Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Closed 3/8" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionSeal MaterialDivisionPort TypeMediaValve TypeInput VoltageActuation TypeOrifice 2 SizeNumber of PortsFlow Coefficient 2Coil Specifications MetMinimum Fluid TemperatureMinimum Pressure DifferentialPort SizeMaximum Fluid TemperatureCoil TypeBody MaterialOrifice 1 SizeProduct SeriesPower ConsumptionFlow Coefficient 1Maximum Pressure DifferentialSeal MaterialVoltage (V)Coil TypePower (Watts)Body MaterialFlow Factor 1 (Cv)Orifice 1 Size (inch)Maximum Pressure Differential (psi)
71215SN33N00N0C322P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Actingn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 4XStainless Steel 430 F7/16 inch7000 Series22 W (AC)2 Cv25 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class H, NEMA 4X22 Watt (AC)430F Stainless27/1625 psi (AC)
71215SN33NHPN0C111P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Actingn/a2n/aNEMA 4X0 °F5 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XStainless Steel 430 F7/16 inch7000 Series10 W (AC)2 Cv11 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (AC)430F Stainless27/1611 psi (AC)
71215SN33NHPN0H111P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60Direct Actingn/a2n/aNEMA 90 °F5 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9Stainless Steel 430 F7/16 inch7000 Series10 W (AC)2 Cv11 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 910 Watt (AC)430F Stainless27/1611 psi (AC)
7121KBN3UV00N0C111P3
Backordered
POR
Normally Closed (NC)FKMFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Actingn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XBRASS7/16 inch7000 Series10 W (AC)0.83 Cv55 psi (AC)FKM110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (AC)BRASS0.837/1655 psi (AC)
7121KBN3UV00N0C222C1
Backordered
POR
Normally Closed (NC)FKMFluid Control DivisionNPTGeneral Purpose for Air2-Way12.0 VDCDirect Actingn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 4XBRASS7/16 inch7000 Series10 W (DC)0.83 Cv20 psi (DC)FKM12 VDC1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X10 Watt (DC)BRASS0.837/1620 psi (DC)
7121KBN3UV00N0D100C2
Backordered
POR
Normally Closed (NC)FKMFluid Control DivisionNPTGeneral Purpose for Air2-Way24.0 VDCDirect Actingn/a2n/aClass F0 °F0 psi3/8 inch185 °FDIN Form A, Class FBRASS7/16 inch7000 Series10 W (DC)0.83 Cv20 psi (DC)FKM24 VDCDIN Form A, Class F10 Watt (DC)BRASS0.837/1620 psi (DC)
7121KBN3UV00N0D100P3
Backordered
POR
Normally Closed (NC)FKMFluid Control DivisionNPTLiquids and Gases2-Way110/50-120/60Direct Actingn/a2n/aClass F0 °F0 psi3/8 inch185 °FDIN Form A, Class FBRASS7/16 inch7000 Series10 W (AC)0.83 Cv55 psi (AC)FKM110/50-120/60DIN Form A, Class F10 Watt (AC)BRASS0.837/1655 psi (AC)
72218BN3TN00N0C111P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Liftn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XBRASS7/16 inch7000 Series10 W (AC)3 Cv100 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (AC)BRASS37/16100 psi (AC)
72218BN3TN00N0D300C2
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCDirect Liftn/a2n/aClass H0 °F0 psi3/8 inch185 °FDIN Form A, Class HBRASS7/16 inch7000 Series22 W (DC)3 Cv40 psi (DC)NBR24 VDCDIN Form A, Class H22 Watt (DC)BRASS37/1640 psi (DC)
72218BN3TN00N0H222P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Liftn/a2n/aNEMA 70 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASS7/16 inch7000 Series10 W (AC)3 Cv100 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 910 Watt (AC)BRASS37/16100 psi (AC)
72218BN3TN00N0H222Q3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way220/50 to 240/60Direct Liftn/a2n/aNEMA 90 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASS7/16 inch7000 Series10 W (AC)3 Cv100 psi (AC)NBR220/50-240/601/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 910 Watt (AC)BRASS37/16100 psi (AC)
7221GBN3VN00N0C111P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Liftn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XBRASS7/16 inch7000 Series10 W (AC)4.4 Cv230 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (AC)BRASS4.47/16230 psi (AC)
7221GBN3VN00N0C111Q3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way220/50 to 240/60Direct Liftn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XBRASS7/16 inch7000 Series10 W (AC)4.4 Cv230 psi (AC)NBR220/50-240/601/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (AC)BRASS4.47/16230 psi (AC)
7221GBN3VN00N0C322C2
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCDirect Liftn/a2n/aNEMA 4X0 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 4XBRASS7/16 inch7000 Series22 W (DC)4.4 Cv100 psi (DC)NBR24 VDC1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X22 Watt (DC)BRASS4.47/16100 psi (DC)
7221GBN3VN00N0D100P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Liftn/a2n/aClass F0 °F0 psi3/8 inch185 °FDIN Form A, Class FBRASS7/16 inch7000 Series10 W (AC)4.4 Cv230 psi (AC)NBR110/50-120/60DIN Form A, Class F10 Watt (AC)BRASS4.47/16230 psi (AC)
7221GBN3VN00N0D300C2
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way24.0 VDCDirect Liftn/a2n/aClass H0 °F0 psi3/8 inch185 °FDIN Form A, Class HBRASS7/16 inch7000 Series22 W (DC)4.4 Cv100 psi (DC)NBR24 VDCDIN Form A, Class H22 Watt (DC)BRASS4.47/16100 psi (DC)
7221GBN3VN00N0H111P3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way110/50-120/60Direct Liftn/a2n/aNEMA 70 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9BRASS7/16 inch7000 Series10 W (AC)4.4 Cv230 psi (AC)NBR110/50-120/601/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 910 Watt (AC)BRASS4.47/16230 psi (AC)
7221GBN3VN00N0H111Q3
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTGeneral Purpose for Air2-Way220/50 to 240/60Direct Liftn/a2n/aNEMA 90 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9BRASS7/16 inch7000 Series10 W (AC)4.4 Cv230 psi (AC)NBR220/50-240/601/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 910 Watt (AC)BRASS4.47/16230 psi (AC)
7221GBN3VN00N0H322C2
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTLiquids and Gases2-Way24.0 VDCDirect Liftn/a2n/aNEMA 90 °F0 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 9BRASS7/16 inch7000 Series22 W (DC)4.4 Cv100 psi (DC)NBR24 VDC1/2" NPT Conduit, 18" Leads, Class H, NEMA 7, 922 Watt (DC)BRASS4.47/16100 psi (DC)
73212BN3SN00N0C111C1
Backordered
POR
Normally Closed (NC)NBRFluid Control DivisionNPTLiquids and Gases2-Way12.0 VDCManualn/a2n/aNEMA 4X0 °F5 psi3/8 inch185 °F1/2" NPT Conduit, 18" Leads, Class F, NEMA 4XBRASS7/16 inch7000 Series10 W (DC)2.4 Cv300 psi (DC)NBR12 VDC1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X10 Watt (DC)BRASS2.47/16300 psi (DC)

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains