MICROGUARD LR - Low-Resistance Sub-HEPA Filters

Picture for category MICROGUARD LR - Low-Resistance Sub-HEPA Filters

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker MICROGUARD® LR product line is comprised of four standard sizes. All filters utilize proprietary E-Pleat® media technology, which molds filtration media into a series of pre-formed channels that direct the air smoothly through the filter, allowing for even loading and complete media utilization.
This product provides 98.5% removal efficiency on 0.3 micron particulate low resistance. E-pleat media technology MICROGUARD LR can be used in a wide range of high efficiency air requirements to replace typical MERV 13-16 applications, also in mist collection systems for turning, milling and grinding machinery processes using soluble oil and even water-based cooling fluids.
The high-impact polystyrene (HIPS) frame resists cracking and is not affected by corrosion. The media resists tearing, damage, moisture and microbial growth. The filter is also completely incinerable, which minimizes waste disposal costs. Metal cell versions of the product are for use with standard HEPA frame systems.

Markets

• Commercial and Industrial HVAC
• Process Air Filtration

Applications
•Hotels and entertainment complexes
•Food processing
•Microelectronics manufacturing
•Data centers
•Commercial office buildings
•Schools and universities
•Clean manufacturing facilities
•Hospitals and healthcare facilities
•Government institutions
•Laboratories
•Industrial manufacturing
Benefits
?Proprietary E-Pleat® media technology efficiently directs air flow through the filter
?Offers longer service life and fewer filter change-outs with higher dust holding capacity
?Energy savings – Lower pressure drop than standard filters due to highly refined media and E-pleat design.
?Completely incinerable with high impact polystyrene (HIPS) frame
?High capacity pleat configurations allow the filters to be installed in line with other filters in the air handling system without the need to costly transitions.
Features
?Filtration efficiency rating: 98.5% on 0.3 micron
?Depth (in.): 11 ½
?Construction: Available in box and single header
?Materials of construction: 16-gauge metal or high-impact polystyrene (HIPS) frame, synthetic media with embossed design
?Maximum operating temperature, plastic 170 °F (77 °C)
?Maximum operating temperature, metal 180 °F (82 °C)
?Rated face velocity: 500 FPM
?Recommended final resistance: 1.50” W.G. for typical HVAC systems
Twice initial resistance for HEPA applications
?Classified per UL Standard 900 for Flammability
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceProduct StyleFilter Efficiency RatingIndustryInitial ResistanceRated Air VelocityMaterials of ConstructionFilter AreaSeal TypeActual DepthMicron RatingModel NumberPleat Separator TypeTechnologyActual WidthProduct TypeApplicationDivisionGasket MaterialMaximum Operating TemperatureFor Fluid TypeSpecifications MetPackage QuantityWeightActual HeightFilter MaterialTest MethodBrandDivisionFlow RateAir Filter Frame/Header TypeNominal SizeWidth (inch)Media Area (sq. ft.)Depth (inch)Nominal Size (inch)Weight (lbs)Maximum Operating Temperature (F)Height (inch)
2959183
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration1.05 in wg500 ft/minHigh-Impact Polystyrene Plastic69 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK1919B33-0PA14000EBead Separator PacksFiltration19.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket on One Vertical Side of Header170 °FAirClassified Per UL Standard 900 for Flammability18 lb19.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1400 CFM3/4" x 3/4" Single Header on Air Entry Side19-3/8 x 19-3/8 x 11-1/2 (HxWxD)
2959184
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration1.05 in wg500 ft/minHigh-Impact Polystyrene Plastic83 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2319B33-0PA14000EBead Separator PacksFiltration19.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket on One Vertical Side of Header170 °FAirClassified Per UL Standard 900 for Flammability110 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1650 CFM3/4" x 3/4" Single Header on Air Entry Side23-3/8 x 19-3/8 x 11-1/2 (HxWxD)
2959185
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration1.05 in wg500 ft/minHigh-Impact Polystyrene Plastic49 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2311B33-0PA14000EBead Separator PacksFiltration11.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket on One Vertical Side of Header170 °FAirClassified Per UL Standard 900 for Flammability16 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1000 CFM3/4" x 3/4" Single Header on Air Entry Side23-3/8 x 11-3/8 x 11-1/2 (HxWxD)
