• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Brand
  • Connection Tube Outside Diameter
  • Connection Type
  • Connection Type
  • Division
  • Division
  • Flange Size
  • Flange Size
  • Industry
More Filters...

HPF - High Performance Non-Weld Flange System

Picture for category HPF - High Performance Non-Weld Flange System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

HPF is generally applicable for working pressures up to 420 bar. But the design opens the door to go even beyond this pressure rating: by choosing a suitable combination of flange, insert and tube the pressure rating can be increased to 500 bar.
The System is adjusted to standard tube dimensions with diameters from 25 to 150 mm and wall thickness up to 20 mm. It is designed for flange patterns according to ISO 6162-1 (SAE J518, code 61), ISO 6162-2 (SAE J518, code 62) and ISO 6164.

Markets:
• Environment
• Industrial
• Machine Tools
• Marine
• Materials Handling
• Mobile
• Power Generation
• Press Building

Applications:
• Suitable for general hydraulic and industrial applications.

Features/ Benefits of Parker High Performance Flanges:
• The Parker High Performance Flange System stands for total cost reductions! Compared to conventional welding, the High Performance Flange System leads to several time and cost benefits: The pipework fabrication is very fast and the installation time shorter compared to welding. X-ray is not necessary and there are no post-welding cleaning costs. The flushing costs are reduced as well.
• The Parker High Performance Flange System is worldwide available through the Parker distribution network.
• In addition to the product range, Parker offers value added service, because Parker is able to engineer your hydraulic application.


The system
HPF is generally applicable for working pressures up to 420 bar. But the design opens the door to go even beyond this pressure rating: by choosing a suitable combination of flange, insert and tube the pressure rating can be increased to 500 bar. The System is adjusted to standard tube dimensions with diameters from 25 to 150 mm and wall thickness up to 20 mm. It is designed for flange patterns according to ISO 6162-1 (SAE J518, code 61), ISO 6162-2 (SAE J518, code 62) and ISO 6164.

Learning from nature
The best solutions for complex design problems can often be found in nature. The flaring of a tube is similar to the shape of a branch where it joints the trunk of a tree: The tube is flared by hydraulic axial pressure giving it a parabolic shaping, increasing from 10° up to 37°. The initial gentle incline of the shaping guarantees additional safety against strong system vibrations. The DGUV confirmed the capability of this unique, patented system especially for the use in hydraulic and mechanical presses as well as in hydraulic power systems for injection moulding machines. Beside that, the system is an ideal solution for marine and offshore applications. It is type approved by various classification societies like DNV/GL, LR and others.

The HPF Connector - Strong teamwork for the toughest demands
HPF flanges are equipped with a specially designed and hardened inner grip contour, providing excellent additional tear-off safety for the connection. Optionally some sizes are equipped with special lockrings. A soft sealed, shaped insert is placed into the flared end of the tube. The tube side of the insert is equipped with an O-Ring. On the port side the sealing is guaranteed by an O-Ring or by the special profile F37 Seal. The F37 Seal was developed especially for the use with SAE flanges. These special seals guarantee a high form stability. Compared to standard O-Rings, their mechanical properties prevent gap extrusion, even when the flanges “breathe” under pressure. The special profile of the F37 Seal is ideally adapted to higher pressures or unsuitable surface finish of the flanges. The application of these soft-sealing elements both on the port side and tube side guarantees the gas leak tightness of the HPF connector. As the insert does not have a toothed profile, it can be easily assembled repeatedly.

Tube forming
The tube forming is performed by the Parflange® HPF machines; they can either be purchased or rented for a certain period of time. If required, assembly of ready-to-install straight or manipulated HPF tube lines can be carried out by a Parker CPS Piping Center.

Flanging instead of welding: Error-free and riskless assembly
Nowadays many tube connections are welded. However, as even the best welding operator may make a mistake, each welding seam has to be tested, leading to an enormous loss of time and a significant increase of costs. Even finding trained staffed may be critical. Apart from enormous time savings for the joint preparation itself, HPF offers various advantages compared to the welding solution:
• Welding galvanic zinc-plated tubes is always critical. With HPF zinc-plated tubes can be used, there is no further painting necessary.
• Welding seams must be descaled and often be stained. Dealing with this process and substances is an environmental risk.
• Welded tubes need to be intensively cleaned inside. HPF tube assemblies do not require any special cleaning, reducing flushing time and costs during initial system startup.
• The flanging process does not cause noxious gases, thus eliminating explosion risks and fire hazards.
• The HPF tube forming is a machined cold forming process. Therefore there is no need for X-raying the connection.

Cr(VI)-free corrosion protection
All components do of course have surfaces which are free of Cr(VI) platings. Parker is highly aware of its responsibility for the environment and human health. Therefore Parker has completely renounced the use of Cr(VI) containing surfaces.

Personnel and environment-friendly
By comparing the individual operations for a welded line with Parker flanges connected lines, significant cost savings opportunities become immediately obvious. No vapours putting health at risk are released, in contrast to conventional welding processes. Consequently, usage is possible in locations with high requirements such as, for example, offshore oil platforms. In addition to this flaring machine design errors in the preparation of flanges are virtually unknown. Stress corrosion cracking generated during welding operations is history and the life of the finished tubing system is increased. Cold formed Parflange® technologies save power and energy compared to welding and require neither degreasers nor anti-corrosion agents. When galvanized tubes are used, post-galvanization can be omitted because the zinc-coating is not impaired by flaring. Parker flange connector components are delivered in state of the art Cr(VI)-free surfaces. We deliver all the component parts securely packed to the required location. Reliable delivery on the date advised. And then we come to professional assembly – our specialists will willingly take it on for you. After testing and a trial run, you can press the start button to make your production a success.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceSpecifications MetBrandApplicationConnection TypeProduct TypeFlange SizeIndustryDivisionDivisionTechnologyOptionsSpecifications MetConnection Tube Outside DiameterTube Wall ThicknessFlange SizeConnection TypeOperating Pressure
HPF448-97X12.0-ORCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERIndustrialFlange CF / Insert O-Ring NBRHydraulic Flanges3 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar97 mm12 mm3"Flange CF / Insert O-Ring NBR
HPF448-97X12.0-VCF
Backordered
POR
ISO 6164PARKERGeneral HydraulicsFlange CF / Insert F37 SealHydraulic Flanges3 inchIndustrial Manufacturing EquipmentHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar97 mm12 mm3"Flange CF / Insert F37 Seal
HPF456-101.6X16.0-FCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERIndustrialFlange CF / Insert FlatHydraulic Flanges3-1/2 inchIndustrial Manufacturing EquipmentHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar101.6 mm16 mm3 1/2"Flange CF / Insert Flat
HPF456-101.6X16.0-ORCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges3-1/2 inchMarineHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar101.6 mm16 mm3 1/2"Flange CF / Insert O-Ring NBR
HPF456-101.6X16.0-VCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERIndustrialFlange CF / Insert F37 SealHydraulic Flanges3-1/2 inchMaterial HandlingHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar101.6 mm16 mm3 1/2"Flange CF / Insert F37 Seal420 bar
HPF464-115X15.0-FCF
Backordered
POR
ISO 6162-2 (SAE J518 code 62)PARKERGeneral HydraulicsFlange CF / Insert FlatHydraulic Flanges4 inchIndustrial Manufacturing EquipmentHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar115 mm15 mm4"Flange CF / Insert Flat
HPF464-115X15.0-ORCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges4 inchMarineHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar115 mm15 mm4"Flange CF / Insert O-Ring NBR
HPF464-115X15.0-VCF
Backordered
POR
ISO 6164PARKERGeneral HydraulicsFlange CF / Insert F37 SealHydraulic Flanges4 inchMarineHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/AISO 6164 / 420 Bar115 mm15 mm4"Flange CF / Insert F37 Seal420 bar
HPF612-25X3.0-FCF
Backordered
POR
ISO 6164PARKERIndustrialFlange CF / Insert FlatHydraulic Flanges3/4 inchIndustrial Manufacturing EquipmentHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm3 mm3/4"Flange CF / Insert Flat
HPF612-25X3.0-ORCF
Backordered
POR
ISO 6162-2 (SAE J518 code 62)PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges3/4 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm3 mm3/4"Flange CF / Insert O-Ring NBR
HPF612-25X3.0-VCF
Backordered
POR
ISO 6164PARKERIndustrialFlange CF / Insert F37 SealHydraulic Flanges3/4 inchMarineHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm3 mm3/4"Flange CF / Insert F37 Seal
HPF612-25X4.0-FCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert FlatHydraulic Flanges3/4 inchMaterial HandlingHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm4 mm3/4"Flange CF / Insert Flat
HPF612-25X4.0-ORCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges3/4 inchMaterial HandlingHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm4 mm3/4"Flange CF / Insert O-Ring NBR
HPF612-25X4.0-VCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert F37 SealHydraulic Flanges3/4 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-225 mm4 mm3/4"Flange CF / Insert F37 Seal
HPF616-30X4.0-FCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERIndustrialFlange CF / Insert FlatHydraulic Flanges1 inchMaterial HandlingHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm4 mm1"Flange CF / Insert Flat
HPF616-30X4.0-ORCF
Backordered
POR
ISO 6162-2 (SAE J518 code 62)PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges1 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm4 mm1"Flange CF / Insert O-Ring NBR
HPF616-30X4.0-VCF
Backordered
POR
ISO 6164PARKERGeneral HydraulicsFlange CF / Insert F37 SealHydraulic Flanges1 inchMarineHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm4 mm1"Flange CF / Insert F37 Seal
HPF616-30X5.0-FCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERGeneral HydraulicsFlange CF / Insert FlatHydraulic Flanges1 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm5 mm1"Flange CF / Insert Flat
HPF616-30X5.0-ORCF
Backordered
POR
ISO 6164PARKERGeneral HydraulicsFlange CF / Insert O-Ring NBRHydraulic Flanges1 inchIndustrial Manufacturing EquipmentHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm5 mm1"Flange CF / Insert O-Ring NBR
HPF616-30X5.0-VCF
Backordered
POR
ISO 6162-1 (SAE J518 code 61)PARKERIndustrialFlange CF / Insert F37 SealHydraulic Flanges1 inchPower GenerationHigh Pressure Connectors Europe DivisionHigh Pressure Connectors Europe DivisionFluid & Gas HandlingN/ASAE 6000 / ISO 6162-230 mm5 mm1"Flange CF / Insert F37 Seal

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains