MICROGUARD HT - High Temperature HEPA Filters

Picture for category MICROGUARD HT - High Temperature HEPA Filters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker MICROGUARD® HT product line is comprised of standard and high capacity filters. Designed for use in higher air flow applications up to 500 FPM, Parker MICROGUARD® 2000 filters deliver HEPA filtration efficiency at 99.97%, 99.99%, and 99.999% on 0.3 micron particles.
For renovations and upgrades, the selection of these high capacity filters means longer service life, lower maintenance expenses, and less disposal cost. State-of-the-art engineering utilizes a unique score fold pleat design that increases media surface area and reduces opportunities for media damage during handling.

MICROGUARD media is a continuous sheet of laid paper produced from glass microfibers which is subject to 11 distinct tests and inspections prior to shipment.

Markets
•Commercial and Industrial HVAC
•Process Air Filtration
Applications
•Hotels and entertainment complexes
•Food processing
•Microelectronics manufacturing
•Data centers
•Commercial office buildings
•Schools and universities
•Clean manufacturing facilities
•Hospitals and healthcare facilities
•Government institutions
•Laboratories
•Industrial manufacturing
Benefits
•Proprietary E-Pleat® media technology efficiently directs air flow through the filter
•Offers longer service life and fewer filter change-outs with higher dust holding capacity
•Energy savings – Lower pressure drop than standard filters due to highly refined media and E-pleat design.
•Completely incinerable with high impact polystyrene (HIPS) frame
•High capacity pleat configurations allow the filters to be installed in line with other filters in the air handling system without the need to costly transitions.
Features
•Filtration efficiency rating: MERV 13 -16
•Depth (in.): 11 ½
•Construction: Available in box and single header
•Materials of construction: 24-gauge metal or high-impact polystyrene (HIPS) frame, synthetic media with embossed design
•Maximum operating temperature, plastic 170 °F (77 °C)
•Maximum operating temperature, metal 180 °F (82 °C)
•Rated face velocity: 500 FPM
•Recommended final resistance: 1.50” W.G.
•Classified per UL Standard 900 for Flammability
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMicron RatingActual DepthIndustryActual WidthActual HeightFlow RatePackage QuantityPleat Separator TypeTechnologyFor Fluid TypeApplicationFilter Efficiency RatingFilter MaterialRated Air VelocityTest MethodWeightProduct TypeMaximum Operating TemperatureDivisionSpecifications MetInitial ResistanceFilter AreaSeal TypeMaterials of ConstructionProduct StyleBrandGasket MaterialDivisionAir Filter Frame/Header TypeModel NumberNominal Size
2971588
Backordered
POR
99.97% : 0.3 micron Particulate (Overall)11.5 inchHVAC and Refrigeration23.375 inch23.375 inch1000 CFM1Corrugated Aluminum SeparatorsFiltrationAirAir FiltrationHEPAMicroglass Dual Phase Fiber125 ft/minIndividually Tested per IEST-RP-CC00145 lbHigh Efficiency Particulate Air Filters500 °FHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability1.1 in wg188 ft2High Temp. Red Silicone16 Gauge 304 Stainless SteelHEPA Frame SystemPARKER1/4" (D) x 3/4" (W) High Temp. Red Silicone Gasket, Air Leaving SideHVAC Filtration DivisionDouble Turned FlangeH2323B33-0JBB2900023-3/8 x 23-3/8 x 11-1/2 (HxWxD)
2977695
Backordered
POR
99.97% : 0.3 micron Particulate (Overall)11.5 inchHVAC and Refrigeration24 inch24 inch1000 CFM1Corrugated Aluminum SeparatorsFiltrationAirAir FiltrationHEPAMicroglass Dual Phase Fiber125 ft/minIndividually Tested per IEST-RP-CC00145 lbHigh Efficiency Particulate Air Filters500 °FHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability1 in wg201 ft2High Temp. Red Silicone16 Gauge 304 Stainless SteelHEPA Frame SystemPARKER1/4" (D) x 3/4" (W) High Temp. Red Silicone Gasket, Air Leaving SideHVAC Filtration DivisionDouble Turned FlangeH2424B00-0JBB2900024 x 24 x 11-1/2 (HxWxD)
2978302
Backordered
POR
99.97% : 0.3 micron Particulate (Overall)11.5 inchHVAC and Refrigeration12 inch24 inch1000 CFM1Corrugated Aluminum SeparatorsFiltrationAirAir FiltrationHEPAMicroglass Dual Phase Fiber500 ft/minIndividually Tested per IEST-RP-CC00132 lbHigh Efficiency Particulate Air Filters500 °FHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability1.35 in wg141 ft2High Temp. Red Silicone16 Gauge 304 Stainless SteelHEPA Frame SystemPARKER1/4" (D) x 3/4" (W) High Temp. Red Silicone Gasket, Air Leaving SideHVAC Filtration DivisionDouble Turned FlangeH2412B00-0JBB2900F24 x 12 x 11-1/2 (HxWxD)
2979056
Backordered
POR
99.97% : 0.3 micron Particulate (Overall)11.5 inchHVAC and Refrigeration12 inch24 inch500 CFM1Corrugated Aluminum SeparatorsFiltrationAirAir FiltrationHEPAMicroglass Dual Phase Fiber125 ft/minIndividually Tested per IEST-RP-CC00130 lbHigh Efficiency Particulate Air Filters500 °FHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability1 in wg94 ft2High Temp. Red Silicone16 Gauge 304 Stainless SteelHEPA Frame SystemPARKER1/4" (D) x 3/4" (W) High Temp. Red Silicone Gasket, Air Leaving SideHVAC Filtration DivisionDouble Turned FlangeH2412B00-0JBB2900024 x 12 x 11-1/2 (HxWxD)
2979820
Backordered
POR
99.97% : 0.3 micron Particulate (Overall)11.5 inchHVAC and Refrigeration11.375 inch23.375 inch1000 CFM1Corrugated Aluminum SeparatorsFiltrationAirAir FiltrationHEPAMicroglass Dual Phase Fiber500 ft/minIndividually Tested per IEST-RP-CC00138 lbHigh Efficiency Particulate Air Filters500 °FHVAC Filtration DivisionClassified Per UL Standard 900 for Flammability1.35 in wg120 ft2High Temp. Red Silicone16 Gauge 304 Stainless SteelHEPA Frame SystemPARKER1/4" (D) x 3/4" (W) High Temp. Red Silicone Gasket, Air Leaving SideHVAC Filtration DivisionDouble Turned FlangeH2311B33-0JBB2900F23-3/8 x 11-3/8 x 11-1/2 (HxWxD)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains