• Availability & Price
  • Search SKU
Filter by attributes
  • Ambient Temperature
  • Application
  • Brand
  • Carbon Adsorption Filter Included
  • Connection Type
  • Depth
  • Division
  • Division
  • Filter Included
  • Flow Rate
More Filters...

OFAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

Picture for category OFAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker OFAS Oil Free Air Systems deliver clean, dry, technically oil-free compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality.

Energy efficient heatless dryers with integrated dewpoint energy management systems provide a constant outlet pressure dewpoint of ≤-40°C, (≤-70°C or ≤-20°C optional) at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Many applications specify the need for ‘oil-free’ compressed air. Ambient air drawn into an air compressor contains oil in a vapour phase, which after compression, cools and condenses in the compressed air system to produce liquid oil and aerosols of oil. No matter which type of air compressor is installed (oil lubricated or oil-free), if the application requires ‘oil-free’ compressed air, treatment is required.

The coalescing filters and OVR adsorption filter fitted as standard to Parker OFAS models treat both the oil vapour from the ambient air as well as oil from a lubricated compressor, providing technically oil-free compressed air from both oil-free and oil lubricated compressors.

Using clean, dry, oil-free compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however OFAS Oil Free Air Systems provide the highest levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 5 Stages of purification, treating 8 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• ISO 8573-1 class zero technically oil-free air (total oil ≤0.003mg/m³)
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronisation) and DDS-EST dewpoint dependant switching
• Web server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandTechnologyDivisionDivisionIngress Protection RatingOperating TemperatureNoise LevelAmbient TemperatureDepthWidthHeightWeightIndustryProduct StyleOperating PressureSpecifications MetPower Supply VoltageProduct TypeCarbon Adsorption Filter IncludedApplicationFilter IncludedProduct SeriesConnection TypePort SizeFlow RatePressure Dew PointPump TypeISO Grade
OFASLE120-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm856.0 mm64.8 inch782 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration73 to 190 psigPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-120 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE120-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)355 Kg<br/>(782 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE120-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum21.7 inch856.0 mm1647.0 mm782 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 bargPED 2014/68/EU400.0 VAC (±10%) three-phase, 50Hz (Standard)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-120 (Order Separately)Class 2.1.0
OFASLE120-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)355 Kg<br/>(782 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)Class 2.1.0
OFASLE130-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm40.3 inch1892.0 mm992 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 bargPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"1020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-130 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE130-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)450 Kg<br/>(992 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"1020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-160 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE130-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum550.0 mm40.3 inch1892.0 mm992 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration73 to 190 psigPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-130 (Order Separately)Class 2.1.0
OFASLE130-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)450 Kg<br/>(992 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR400IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX045HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX045HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-170 (Order Separately)Class 2.1.0
OFASLE140-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum21.7 inch1194.0 mm1892.0 mm543 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration73 to 190 psigPED 2014/68/EU400.0 VAC (±10%) three-phase, 50Hz (Standard)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"1275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE140-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)543 Kg<br/>(1197 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"1275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-100 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE140-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA55.0 °C Maximum21.7 inch1194.0 mm74.5 inch543 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 bargPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-140 (Order Separately)Class 2.1.0
OFASLE140-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)543 Kg<br/>(1197 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-110 (Order Separately)Class 2.1.0
OFASLE150-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA131.0 °F Maximum21.7 inch53.6 inch74.5 inch1404 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 bargPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"1530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-150 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE150-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"1530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-120 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE150-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch53.6 inch1892.0 mm637 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration73 to 190 psigPED 2014/68/EU460.0 VAC (±10%) three-phase, 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP2½"1071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)Class 2.1.0
OFASLE150-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1363 mm<br/>(53.6 inch)1892 mm<br/>(74.5 inch)637 Kg<br/>(1404 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR450IGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX050HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX050HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT2½"1071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-130 (Order Separately)Class 2.1.0
OFASLE160-40G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP4441 to 122 °F< 75 dBA55.0 °C Maximum550.0 mm1532.0 mm1892.0 mm1611 lb• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration73 to 190 psigPED 2014/68/EU400.0 VAC (±10%) three-phase, 50Hz (Standard)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR500JGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX055HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX055HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP3"1785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-160 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE160-40N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR500JGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX055HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX055HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT3"1785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionVacuum: HLVAP-OL-02-140 (Order Separately)Class 2.2.0 or Class 2.3.0
OFASLE160-70G13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50 °C< 75 dBA131.0 °F Maximum550.0 mm1532.0 mm1892.0 mm731 kg• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 bargPED 2014/68/EU400.0 VAC (±10%) three-phase, 50Hz (Standard)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR500JGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX055HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX055HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)BSPP3"1250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-160 (Order Separately)Class 2.1.0
OFASLE160-70N13BC
Backordered
POR
PARKERFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP445 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1532 mm<br/>(60.3 inch)1892 mm<br/>(74.5 inch)731 Kg<br/>(1611 lbs)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingVacuum Assisted Heatless Regeneration5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option)Compressed Air Dryer with Oil Vapour Reduction and FiltrationOVR500JGXXCompressed Air Treatment - Clean Dry, Oil-Free AirGeneral Purpose Coalescing Filter<br/>AOPX055HGFX<br/><br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/>General Purpose Dry Particulate Filter<br/>AAPX055HGFXOFAS - Oil Free Air System - Large Flow, Low Energy Heatless (Models OFAS LE 100-170)NPT3"1250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F)-70°C (-100°F)Vacuum: HLVAP-OL-02-150 (Order Separately)Class 2.1.0

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.