KE-MT Series Large Flow Heatless Compressed Air Dryer

Picture for category KE-MT Series Large Flow Heatless Compressed Air Dryer

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker KE-MT Series heatless adsorption dryers are designed to supply high quality dry compressed air reliably and efficiently down to a pressure dew point of -70 °C. They are capable of volume flows of up to 6100m³/h at operating conditions of 7 barg (100psig).

The KE-MT Series is offered with energy saving dew point dependent switching (DDS) as an option. Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available. In such an operating mode, the changeover cycle between vessels only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated vessel occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration and consequently provides significant energy savings.

When there is a further requirement for compressed air to be delivered free from oil vapour and odours, as well as clean and dry, the units can be supplied with an additional third vessel filled with activated carbon, the KEA-MT Series. KEA-MT is ideal for use in laboratory, food, beverage and pharmaceutical applications.

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the product information sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceController TypePressure Dew PointDepthMaximum Operating TemperatureMaximum Ambient TemperaturePort SizePower ConsumptionElectrical RequirementsMinimum Ambient TemperatureMinimum Operating TemperatureHeightConnection TypeMaximum Flow RateMinimum Operating PressureProduct TypeBrandWeightCompatible After FilterWidthMaximum Operating PressureCompatible PrefilterIngress Protection RatingDivisionSpecifications MetPre-Installed Optional AccessoriesMaximum Flow Rate (m³/h)
K120/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F840 mm122 °F50 °CDN507.2 VA230V, 50-60Hz1.5 °C25 °C2080 mmFlanged according to EN1092-1706 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER640 kgOIL-X AOPX050I1060 mm145 psigOIL-X AOPX050I and AAPX050I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A1200 @ 7 barg / PDP -25°C
K120/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F840 mm50 °C50 °CDN507.2 VA230V, 50-60Hz1.5 °C77 °F2080 mmFlanged according to EN1092-1706 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER640 kgOIL-X AOPX050I1060 mm10 bargOIL-X AOPX050I and AAPX050I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor1200 @ 7 barg / PDP -25°C
K150/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F900 mm50 °C50 °CDN657.2 VA230V, 50-60Hz1.5 °C77 °F2120 mmFlanged according to EN1092-1912 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER770 kgOIL-X AOPX050I1270 mm10 bargOIL-X AOPX050I and AAPX050I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A1550 @ 7 barg / PDP -25°C
K150/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F900 mm50 °C50 °CDN657.2 VA230V, 50-60Hz1.5 °C25 °C2120 mmFlanged according to EN1092-1912 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER770 kgOIL-X AOPX050I1270 mm10 bargOIL-X AOPX050I and AAPX050I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor1550 @ 7 barg / PDP -25°C
K200/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F990 mm50 °C50 °CDN657.2 VA230V, 50-60Hz1.5 °C77 °F2160 mmFlanged according to EN1092-11177 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER955 kgOIL-X AOPX055I1350 mm10 bargOIL-X AOPX055I and AAPX055I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A2000 @ 7 barg / PDP -25°C
K200/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F990 mm122 °F50 °CDN657.2 VA230V, 50-60Hz1.5 °C77 °F2160 mmFlanged according to EN1092-11177 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER955 kgOIL-X AOPX055I1350 mm10 bargOIL-X AOPX055I and AAPX055I54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor2000 @ 7 barg / PDP -25°C
K250/10D1-F230M
Backordered
POR
Multitronic-25 to -70 °C1040 mm122 °F50 °CDN807.2 VA230V, 50-60Hz1.5 °C77 °F2210 mmFlanged according to EN1092-11471 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER1075 kgOIL-X AOPX060K1530 mm145 psigOIL-X AOPX060K and AAPX060K54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A2500 @ 7 barg / PDP -25°C
K250/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F1040 mm50 °C50 °CDN807.2 VA230V, 50-60Hz1.5 °C25 °C2210 mmFlanged according to EN1092-11471 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER1075 kgOIL-X AOPX060K1530 mm145 psigOIL-X AOPX060K and AAPX060K54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor2500 @ 7 barg / PDP -25°C
K300/10D1-F230M
Backordered
POR
Multitronic-25 to -70 °C1100 mm122 °F50 °CDN807.2 VA230V, 50-60Hz1.5 °C77 °F2255 mmFlanged according to EN1092-11766 CFM at 101 psig, PDP -13°F72.5 psigHeatlessPARKER1500 kgOIL-X AOPX060K1600 mm145 psigOIL-X AOPX060K and AAPX060K54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A3000 @ 7 barg / PDP -25°C
K300/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F1100 mm50 °C50 °CDN807.2 VA230V, 50-60Hz1.5 °C25 °C2255 mmFlanged according to EN1092-11766 CFM at 101 psig, PDP -13°F72.5 psigHeatlessPARKER1500 kgOIL-X AOPX060K1600 mm145 psigOIL-X AOPX060K and AAPX060K54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor3000 @ 7 barg / PDP -25°C
K380/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F1200 mm122 °F50 °CDN1007.2 VA230V, 50-60Hz1.5 °C25 °C2385 mmFlanged according to EN1092-12237 CFM at 101 psig, PDP -13°F72.5 psigHeatlessPARKER1990 kgOIL-X AO070O1875 mm10 bargOIL-X AO070O and AA070O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A3800 @ 7 barg / PDP -25°C
K380/10D1-F230MT
Backordered
POR
Multitronic-25 to -70 °C1200 mm50 °C50 °CDN1007.2 VA230V, 50-60Hz1.5 °C77 °F2385 mmFlanged according to EN1092-12237 CFM at 101 psig, PDP -13°F72.5 psigHeatlessPARKER1990 kgOIL-X AO070O1875 mm145 psigOIL-X AO070O and AA070O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor3800 @ 7 barg / PDP -25°C
K500/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F1250 mm50 °C50 °CDN1007.2 VA230V, 50-60Hz1.5 °C25 °C2660 mmFlanged according to EN1092-12855 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER2410 kgOIL-X AO075O1925 mm10 bargOIL-X AO075O and AA075O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A4850 @ 7 barg / PDP -25°C
K500/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F1250 mm50 °C50 °CDN1007.2 VA230V, 50-60Hz1.5 °C77 °F2660 mmFlanged according to EN1092-12855 CFM at 101 psig, PDP -13°F72.5 psigHeatlessPARKER2410 kgOIL-X AO075O1925 mm145 psigOIL-X AO075O and AA075O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor4850 @ 7 barg / PDP -25°C
K600/10D1-F230M
Backordered
POR
Multitronic-13 to -97 °F1565 mm122 °F50 °CDN1257.2 VA230V, 50-60Hz1.5 °C77 °F2820 mmFlanged according to EN1092-13590 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER2850 kgOIL-X AO075O2160 mm10 bargOIL-X AO075O and AA075O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestN/A6100 @ 7 barg / PDP -25°C
K600/10D1-F230MT
Backordered
POR
Multitronic-13 to -97 °F1565 mm122 °F50 °CDN1257.2 VA230V, 50-60Hz1.5 °C77 °F2820 mmFlanged according to EN1092-13590 CFM at 101 psig, PDP -13°F5 bargHeatlessPARKER2850 kgOIL-X AO075O2160 mm10 bargOIL-X AO075O and AA075O54Gas Separation and Filtration Division EMEAPED 97/23/EG Module D+B Category II, others on requestDew Point Sensor6100 @ 7 barg / PDP -25°C

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains