 to 68°F)
• Optional 4-20 mA output for remotely monitoring dew point
• Tower pressure sensors
• Inlet pressure and temperature sensors
• Compressor demand via external dry contact (CycleLoc®)
• Modbus/TCP communications via standard ethernet port
• Modbus RTU communications via optional RS232/485 port (Using external gateway device)
• SD card slot for accessing historical data and alarm information
• Selectable cycle settings
• Programmable drain timer (drain on, time and test)
• User selectable alarms with common alarm relay
o High inlet temperature
o Low inlet pressure
o Tower failed to blow down (switch failure)
o Tower failed to pressurize
o High dew point
o Sensor failure for all sensors
• Filter maintenance & alarm
• Clogged muffler maintenance and alarm
• Power ON/OFF switch
• Alarm log stores most recent alarms
• Flashes green when in energy savings mode
• Flashes red when an alarm is present
• Dry contact for common alarm
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMinimum Operating TemperatureMaximum Operating PressureOptional AccessoriesMaximum Ambient TemperaturePurge Pressure RateCompatible Prefilter ElementWidthDivisionDepthHeightMaximum Operating TemperatureMaximum Flow RateBrandWeightMaximum Inlet Pressure RatingMinimum Operating PressureCompatible After FilterInstalled Condensate Drain TypeCompatible PrefilterMinimum Ambient TemperatureConnection TypeCompatible After Filter ElementPressure Dew Point (F)Maximum Flow Rate (cfm)Electrical Requirements
TW101BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F16JE-CC011031 inchIndustrial Gas Filtration and Generation Division18 inch79 inch120 °F181.79 m3/hourAirtek468 lb100 psi80 psiJC0110-FTimed DrainJC0110-C40 °F1 NPTJE-FC0110-40107120 v / 1 ph / 60 hz
TW1201FY14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F180JAE3-C Qty 274 inchIndustrial Gas Filtration and Generation Division41 inch103 inch120 °F2038.81 m3/hourAirtek4605 lb100 psi80 psiJLA1800-FTimed DrainJLA1603-C40 °F3 FLGJAE4-F-401200120 v / 1 ph / 60 hz
TW131BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F20JE-CC015031 inchIndustrial Gas Filtration and Generation Division18 inch79 inch120 °F229.37 m3/hourAirtek496 lb100 psi80 psiJC0150-FTimed DrainJC0150-C40 °F1 NPTJE-FC0150-40135120 v / 1 ph / 60 hz
TW1501FY14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F225JAE3-C Qty 274 inchIndustrial Gas Filtration and Generation Division41 inch113 inch120 °F2548.52 m3/hourAirtek4985 lb100 psi80 psiJLA1800-FTimed DrainJLA1603-C40 °F3 FLGJAE4-F-401500120 v / 1 ph / 60 hz
TW2001FY14NNN
Backordered
POR
50 °F135 psiPre and After Filter120 °F300JAE3-C Qty 278 inchIndustrial Gas Filtration and Generation Division48 inch96 inch120 °F3398.02 m3/hourAirtek5206 lb100 psi80 psiJLA1800-FTimed DrainJLA1603-C40 °F4 FLGJAE4-F-402000120 v / 1 ph / 60 hz
TW201BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F30JE-CC035037 inchIndustrial Gas Filtration and Generation Division22 inch82 inch120 °F339.8 m3/hourAirtek692 lb100 psi80 psiJC0250-FTimed DrainJC0250-C40 °F1 1/2 NPTFC-0600-40200120 v / 1 ph / 60 hz
TW251BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F38JE-CC035040 inchIndustrial Gas Filtration and Generation Division22 inch80 inch120 °F424.75 m3/hourAirtek776 lb100 psi80 psiJC0250-FTimed DrainJC0250-C40 °F1 1/2 NPTFC-0600-40250120 v / 1 ph / 60 hz
TW2601FY14NNN
Backordered
POR
50 °F135 psiPre and After Filter120 °F390JAE3-C Qty 496 inchIndustrial Gas Filtration and Generation Division60 inch112 inch120 °F4417.43 m3/hourAirtek7600 lb100 psi80 psiJLA2600-FTimed DrainJLA3200-C40 °F4 FLGJAE3-F Qty 2-402600120 v / 1 ph / 60 hz
TW3001FY14NNN
Backordered
POR
50 °F135 psiPre and After Filter120 °F450JAE3-C Qty 496 inchIndustrial Gas Filtration and Generation Division60 inch112 inch120 °F5097.03 m3/hourAirtek8300 lb100 psi80 psiJLA3506-FTimed DrainJLA3206-C40 °F6 FLGJAE3-F Qty 3-403000120 v / 1 ph / 60 hz
TW301BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F45JE-CC035040 inchIndustrial Gas Filtration and Generation Division22 inch80 inch120 °F509.7 m3/hourAirtek796 lb100 psi80 psiJC0350-FTimed DrainJC0350-C40 °F1 1/2 NPTFC-0600-40300120 v / 1 ph / 60 hz
TW401BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F60JE-CC045043 inchIndustrial Gas Filtration and Generation Division27 inch85 inch120 °F679.6 m3/hourAirtek1626 lb100 psi80 psiJC0450-FTimed DrainJC0450-C40 °F2 NPTFC-0750-40400120 v / 1 ph / 60 hz
TW41BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F6JE-CC005021 inchIndustrial Gas Filtration and Generation Division14 inch48 inch120 °F71.36 m3/hourAirtek190 lb100 psi80 psiJC0050-FTimed DrainJC0050-C40 °F1/2 NPTJE-FC0050-4042120 v / 1 ph / 60 hz
TW501BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F77JE-CC062545 inchIndustrial Gas Filtration and Generation Division27 inch84 inch120 °F866.5 m3/hourAirtek1735 lb100 psi80 psiJC00625-FTimed DrainJC00625-C40 °F2 NPTFC-1035-40510120 v / 1 ph / 60 hz
TW56BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F9JE-CC011021 inchIndustrial Gas Filtration and Generation Division14 inch65 inch120 °F101.94 m3/hourAirtek230 lb100 psi80 psiJC0085-FTimed DrainJC0085-C40 °F3/4 NPTJE-FC0110-4060120 v / 1 ph / 60 hz
TW76BN14NNN
Backordered
POR
50 °F150 psiPre and After Filter120 °F11JE-CC011030 inchIndustrial Gas Filtration and Generation Division18 inch81 inch120 °F127.43 m3/hourAirtek384 lb100 psi80 psiJC0085-FTimed DrainJC0085-C40 °F3/4 NPTJE-FC0110-4075120 v / 1 ph / 60 hz

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains