• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Coil Specifications Met
  • Coil Type
  • Coil Type
  • Division
  • Flow Coefficient 1
  • Flow Coefficient 2
  • Flow Factor 1 (Cv)
  • Function
More Filters...

Parker 2-Way Normally Closed, 1" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Closed, 1" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Closed 1" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids and gases. These valves are available in brass construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionSeal MaterialBody MaterialPort SizeDivisionPort TypeMediaValve TypeInput VoltageOrifice 2 SizeNumber of PortsFlow Coefficient 2Coil Specifications MetMinimum Fluid TemperatureMinimum Pressure DifferentialActuation TypePower ConsumptionProduct SeriesCoil TypeOrifice 1 SizeFlow Coefficient 1Maximum Fluid TemperatureMaximum Pressure DifferentialSeal MaterialVoltage (V)Power (Watts)Coil TypeFlow Factor 1 (Cv)
7221GBN64E00N0C111P3
Backordered
POR
Normally Closed (NC)EPDMBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60n/a2n/aNEMA 4X0 °F0 psiDirect Lift10 W (AC)7000 Series1/2" NPT Conduit, 18" Leads1 inch12.5 Cv210 °F230 psi (AC)EPDM110/50-120/6010 Watt (AC)1/2" NPT Conduit, 18" Leads12.5
7221GBN64E00N0C322C1
Backordered
POR
Normally Closed (NC)EPDMBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way12.0 VDCn/a2n/aNEMA 4X0 °F0 psiDirect Lift22 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11.7 Cv210 °F85 psi (DC)EPDM12 VDC22 Watt (DC)1/2" NPT Conduit, 18" Leads11.7
7221GBN64E00N0C322C2
Backordered
POR
Normally Closed (NC)EPDMBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way24.0 VDCn/a2n/aNEMA 4X0 °F0 psiDirect Lift22 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch12.5 Cv210 °F85 psi (DC)EPDM24 VDC22 Watt (DC)1/2" NPT Conduit, 18" Leads12.5
7221GBN64E00N0D100P3
Backordered
POR
Normally Closed (NC)EPDMBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60n/a2n/aNEMA 4X0 °F0 psiDirect Lift10 W (AC)7000 SeriesDIN Form A1 inch11.7 Cv210 °F230 psi (AC)EPDM110/50-120/6010 Watt (AC)DIN Form A11.7
7221GBN64N00N0C111Q3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way220/50 to 240/60n/a2n/aNEMA 4X0 °F0 psiDirect Lift10 W (AC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11.7 Cv185 °F230 psi (AC)NBR220/50-240/6010 Watt (AC)1/2" NPT Conduit, 18" Leads11.7
7221GBN64N00N0C322C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 4X0 °F0 psiDirect Lift22 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11.7 Cv185 °F85 psi (DC)NBR24 VDC22 Watt (DC)1/2" NPT Conduit, 18" Leads11.7
7221GBN64N00N0H111P3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60n/a2n/aNEMA 90 °F0 psiDirect Lift10 W (AC)7000 SeriesHazardous Location Coil1 inch2.5 Cv185 °F230 psi (AC)NBR110/50-120/6010 Watt (AC)Hazardous Location Coil2.5
7221GBN64V00N0H222Q3
Backordered
POR
Normally Closed (NC)FKMBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way220/50 to 240/60n/a2n/aNEMA 70 °F0 psiDirect Lift10 W (AC)7000 SeriesHazardous Location Coil1 inch12.5 Cv185 °F230 psi (AC)FKM220/50-240/6010 Watt (AC)Hazardous Location Coil12.5
73212BN63N00N0C111Q3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way220/50 to 240/60n/a2n/aNEMA 4X0 °F5 psiPilot10 W (AC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11 Cv185 °F300 psi (AC)NBR220/50-240/6010 Watt (AC)1/2" NPT Conduit, 18" Leads11
73212BN63N00N0D100P3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60n/a2n/aNEMA 4X0 °F5 psiPilot10 W (AC)7000 SeriesDIN Form A1 inch11 Cv185 °F300 psi (AC)NBR110/50-120/6010 Watt (AC)DIN Form A11
73212BN63N00N0H111C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 90 °F5 psiPilot10 W (DC)7000 SeriesHazardous Location Coil1 inch5 Cv185 °F300 psi (DC)NBR24 VDC10 Watt (DC)Hazardous Location Coil5
73212BN63N00N0H111P3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60n/a2n/aNEMA 90 °F5 psiPilot10 W (AC)7000 SeriesHazardous Location Coil1 inch13.5 Cv185 °F300 psi (AC)NBR110/50-120/6010 Watt (AC)Hazardous Location Coil13.5
73218BN64N00N0C111C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 4X0 °F5 psiPilot10 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch13.5 Cv185 °F125 psi (DC)NBR24 VDC10 Watt (DC)1/2" NPT Conduit, 18" Leads13.5
73218BN64N00N0D100C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 4X0 °F5 psiPilot10 W (DC)7000 SeriesDIN Form A1 inch13.5 Cv185 °F125 psi (DC)NBR24 VDC10 Watt (DC)DIN Form A13.5
73218BN64N00N0H111C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 70 °F5 psiPilot10 W (DC)7000 SeriesHazardous Location Coil1 inch5.5 Cv185 °F125 psi (DC)NBR24 VDC10 Watt (DC)Hazardous Location Coil5.5
7321GBN64N00N0C111C1
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way12.0 VDCn/a2n/aNEMA 4X0 °F5 psiPilot10 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11.7 Cv185 °F230 psi (DC)NBR12 VDC10 Watt (DC)1/2" NPT Conduit, 18" Leads11.7
7321GBN64N00N0C111C2
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCn/a2n/aNEMA 4X0 °F5 psiPilot10 W (DC)7000 Series1/2" NPT Conduit, 18" Leads1 inch11.7 Cv185 °F230 psi (DC)NBR24 VDC10 Watt (DC)1/2" NPT Conduit, 18" Leads11.7
7321GBN64N00N0C111P3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60n/a2n/aNEMA 4X0 °F5 psiPilot10 W (AC)7000 Series1/2" NPT Conduit, 18" Leads1 inch12.5 Cv185 °F230 psi (AC)NBR110/50-120/6010 Watt (AC)1/2" NPT Conduit, 18" Leads12.5
7321GBN64N00N0D100P3
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60n/a2n/aNEMA 4X0 °F0 psiPilot10 W (AC)7000 SeriesDIN Form A1 inch11.7 Cv185 °F230 psi (AC)NBR110/50-120/6010 Watt (AC)DIN Form A11.7
7321GBN64N00N0H111C1
Backordered
POR
Normally Closed (NC)NBRBRASS1 inchFluid Control DivisionNPTGeneral Purpose for Air2-Way12.0 VDCn/a2n/aNEMA 70 °F5 psiPilot10 W (DC)7000 SeriesHazardous Location Coil1 inch11.7 Cv185 °F230 psi (DC)NBR12 VDC10 Watt (DC)Hazardous Location Coil11.7

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains