• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature
  • Application
  • Brand
  • Connection Type
  • Depth
  • Division
  • Division
  • Electrical Requirements
  • Flow Rate
  • Height
More Filters...

K-MT 10-95 Series Heatless Compressed Air Dryer

Picture for category K-MT 10-95 Series Heatless Compressed Air Dryer

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker K-MT 10-95 range of heatless adsorption dryers are designed to dry industrial compressed air reliably and efficiently down to a pressure dew point of -70°C. The units are compact and are designed to be installed free standing. They come equipped with integrated high performance OIL-X pre- and post filtration and are capable of volume flows up to 940 m³/h @ 7 barg (100 psig).

Features
• Pressure dew points down to -70°C

• Volume flows up to 940m³/h @ 7 barg (3600 cfm @ 102 psig)

• High performance OIL-X pre- and post filters installed as standard

• Energy saving dew point dependent switching (DDS) as an option

Benefits
• Highest quality air

• Energy efficient

• Very flexible due to a wide range of options and accessories

Energy Savings
Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option. In such an operating mode, the changeover cycle between chambers only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated chamber occur. This feature enables the drying phase to be lengthened and thus avoids unnecessary use of purge air for regeneration and consequently provides energy savings.

Compressed air can be selectively dried to meet a dew point of -25°C down to -70°C.

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceDepthOperating TemperatureApplicationOperating PressureIngress Protection RatingHeightSpecifications MetIndustryAmbient TemperatureBrandISO GradeProduct StyleProduct SeriesElectrical RequirementsWeightDivisionDivisionNoise LevelProduct TypeConnection TypeWidthTechnologyOptional AccessoriesPort SizeFlow Rate
K10/16D3-G230M
Backordered
POR
466.0 mm41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only56 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC355 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1118.0 mmFiltrationNone1 inch105 m³/h @7 barg (62 cfm @102 psig)
K10/16D3-G230MT
Backordered
POR
466.0 mm5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only1411.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC161 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1118.0 mmFiltrationPre-installed Dew Point Sensor1 inch105 m³/h @7 barg (62 cfm @102 psig)
K15/16D3-G230M
Backordered
POR
18 inch5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only1740.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC193 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1118.0 mmFiltrationNone1 inch145 m³/h @7 barg (85 cfm @102 psig)
K15/16D3-G230MT
Backordered
POR
18 inch5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only69 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC425 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1118.0 mmFiltrationPre-installed Dew Point Sensor1 inch145 m³/h @7 barg (85 cfm @102 psig)
K20/16D3-G230M
Backordered
POR
18 inch41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only60 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC425 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP37 inchFiltrationNone1 inch200 m³/h @7 barg (118 cfm @102 psig)
K20/16D3-G230MT
Backordered
POR
466.0 mm5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only60 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC425 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP37 inchFiltrationPre-installed Dew Point Sensor1 inch200 m³/h @7 barg (118 cfm @102 psig)
K25/16D3-G230M
Backordered
POR
506.0 mm41 to 122 °FCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only68 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC234 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP36 inchFiltrationNone1½ inch255 m³/h @7 barg (150 cfm @102 psig)
K25/16D3-G230MT
Backordered
POR
20 inch41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only1735.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC234 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP926.0 mmFiltrationPre-installed Dew Point Sensor1½ inch255 m³/h @7 barg (150 cfm @102 psig)
K35/16D3-G230M
Backordered
POR
534.0 mm41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only1783.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC283 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1213.0 mmFiltrationNone1½ inch350 m³/h @7 barg (206 cfm @102 psig)
K35/16D3-G230MT
Backordered
POR
21 inch5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only70 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC624 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1213.0 mmFiltrationPre-installed Dew Point Sensor1½ inch350 m³/h @7 barg (206 cfm @102 psig)
K45/16D3-G230M
Backordered
POR
555.0 mm41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only71 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC334 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP49 inchFiltrationNone1½ inch420 m³/h @7 barg (247 cfm @102 psig)
K45/16D3-G230MT
Backordered
POR
555.0 mm5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only71 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC334 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP1245.0 mmFiltrationPre-installed Dew Point Sensor1½ inch420 m³/h @7 barg (247 cfm @102 psig)
K60/16D3-G230M
Backordered
POR
24 inch41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only73 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC944 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP51 inchFiltrationNone2 inch620 m³/h @7 barg (365 cfm @102 psig)
K60/16D3-G230MT
Backordered
POR
607.0 mm5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only73 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC428 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP51 inchFiltrationPre-installed Dew Point Sensor2 inch620 m³/h @7 barg (365 cfm @102 psig)
K75/16D3-G230M
Backordered
POR
628.0 mm41 to 122 °FCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only78 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC555 kgGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP57 inchFiltrationNone2 inch750 m³/h @7 barg (441 cfm @102 psig)
K75/16D3-G230MT
Backordered
POR
25 inch5 to 50 °CCompressed Air Applications58 to 232 psigIP65 Indoor and Frost Free Installation Only78 inchPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC1224 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP57 inchFiltrationPre-installed Dew Point Sensor2 inch750 m³/h @7 barg (441 cfm @102 psig)
K95/16D3-G230M
Backordered
POR
658.0 mm41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only2001.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental122.0 °F MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC1589 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP59 inchFiltrationNone2½ inch940 m³/h @7 barg (553 cfm @102 psig)
K95/16D3-G230MT
Backordered
POR
658.0 mm41 to 122 °FCompressed Air Applications4 to 16 bargIP65 Indoor and Frost Free Installation Only2001.0 mmPED 2014/68/EU Fluid Group II<br/> Others on request.Industrial Manufacturing Equipment<br/>Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental50.0 °C MaximumPARKERStandard: Class 2.2.2<br/> Options: Class 2.1.2 or Class 2.3.2HeatlessK-MT 10-95Standard:<br/>230V 1ph 50/60Hz<br/><br/>Options:<br/>115V 1ph 50/60Hz<br/>or 24V DC1589 lbGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA65 to 86 dBACompressed Air DryerBSPP59 inchFiltrationPre-installed Dew Point Sensor2½ inch940 m³/h @7 barg (553 cfm @102 psig)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains