Parker's robust and durable pilot operated directional control valves series D31DW, D31NW, D*1VW are almost universally applicable and ensure a reliable operation. A wide variety of spools and options allows to design an unlimited number of hydraulic circuits.

The pilot operated directional control valves are available in 4 sizes: D31DW (standard) and D31NW (high flow) in NG10/NFPA D05, D41VW in NG16/NFPA D07, D91VW (for port diameter up to 32 mm) in NG25/NFPA D08 and D111VW in NG32/NFPA D10.

All sizes are optionally available with position control or as explosion-proof version according to ATEX and IECEx.

Markets:
• Industrial

Features/Benefits:
• Proven robust design that represents our long-term experience in hydraulics
• Wide range of spools - suitable for almost all hydraulic circuits
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Short delivery time – no warehousing necessary
• Optionally with position control
• Optionally without manual override
• Optionally as explosion-proof version

Applications:
• Suitable for general hydraulic applications

Explosion-proof versions
The valves are not only ATEX certified (explosion proof class is Ex e mb II T4 Gb for use in zone 1 and 2) but also equipped with IECEx compliant solenoids which are  certified  in  accordance with IECEx standard for equipment class 2 G. All explosion-proof solenoids are DC design. The valves for AC operate with integrated rectifier.

Note:
The minimum pilot pressure must be ensured for all operating conditions of the directional valve. Additionally spools with a P to T connection in the deenergized  position  need  an  external  pressure  supply (external inlet) or an integral check valve.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceFunctionActuation TypeDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialOperation TypeFor Fluid TypeBody MaterialWeightProduct SeriesConnection TypeMaximum Flow RateSeal MaterialPort ConnectionMarkingInput VoltagePilot Inlet / Drain LocationsSpool CodeSpool PositionSolenoid OptionAdditional OptionsBore DiameterMaximum Flow Rate
D31NW004C4NJWI3N
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCInternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsPosition control, end position monitored, side A and B11 mm170 L/min
D31NW004C4NJWTI6N
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCInternal/internal0043 positions, spring offset in position 0, operated in position a or bWithout manual overridePosition control, start position monitored, side A and B11 mm170 L/min
D31NW004C4NNEE3B
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveExplosion Proof with Cable Glands170 L/minNBRNG10 / CETOP 05Standard230 VAC, 50 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bExplosion proof solenoids Ex e mb II T4Gb + IECEx conformityPilot choke, meter-in11 mm170 L/min
D31NW004C4NPEE
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveExplosion Proof with Cable Glands170 L/minNBRNG10 / CETOP 05Standard110 VAC, 50 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bExplosion proof solenoids Ex e mb II T4Gb + IECEx conformityStandard11 mm170 L/min
D31NW004C4NTW
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard230/240 VAC, 50/60 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW004C4NTW3B
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard230/240 VAC, 50/60 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsPilot choke, meter-in11 mm170 L/min
D31NW004C4NYW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard110/120 VAC, 50/60 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW004C4VJW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateFPMPilotWater-GlycolCast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minFPMNG10 / CETOP 05Standard24 VDCInternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW004C4VNEE
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotWater-GlycolCast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minFPMNG10 / CETOP 05Standard230 VAC, 50 HzInternal/internal0043 positions, spring offset in position 0, operated in position a or bExplosion proof solenoids Ex e mb II T4Gb + IECEx conformityStandard11 mm170 L/min
D31NW004C5NJW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCExternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW004C5NJW1T
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCExternal/internal0043 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsMeter-in + pressure reducing valve11 mm170 L/min
D31NW004K2NYW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron7.6 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard110/120 VAC, 50/60 HzExternal/external0042 positions, spring offset in position 0, operated in position bStandard solenoid without optionsNA11 mm170 L/min
D31NW004K4NJEE
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron7.6 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCInternal/internal0042 positions, spring offset in position 0, operated in position bExplosion proof solenoids Ex e mb II T4Gb + IECEx conformityStandard11 mm170 L/min
D31NW004K4NJW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron7.6 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCInternal/internal0042 positions, spring offset in position 0, operated in position bStandard solenoid without optionsNA11 mm170 L/min
D31NW009C2NJW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCExternal/external0093 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW009C3NJW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCIntegral check valve/external0093 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW009C3NTW
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard230/240 VAC, 50/60 HzIntegral check valve/external0093 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min
D31NW009C3NYW3A
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard110/120 VAC, 50/60 HzIntegral check valve/external0093 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsPilot choke, meter-out11 mm170 L/min
D31NW009C5NJWTI6N
Backordered
POR
3-WaySolenoidIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard24 VDCExternal/internal0093 positions, spring offset in position 0, operated in position a or bWithout manual overridePosition control, start position monitored, side A and B11 mm170 L/min
D31NW009C5NYW
Backordered
POR
3-WaySolenoid60 °C-25 °C350 barSubplateNBRPilotHydraulic Oil According to DIN 51524Cast Iron8.1 kgDirectional Control ValveConnector as per EN 175301-803170 L/minNBRNG10 / CETOP 05Standard110/120 VAC, 50/60 HzExternal/internal0093 positions, spring offset in position 0, operated in position a or bStandard solenoid without optionsNA11 mm170 L/min