• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Brand
  • Compatible Element
  • Connection Type
  • Division
  • Height
  • Materials of Construction
  • Maximum Flow Rate
  • Maximum Flow Rate (m³/h)
  • Maximum Operating Pressure
More Filters...

Hyperfilter BioEnergy Natural Gas Filter

Picture for category Hyperfilter BioEnergy Natural Gas Filter

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Biogas produced in anaerobic digesters and landfills is saturated with water and contains foams, small solid particles in suspension, greases, particulates and other contaminants: it is therefore essential that these contaminants are removed from the gas by filtration prior to any downstream equipment or pipework.

Failure to remove these impurities may lead to a malfunction of devices and processes downstream and, in the absence of effective dehumidification, can cause clogging or blocking of blowers, heat exchangers and gas meters increasing maintenance costs and plant down time.

Hyperfilter BioEnergy filters have been specifically designed to prevent these undesired effects, available in a range of sizes matched to the needs of biogas applications. The secret of Hyperfilter BioEnergy is its highly advanced filter element. This combines ultra-high particle retention efficiency with extremely low pressure drop which results in clean, ready to use biogas with service costs kept to a minimum.

Features
• High efficiency filtration media

• Stainless steel housing materials (AISI304 or AISI316L) with pickling and passivation treatment

• Range of sizes to cover biogas flow rates from 105 to 110 m³/h (larger sizes available on request)

• Supplied complete with support legs for easy installation and mounting

• Top access cover to enable quick and easy element replacement

Benefits
• Maximum protection for downstream equipment and pipework significantly reducing maintenance costs and plant downtime

• Highly reliable and continuous operation even in the harshest conditions typically experienced in a biogas plant or landfill

• Very low pressure drop

Sizing and Selection
Important Note: For quoted gas purity performance, gas filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDivisionNumber of ElementsMinimum Operating TemperatureMaximum Operating TemperatureMicron RatingBrandWeightWidthMaximum Flow RateMaximum Operating PressureConnection TypeOutlet Port SizeSpecifications MetHeightApplicationCompatible ElementMaximum Flow Rate (m³/h)Port Connection InletMaterials of Construction
FFB105-304
Backordered
POR
Gas Separation and Filtration Division EMEA114 °F212 °F20 MICRONHiross32 kg440 mm61.8 CFM0.5 bargFlanged DIN EN 1092-1DN80not necessary due to low pressure1454 mmFiltration of biogasEL-FFB105-265105DN50Housing: Galvanized steel AISI304; Seals: Neopren
FFB105-316
Backordered
POR
Gas Separation and Filtration Division EMEA1-10 °C100 °C20 MICRONHiross70.55 lb17.32 inch61.8 CFM0.5 bargFlanged DIN EN 1092-1DN80not necessary due to low pressure1454 mmFiltration of biogasEL-FFB105-265105DN50Housing: Galvanized steel AISI316; Seals: Neopren
FFB1110-304
Backordered
POR
Gas Separation and Filtration Division EMEA114 °F212 °F20 MICRONHiross108 kg633 mm653.33 CFM0.5 bargFlanged DIN EN 1092-1DN300not necessary due to low pressure1883 mmFiltration of biogasEL-FFB720-1101110DN200Housing: Galvanized steel AISI304; Seals: Neopren
FFB1110-316
Backordered
POR
Gas Separation and Filtration Division EMEA114 °F212 °F20 MICRONHiross108 kg633 mm653.33 CFM0.5 bargFlanged DIN EN 1092-1DN300not necessary due to low pressure1883 mmFiltration of biogasEL-FFB720-1101110DN200Housing: Galvanized steel AISI316; Seals: Neopren
FFB265-304
Backordered
POR
Gas Separation and Filtration Division EMEA1-10 °C100 °C20 MICRONHiross35 kg17.32 inch155.97 CFM0.5 bargFlanged DIN EN 1092-1DN125not necessary due to low pressure56.06 inchFiltration of biogasEL-FFB105-265265DN80Housing: Galvanized steel AISI304; Seals: Neopren
FFB265-316
Backordered
POR
Gas Separation and Filtration Division EMEA1-10 °C100 °C20 MICRONHiross77.16 lb440 mm155.97 CFM7.25 psigFlanged DIN EN 1092-1DN125not necessary due to low pressure56.06 inchFiltration of biogasEL-FFB105-265265DN80Housing: Galvanized steel AISI316; Seals: Neopren
FFB720-304
Backordered
POR
Gas Separation and Filtration Division EMEA1-10 °C212 °F20 MICRONHiross218.26 lb24.61 inch423.78 CFM7.25 psigFlanged DIN EN 1092-1DN200not necessary due to low pressure1838 mmFiltration of biogasEL-FFB720-110720DN125Housing: Galvanized steel AISI304; Seals: Neopren
FFB720-316
Backordered
POR
Gas Separation and Filtration Division EMEA114 °F212 °F20 MICRONHiross99 kg625 mm423.78 CFM0.5 bargFlanged DIN EN 1092-1DN200not necessary due to low pressure1838 mmFiltration of biogasEL-FFB720-110720DN125Housing: Galvanized steel AISI316; Seals: Neopren

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains