• Availability & Price
  • Search SKU
Filter by attributes
  • Bore Diameter
  • Connection Type
  • Division
  • Maximum Operating Pressure
  • Maximum Working Pressure (psi)
  • Stem Type
  • Tube O.D. (mm)
  • Tube Outside Diameter
  • Valve Type
More Filters...

Needle Valve, High Presssure - VM Series 100,000 PSI

Picture for category Needle Valve, High Presssure - VM Series 100,000 PSI

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Autoclave's 100VM Series needle valves are a non-rotating rising stem design, working pressures to 100,000 psi (6895 bar). The tubing sizes range from ¼” to 9/16”. Tubing connections utilize the Parker Autoclave cone and thread design. Standard high pressure needle valves with PTFE packing may be operated from 0°F (-17.8°C) to 450°F (232°C) and to 230°F (110°C) with nylon-leather packing. These high pressure needle valves have adjustable packing below the threads to eliminate the media from contacting the power threads, and causing galling during actuation

Along with their many features these valves provide dependable and trouble free service in wide variety of applications.

Markets:
• Oil and Gas
• Petrochemical

Features/Benefits:
• Tubing sizes are 1/4 “ to  9/16”.
• Non-rotating stem prevents stem/seat galling.
• Rising stem/barstock body design.
• Metal-to-metal seating achieves bubble-tight shut-off, longer stem/seat life in abrasive flow, greater durability for repeated on/off cycles and excellent corrosion resistance.
• For dependable stem and body sealing , valves are furnished with PTFE encapsulated packing.
• Stem sleeve and packing gland materials have been selected to achieve extended thread cycle life and reduced handle torque.
• Choice of Vee or Regulating stem tips.
• Choice of three body patterns


Applications:
• High Pressure Skid Panels
• High Pressure Fluid Handling Systems
• Research Systems
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceConnection TypeMaximum Operating PressureTube Outside DiameterDivisionBore DiameterTube O.D. (mm)Stem TypeMaximum Working Pressure (psi)Valve Type
30VM9083
Backordered
POR
F562C2068 bar9/16 inchInstrumentation Products Division3.18 mm14.29 mmREG30,0003-Way / 2 on Pressure
30VM9084
Backordered
POR
F562C2068 bar9/16 inchInstrumentation Products Division3.18 mm14.29 mmREG30,0003-Way / 1 on Pressure
30VM9872
Backordered
POR
F562C2068 bar9/16 inchInstrumentation Products Division3.18 mm14.29 mmVEE30,0002-Way Angle / Replaceable Seat
30VM9882
Backordered
POR
F562C2068 bar9/16 inchInstrumentation Products Division0.125 inch14.29 mmREG30,0002-Way Angle / Replaceable Seat
40VM9071
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division0.109 inch14.29 mmVEE40,0002-Way Straight
40VM9072
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division0.109 inch14.29 mmVEE40,0002-Way Angle
40VM9075
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division2.77 mm14.29 mmVEE40,0003-Way / 2-Stem Manifold
40VM9081
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division2.77 mm14.29 mmREG40,0002-Way Straight
40VM9082
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division2.77 mm14.29 mmREG40,0002-Way Angle
40VM9085
Backordered
POR
F562C402760 bar9/16 inchInstrumentation Products Division0.109 inch14.29 mmREG40,0003-Way / 2-Stem Manifold
60VM4071
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmVEE60,0002-Way Straight
60VM4072
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmVEE60,0002-Way Angle
60VM4073
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmVEE60,0003-Way / 2 on Pressure
60VM4074
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmVEE60,0003-Way / 1 on Pressure
60VM4075
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division0.062 inch6.35 mmVEE60,0003-Way / 2-Stem Manifold
60VM4081
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmREG60,0002-Way Straight
60VM4082
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmREG60,0002-Way Angle
60VM4083
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division0.062 inch6.35 mmREG60,0003-Way / 2 on Pressure
60VM4084
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmREG60,0003-Way / 1 on Pressure
60VM4085
Backordered
POR
F250C4137 bar1/4 inchInstrumentation Products Division1.57 mm6.35 mmREG60,0003-Way / 2-Stem Manifold

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains