*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Specifications Met | Division | Coil Temperature Range | Coil Power Consumption | Power Supply Voltage | Insulation Class | Electrical Connection | Coil Type | ATEX Specifications Met | Maximum Ambient Temperature | Minimum Ambient Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
482605C2 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to 50 °C | 5 W | 24V DC | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 | +50°C | -40°C | |
4826060A | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2 W | 110-115V 50Hz | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
4826061603D | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2 W | 220-230V 50Hz | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 6 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
482606160C2 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2.5 W | 24V DC | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 6 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
4826063D | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2 W | 220-230V 50Hz | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
482606A2 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2 W | 24V 50Hz | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
482606A4 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2 W | 48V 50Hz | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
482606C1 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2.5 W | 12VDC | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
482606C2 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to +85 / +65 °C | 2.5 W | 24V DC | F 155 °C | Cable connection (3 x 0.75 mm²) encapsulated with coil, cable material according to application. 1.5 m cable length | ELECTRICAL PART LOW POWER 22 mm | II 2 G - Ex mb IIC T4 / T5 | +85°C / +65°C | -40°C | |
48287001N7 | Backordered | POR | CE | Fluid and Climate Controls Europe | -40 to 65 °C | 0.3 to 3 W | 28V DC | H 180°C | Cable connection through a stainless steel cable gland M20 x 1.5 allowing use of cable diameter from 10 to 12 mm. | ELECTRICAL PARTS "IS" 50 mm | II 1 G - Ex ia IIC - T6 | +65°C | -40°C | |
4833710A | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 110-115V 50Hz | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
4833713D | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 220-230V 50Hz | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
4833714K | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 220-240V 60Hz | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371A2 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 24V 50Hz | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371B2 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 24V 60Hz | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371C1 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 12VDC | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371C2 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 24V DC | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371C5 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 110V DC | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
483371C7 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 65 °C | 8 W | 220V DC | F 155 °C | By special cable gland or M20 x 1.5 "Ex eb" on screw terminals for wires up to 1.5 mm². Cables with outside diameter | ELECTRICAL PARTS 50 MM | II 2 G - Ex eb Iic T4 | +65°C | -40°C | |
48358001N7 | Backordered | POR | CE - EAC | Fluid and Climate Controls Europe | -40 to 55 °C | 3 W | 28V DC | F 155 °C | 2 P + E plug according to EN 175301-803 type A | ELECTRICAL PARTS 32 mm "IS" | II 1 G Ex ia IIC T6 | +55°C | -40°C |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.