2959186
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration1.05 in wg500 ft/minHigh-Impact Polystyrene Plastic101 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2323B33-0PA14000EBead Separator PacksFiltration23.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket on One Vertical Side of Header170 °FAirClassified Per UL Standard 900 for Flammability112 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division2000 CFM3/4" x 3/4" Single Header on Air Entry Side23-3/8 x 23-3/8 x 11-1/2 (HxWxD)
2959383
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/minHigh-Impact Polystyrene Plastic79 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK1919B33-0P000000EBead Separator PacksFiltration19.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket, Air Leaving Side170 °FAirClassified Per UL Standard 900 for Flammability18 lb19.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1400 CFMPlastic Frame Panels19-3/8 x 19-3/8 x 11-1/2 (HxWxD)
2959384
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/minHigh-Impact Polystyrene Plastic95 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2319B33-0P000000EBead Separator PacksFiltration19.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket, Air Leaving Side170 °FAirClassified Per UL Standard 900 for Flammability110 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1650 CFMPlastic Frame Panels23-3/8 x 19-3/8 x 11-1/2 (HxWxD)
2959385
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/minHigh-Impact Polystyrene Plastic56 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2311B33-0P000000EBead Separator PacksFiltration11.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket, Air Leaving Side170 °FAirClassified Per UL Standard 900 for Flammability16 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1000 CFMPlastic Frame Panels23-3/8 x 11-3/8 x 11-1/2 (HxWxD)
2959386
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/minHigh-Impact Polystyrene Plastic116 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2323B33-0P000000EBead Separator PacksFiltration23.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Neoprene Gasket, Air Leaving Side170 °FAirClassified Per UL Standard 900 for Flammability112 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division2000 CFMPlastic Frame Panels23-3/8 x 23-3/8 x 11-1/2 (HxWxD)23.37513011.524x24x1219.516023.375
2959585
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.66 in wg500 ft/min24 Gauge Galvanized Steel61 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2412B00-0EG00000EBead Separator PacksFiltration12 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Urethane Gasket, Air Leaving Side180 °FAirClassified Per UL Standard 900 for Flammability116 lb24 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1000 CFMMetal C-Style Box24 x 12 x 11-1/2 (HxWxD)
2959586
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.66 in wg500 ft/min24 Gauge Galvanized Steel122 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2424B00-0EG00000EBead Separator PacksFiltration24 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Urethane Gasket, Air Leaving Side180 °FAirClassified Per UL Standard 900 for Flammability122 lb24 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division2000 CFMMetal C-Style Box24 x 24 x 11-1/2 (HxWxD)2412211.524x24x1230.118024
2959587
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/min24 Gauge Galvanized Steel116 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2323B33-0EG00000EBead Separator PacksFiltration23.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Urethane Gasket, Air Leaving Side180 °FAirClassified Per UL Standard 900 for Flammability120 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division2000 CFMMetal C-Style Box23-3/8 x 23-3/8 x 11-1/2 (HxWxD)
2959588
Backordered
POR
HEPA Frame SystemSub-HEPAHVAC and Refrigeration0.75 in wg500 ft/min24 Gauge Galvanized Steel56 ft2Urethane Sealant11.5 inch98.5% : 0.3 micron ParticulateK2311B33-0EG00000EBead Separator PacksFiltration11.375 inchHigh Efficiency Particulate Air FiltersAir FiltrationHVAC Filtration Division1/4" (D) x 3/4" (W) Urethane Gasket, Air Leaving Side180 °FAirClassified Per UL Standard 900 for Flammability114 lb23.375 inchSyntheticPAO Penetraion TestingPARKERHVAC Filtration Division1000 CFMMetal C-Style Box23-3/8 x 11-3/8 x 11-1/2 (HxWxD)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains