• Availability & Price
  • Search SKU
Filter by attributes
  • Compatible Element
  • Connection Type
  • Depth
  • Division
  • Filter Type
  • Height
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Micron Rating
More Filters...

OIL-X IP50 Intermediate Pressure Compressed Air Filter (For Pressures Up To 50 bar g)

Picture for category OIL-X IP50 Intermediate Pressure Compressed Air Filter (For Pressures Up To 50 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The removal of impurities within a compressed air system is vitally important in order to prevent contamination of downstream processes equipment and products. Parker domnick hunter OIL-X IP50 intermediate pressure filters combine the new energy efficient OIL-Xplus filter elements with specially designed housings to provide high efficiency filtration for applications up to 50 bar g (725 psi g).

Available in various filtration grades and connection sizes, they provide a level of protection tailored to your application. Typical Applications: P.E.T. bottling, air blast circuit breakers, shipborne air distribution systems, engine starting and pressure testing of pipelines.

Features
• Coalescing filters fully tested in accordance with ISO12500-1.

• Performance independently validated by Lloyds Register.

• Elimination of oil, water and dirt - Available in six filtration grades.

• 10 years guarantee on filter housing.

• Ease of installation - Compact housing design.

• Port options - BSPP / NPT - Weld Flange kits also available.

Benefits
• Meets or exceeds the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality.

• Ideally suited for Food / Beverage / Pharmaceutical / P.E.T. applications: FDA Title 21 compliance and EC1935 - 2004 Exempt.

• Trouble free, high performance - quality OIL-Xplus element backed with a 1 year performance guarantee.

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceMaximum Flow RateCompatible ElementDepthWidthDivisionMaximum Operating PressureMinimum Operating TemperatureWeightPressure DifferentialMaximum Operating TemperatureHeightConnection TypeFilter TypePort Connection (inch)Micron Rating
AAIP50-010-AGFX
Backordered
POR
64 CFM at 725 psigK009AA2.7 inch78 mmGas Separation and Filtration Division EMEA725 psig35 °F1.3 kg3.0 psi (Wet)212 °F6.9 inchBSPPCoalescing¼Down to 0.01 micron
AAIP50-010-ANFX
Backordered
POR
108 m3/hour at 50 bargK009AA2.7 inch3.1 inchGas Separation and Filtration Division EMEA725 psig35 °F1.3 kg3.0 psi (Wet)100 °C6.9 inchNPTCoalescing¼Down to 0.01 micron
AAIP50-020-BGFX
Backordered
POR
162 m3/hour at 50 bargK009AA68 mm3.1 inchGas Separation and Filtration Division EMEA50 barg35 °F1.3 kg140 mbar (Dry)212 °F175 mmBSPPCoalescing3/8Down to 0.01 micron
AAIP50-020-BNFX
Backordered
POR
95 CFM at 725 psigK009AA68 mm78 mmGas Separation and Filtration Division EMEA50 barg2 °C1.3 kg200 mbar (Wet)212 °F175 mmNPTCoalescing3/8Down to 0.01 micron
AAIP50-030-CGFX
Backordered
POR
201 CFM at 725 psigK030AA3.3 inch3.5 inchGas Separation and Filtration Division EMEA50 barg2 °C2 kg200 mbar (Wet)100 °C245 mmBSPPCoalescing½Down to 0.01 micron
AAIP50-030-CNFX
Backordered
POR
342 m3/hour at 50 bargK030AA3.3 inch89 mmGas Separation and Filtration Division EMEA725 psig2 °C2 kg140 mbar (Dry)100 °C9.6 inchNPTCoalescing½Down to 0.01 micron
AAIP50-040-DGFX
Backordered
POR
522 m3/hour at 50 bargK030AA84 mm3.5 inchGas Separation and Filtration Division EMEA50 barg35 °F4.4 lb140 mbar (Dry)100 °C9.6 inchBSPPCoalescing¾Down to 0.01 micron
AAIP50-040-DNFX
Backordered
POR
307 CFM at 725 psigK030AA3.3 inch3.5 inchGas Separation and Filtration Division EMEA50 barg2 °C4.4 lb140 mbar (Dry)212 °F9.6 inchNPTCoalescing¾Down to 0.01 micron
AAIP50-050-EGFX
Backordered
POR
604 CFM at 725 psigK145AA116 mm4.8 inchGas Separation and Filtration Division EMEA725 psig35 °F11 lb140 mbar (Dry)100 °C16.6 inchBSPPCoalescing1Down to 0.01 micron
AAIP50-050-ENFX
Backordered
POR
604 CFM at 725 psigK145AA4.6 inch122 mmGas Separation and Filtration Division EMEA50 barg35 °F5 kg1.5 psi (Dry)212 °F423 mmNPTCoalescing1Down to 0.01 micron
AAIP50-060-GGFX
Backordered
POR
1674 m3/hour at 50 bargK145AA116 mm122 mmGas Separation and Filtration Division EMEA725 psig2 °C11 lb1.5 psi (Dry)100 °C16.6 inchBSPPCoalescing1½Down to 0.01 micron
AAIP50-060-GNFX
Backordered
POR
985 CFM at 725 psigK145AA116 mm4.8 inchGas Separation and Filtration Division EMEA725 psig35 °F11 lb200 mbar (Wet)212 °F16.6 inchNPTCoalescing1½Down to 0.01 micron
AAIP50-070-HGFX
Backordered
POR
3473 m3/hour at 50 bargK220AA162 mm170 mmGas Separation and Filtration Division EMEA50 barg2 °C10 kg1.5 psi (Dry)100 °C480 mmBSPPCoalescing2Down to 0.01 micron
AAIP50-070-HNFX
Backordered
POR
3473 m3/hour at 50 bargK220AA162 mm6.7 inchGas Separation and Filtration Division EMEA725 psig35 °F10 kg140 mbar (Dry)100 °C18.9 inchNPTCoalescing2Down to 0.01 micron
AARIP50-070-HGMX
Backordered
POR
3473 m3/hour at 50 bargK220ARR162 mm170 mmGas Separation and Filtration Division EMEA50 barg2 °C22 lb1.5 psi (Dry)212 °F480 mmBSPPDry Particulate2Down to 0.01 micron
ACSIP50-010-AGMX
Backordered
POR
64 CFM at 725 psigK009ACS6.4 inch6.7 inchGas Separation and Filtration Division EMEA725 psig35 °F10 kg100 mbar (Dry)86 °F18.9 inchBSPPOil Vapour Removal¼n/a
ACSIP50-020-BGMX
Backordered
POR
95 CFM at 725 psigK009ACS162 mm170 mmGas Separation and Filtration Division EMEA50 barg2 °C10 kg1.5 psi (Dry)30 °C18.9 inchBSPPOil Vapour Removal3/8n/a
ACSIP50-030-CGMX
Backordered
POR
201 CFM at 725 psigK030ACS162 mm170 mmGas Separation and Filtration Division EMEA50 barg2 °C22 lb1.5 psi (Dry)30 °C18.9 inchBSPPOil Vapour Removal½n/a
ACSIP50-040-DGMX
Backordered
POR
522 m3/hour at 50 bargK030ACS6.4 inch170 mmGas Separation and Filtration Division EMEA725 psig2 °C10 kg1.5 psi (Dry)86 °F18.9 inchBSPPOil Vapour Removal¾n/a
ACSIP50-050-EGMX
Backordered
POR
1026 m3/hour at 50 bargK145ACS162 mm6.7 inchGas Separation and Filtration Division EMEA725 psig35 °F10 kg1.5 psi (Dry)86 °F18.9 inchBSPPOil Vapour Removal1n/a

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains