*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Valve Configuration | Materials of Construction | Seat Material | Connection Size | ANSI Flange Class | Bore Diameter | Configuration | Division | Flange Face Type | Minimum Operating Temperature | Industry Application | Maximum Operating Pressure | Specifications Met | Handle Type | Flange Size | Maximum Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PBY100B32T1500 | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 1500 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Ring Type Joint | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 248 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 2" inch | 204 °C | |
PBY100B32T1500F | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 1500 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Ring Type Joint | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 248 bar | Fire Safe | Stainless Steel Lever | 2" inch | 204 °C | |
PBY100B8F150 | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 150 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 275 psi | N/A | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F150F | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 150 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -29 °C | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 19 bar | Fire Safe | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F150N | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 150 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -29 °C | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 19 bar | NACE | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F2500 | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 2500 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 414 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F2500F | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | 1/2" NPT F inch | 2500 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -29 °C | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 6000 psi | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F300 | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 300 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 50 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F300N | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | 1/2" NPT F inch | 300 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 50 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 204 °C | |
PBY100B8F600 | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | Flange x NPTF | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 1440 psi | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100B8F600N | Backordered | POR | Flange x Screw | 316 Stainless Steel | PTFE | 1/2" NPT F inch | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 99 bar | NACE | Stainless Steel Lever | 1/2" inch | 204 °C | |
PBY100E16F150F | Backordered | POR | Flange x Screw | Duplex | PTFE | Flange x NPTF | 150 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -29 °C | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 290 psi | Fire Safe | Stainless Steel Lever | 1" inch | 400 °F | |
PBY100E16F600N | Backordered | POR | Flange x Screw | Duplex | PTFE | Flange x NPTF | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 103 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1" inch | 204 °C | |
PBY100E8F300 | Backordered | POR | Flange x Screw | Duplex | PTFE | Flange x NPTF | 300 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -29 °C | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 52 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100E8F600 | Backordered | POR | Flange x Screw | Duplex | PTFE | Flange x NPTF | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 103 bar | N/A | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100H12F150 | Backordered | POR | Flange x Screw | Carbon Steel | PTFE | 1/2" NPT F inch | 150 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 20 bar | N/A | Stainless Steel Lever | 3/4" inch | 400 °F | |
PBY100H16F600F | Backordered | POR | Flange x Screw | Carbon Steel | PTFE | Flange x NPTF | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 102 bar | Fire Safe | Stainless Steel Lever | 1" inch | 204 °C | |
PBY100H8F600N | Backordered | POR | Flange x Screw | Carbon Steel | PTFE | Flange x NPTF | 600 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Raised Face Spiral | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 1480 psi | NACE | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100H8T1500 | Backordered | POR | Flange x Screw | Carbon Steel | PTFE | 1/2" NPT F inch | 1500 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Ring Type Joint | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 3705 psi | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 400 °F | |
PBY100H8T900 | Backordered | POR | Flange x Screw | Carbon Steel | PTFE | Flange x NPTF | 900 | 10 mm | Ball-Needle-Ball | Instrumentation Products Division | Ring Type Joint | -20 °F | Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process Sampling | 153 bar | API 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312 | Stainless Steel Lever | 1/2" inch | 204 °C |
REWARD Status
Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.