Development work carried out by the CMC engineers, in conjunction with Exxon Mobil Aviation, highlighted the need for an alternative test method to determine the levels of dispersed contamination in Jet fuel. 5 years of field testing
and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding
of the contamination present in a sample. As the benchmark particle counter for use in measuring the levels of Contamination in fuels, the icountACM20, as per the UK's Energy Institute Test Method IP564, has now been included in the DEFSTAN 91-91 Issue 6 Jet Fuel Specification as a report only test alongside the current Gravimetric test method (IP423 or ASTM D5452) and Clear & Bright Visual test method
(IP216 or ASTM D2276) Product Features
• Monitors aviation fuel contamination to DEFSTAN 91-91 Issue 6 Jet A-1 fuel specification - IP654
• Multi-standard ISO cleanliness reporting
• Laser optical scanning analysis
• Fully manufactured by Parker with 20 years experience in the Particle Counter measuring market
Specifications
• 2-minute test procedure • Latest averaging software as standard • Downloader software
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Fluid TemperatureSensing MethodWeightOperating TemperatureMinimum Fluid TemperatureTechnologyLengthIngress Protection RatingCycle TimeIndustryFor Fluid TypeElectrical RequirementsDivisionProduct TypePort TypeHeightATEX Specifications MetOperating PressureAccuracyWidthBody MaterialCommunication InterfaceFlow RateDivisionSeal MaterialSpecifications MetProduct StylePort SizeOperating HumidityMaterials of ConstructionBrandCertificatesFlow Capacity (l/min)Connection StyleOptionsModel Number
ACM202022EUR
Backordered
POR
176 °FLaser8 kg5 to 40 °C5 °CFiltration178 mmN/A< 2 minOil & GasDiesel12VDC input, 6 x 'D' cell batteries, rechargeable battery packHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a29 to 6000 psi< 7 %178 mmStainless SteelUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCE CertificationParticle Detector/CounterM16n/aStainless Steel armoured endsPARKERIP55380Electrical EUEUR202022
ACM202022UK
Backordered
POR
80 °CLaser8 kg41 to 104 °F41 °FFiltration240 mmN/A< 2 minOil & GasDiesel110 to 240 VACHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a2 to 420 bar< 7 %178 mmBRASSUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonIP564:2020Particle Detector/CounterM16n/aStainless Steel armoured endsPARKERIP55380Electrical UKUK202022
ACM202022US
Backordered
POR
176 °FLaser15 kg41 to 104 °F41 °FFiltration240 mmN/A< 2 minAerospaceJet Fuel12VDC input, 6 x 'D' cell batteries, rechargeable battery packHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a29 to 6000 psi< 7 %178 mmBRASSUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCE CertificationParticle Detector/CounterM16n/aHousing: NylonPARKERIP55380Electrical USUS202022
ACM202024EUR
Backordered
POR
80 °CLaser15 kg5 to 40 °C41 °FFiltration240 mmN/A< 2 minAerospaceJet Fuel110 to 240 VACHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a2 to 420 bar< 7 %178 mmBRASSUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonIP564:2020Particle Detector/CounterM16n/aHousing: NylonPARKERIP55380Electrical EUEUR202024
ACM202024UK
Backordered
POR
176 °FLaser8 kg5 to 40 °C41 °FFiltration240 mmN/A< 2 minOil & GasJet Fuel12VDC input, 6 x 'D' cell batteries, rechargeable battery packHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a29 to 6000 psi< 7 %178 mmStainless SteelUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCE CertificationParticle Detector/CounterM16n/aHousing: NylonPARKERIP55380Electrical UKUK202024
ACM202024US
Backordered
POR
80 °CLaser8 kg41 to 104 °F41 °FFiltration240 mmN/A< 2 minOil & GasDiesel12VDC input, 6 x 'D' cell batteries, rechargeable battery packHydraulic & Industrial Process Filtration Division EMEACondition MonitorMetric277 mmn/a2 to 420 bar< 7 %178 mmBRASSUSB Port380 L/minHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCE CertificationParticle Detector/CounterM16n/aStainless Steel armoured endsPARKERIP55380Electrical UKUS202024