OIL-X OVR Oil Vapour Reduction Filter

Picture for category OIL-X OVR Oil Vapour Reduction Filter

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

OIL-X OVR Oil Vapour Reduction filters are designed to reduce oil vapour and also overcome the issues of traditional loose filled carbon towers. The loose filled beds of carbon towers offer reduced contact time due to unrestricted air channelling, meaning they are prone to movement of the carbon adsorbent during operation; resulting in degrading performance, attrition of the adsorbent material, high particulate generation and blockage of downstream filters.

Manufactured from extruded aluminium, the Parker OIL-X OVR is smaller and lighter than equivalent carbon towers. Compact activated carbon cartridges utilise a unique filling technique to maximise packing density of the adsorbent bed. Retained to prevent movement, 100% of the activated carbon bed is then utilised during operation, guaranteeing performance, whilst the heavy attrition, dusting and blocked particulate filters associated with carbon tower designs is eliminated. The use of cartridges also provides trouble free maintenance, reducing system downtime.

Oil free plant air can be affected by many factors such as pressure, temperature, air flow, oil concentration and humidity. The OIL-X OVR selection process considers all of these factors to ensure consistent outlet air quality over 12 months of continuous operation.

Features
• Suitable for use with oil lubricated and oil-free compressors

• Tested in accordance with ISO8573-5 and 3rd party performance validated by Lloyds Register

• Can be installed in the compressor room for plant scale protection, at point of use to protect critical applications (or both if old, contaminated piping is in use)

• FDA Title 21 compliant & EC1935 exempt

• Unique adsorbent fill technique

• Large capacity bed reduces the number of units required but still offers a compact and light weight design with flexible inlet / outlet connectivity

• Simple, easy maintenance

Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

Please note: The lifetime of the activated carbon filling can vary and is dependent on the contamination type and quantity and also on the humidity of the compressed air.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceProduct TypeDrainDivisionDivisionWidthProduct SeriesCompatible ElementSpecifications MetOperating PressureFilter TypeResidual Oil ContentDepthMicron RatingHeightBrandWeightOperating TemperatureElement Change IntervalTechnologyApplicationPressure DifferentialIndustryMaximum Flow RateConnection TypePort Size
OVRP300HGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA350.0 mmOIL-X OVRP300OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II.15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.534.0 mmn/a39.3 inchPARKER38 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1 psi Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental289 m³/h @ 7 barg (170 cfm @ 102 psig)BSPP2 inch
OVRP300HNXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA350.0 mmOIL-X OVRP300OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.21 inchn/a39.3 inchPARKER84 lb2 to 50 °C12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental289 m³/h @ 7 barg (170 cfm @ 102 psig)NPT2 inch
OVRP350HGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP350OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.21.2 inchn/a1062.0 mmPARKER67 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1 psi Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental586 m³/h @ 7 barg (345 cfm @ 102 psig)BSPP2 inch
OVRP350HNXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP350OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.21.2 inchn/a41.8 inchPARKER147 lb2 to 50 °C12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental587 m³/h @ 7 barg (345 cfm @ 102 psig)NPT2 inch
OVRP400IGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA550.0 mmOIL-X OVRP400OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II1 to 16 bargAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.682.0 mmn/a41.8 inchPARKER93 kg2 to 50 °C12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications350.0 mbar Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1172 m³/h @ 7 barg (690 cfm @ 102 psig)BSPP2 inch
OVRP400INXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP400OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II1 to 16 bargAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.682.0 mmn/a41.8 inchPARKER205 lb35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications350.0Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1172 m³/h @ 7 barg (690 cfm @ 102 psig)NPT2 inch
OVRP450IGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA550.0 mmOIL-X OVRP450OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.836.0 mmn/a41.8 inchPARKER121 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications350.0 mbar Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1758 m³/h @ 7 barg (1035 cfm @ 102 psig)BSPP2½ inch
OVRP450INXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA550.0 mmOIL-X OVRP450OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.32.9 inchn/a1062.0 mmPARKER121 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1758 m³/h @ 7 barg (1035 cfm @ 102 psig)NPT2½ inch
OVRP500IGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP500OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II1 to 16 bargAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.39.6 inchn/a1062.0 mmPARKER318 lb2 to 50 °C12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1 psi Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental2345 m³/h @ 7 barg (1380 cfm @ 102 psig)BSPP2½ inch
OVRP500INXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA550.0 mmOIL-X OVRP500OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II15 to 232 psigAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.39.6 inchn/a41.8 inchPARKER144 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications5.1Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental2345 m³/h @ 7 barg (1380 cfm @ 102 psig)NPT2½ inch
OVRP550IGXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP550OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II1 to 16 bargAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.46.2 inchn/a1062.0 mmPARKER377 lb2 to 50 °C12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications350.0 mbar Initial Dry, 100% FlowIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1172 m³/h @ 7 barg (690 cfm @ 102 psig)BSPP2½ inch
OVRP550INXX
Backordered
POR
Compressed Air FilterNot ApplicableGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA21.7 inchOIL-X OVRP550OVRFully tested - In accordance with ISO8573-5<br/>Filtration performance independently validated - by Lloyds Register. <br/> <br/>PED 2014/68/EU Fluid Group II1 to 16 bargAdsorption:<br/>Oil Vapour Reduction≤0.003 mg/m³ / ≤0.003 ppm(w) at system operating temperature and when corrected to match system conditions.1174.0 mmn/a41.8 inchPARKER171 kg35 to 122 °F12 months when sized to correct operating temperature and system conditions.FiltrationCompressed Air and Nitrogen Gas Applications350.0Industrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & Dental1172 m³/h @ 7 barg (690 cfm @ 102 psig)NPT2½ inch

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains