Pilot Operated Pressure Reducing Valve, Subplate Mounting - Series R4R / R4R*P2 - R4R10-59512B1

Parker subplate mounted pilot operated pressure reducing valves series R4R ensure a constant pressure in the secondary part of the hydraulic system. Series R4R*P2 enables a continuous adjustment by the proportional solenoid operated pilot stage.
Availability: Backordered
SKU: R4R10-59512B1
POR
Products specifications
Attribute nameAttribute value
Flow Rate500 L/minMaximum Operating Temperature60 °C
Product SeriesPressure ValveMaximum Operating PressurePorts A, B and X 350, port Y depressurized bar
Maximum Pressure Setting350 barActuation TypeManually
Seal MaterialNBRBody MaterialCast Iron
Maximum Flow Raten/aMounting TypeSubplate mounting
Weight6 kgDivisionIndustrial Systems Division Europe
Operation TypePilotMinimum Operating Temperature-20 °C
Input VoltageN/AMaximum Operating PressurePort A, B, X 350 bar; port Y depressurized
Pressure Adjustment Control TypeHand knobPressure Control Range350 bar
Seal MaterialNBRPilot Inlet / Drain LocationsInternal, drain external from Y1
Port ConnectionNG32 / CETOP 10