• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Application
  • Body Material
  • Brand
  • Division
  • Division
  • Electrical Connection
  • Electronics Type
  • Filter Efficiency Rating
  • Flow Rate
More Filters...

Pilot Operated Proportional Directional Control Valve - Series D30FP

Picture for category Pilot Operated Proportional Directional Control Valve - Series D30FP

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's series of pilot operated control valves D30FP enables higher product quality and shorter cycle times due to its outstanding dynamics. The high-precision control valve with VCD technology closes the gap between the direct operated D3FP valve and the conventional pilot operated D31FP valve. It provides high flow capacity and practically no flow limits like the D31FP in the envelope size of the D3FP. The valve works with the hydraulic follower principle, with a moving sleeve as main spool.

Version with EtherCAT interface
The DFplus valve series D30FP with EtherCAT (NG10) interface fulfills the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics of the DFplus valves can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Compact design due to hydraulic follower principle - reduces valve footprint, for easier integration
• Exceptional dynamic performance from Parker's VCD technology - optimized cycle times for continuous high productivity
• Very good repeatability - improved process and product accuracy
• Robust valve design - minimized failure
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no warehousing necessary
• Defined spool positioning at power-down - optional P-A / B-T or P-B / A-T or center position (for overlapped spools)
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• With EtherCAT interface upon request - high data speeds, short cycle times

Applications:
• Injection molding
• Machine tools

Technical specification EtherCAT version
The valve is actuated and monitored by the EtherCAT interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionDivisionMaximum Operating PressureMounting TypeSeal MaterialOperation TypeTechnologyBody MaterialMediaApplicationMinimum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMaximum Flow RateFlow RateWeightFilter Efficiency RatingFor Fluid TypeMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureElectronics TypeIngress Protection RatingMounting StyleActuation TypePower Supply VoltageVibration ResistancePort ConnectionPressure DifferentialLeak RateHysteresisResponse TimeMounting PositionSeal MaterialMarkingPilot Inlet / Drain LocationsSpool CodeSpool PositionSolenoid ConnectionElectrical Connection
D30FPE01UC1NB73
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorSurge Free V % Eff.15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / externalE01UCenter position at power down6 + PE + enable±10 V
D30FPE01UC1NE03
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuatorSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / externalE01UCenter position at power down6 + PE-20 - 0 - 20 mA
D30FPE01UC1NS03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529CETOP RP121VCD®-actuator24 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / externalE01UCenter position at power down6 + PE4 - 20 mA
D30FPE01UC4NB03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorRipple < 5 V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE01UCenter position at power down6 + PE±10 V
D30FPE01UC4NB73
Backordered
$9,088.20
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529DIN 24340VCD®-actuator24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE01UCenter position at power down6 + PE + enable±10 V
D30FPE01UC4NE73
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorSurge Free V % Eff.15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE01UCenter position at power down6 + PE + enable-20 - 0 - 20 mA
D30FPE01UC4NS03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529DIN 24340VCD®-actuator24 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE01UCenter position at power down6 + PE4 - 20 mA
D30FPE01UC4VB53
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-20 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529DIN 24340VCD®-actuator24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)FPMStandardInternal / internalE01UCenter position at power down11 + PE±10 V
D30FPE02UC1NB73
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuatorElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / externalE02UCenter position at power down6 + PE + enable±10 V
D30FPE02UC1NS03
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529CETOP RP121VCD®-actuatorRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / externalE02UCenter position at power down6 + PE4 - 20 mA
D30FPE02UC4HB73
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateFor HFC FluidPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-20 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Water-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529CETOP RP121VCD®-actuator24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)for HFC fluidStandardInternal / internalE02UCenter position at power down6 + PE + enable±10 V
D30FPE02UC4NB03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529CETOP RP121VCD®-actuatorRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down6 + PE±10 V
D30FPE02UC4NB73
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down6 + PE + enable±10 V
D30FPE02UC4NE03
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down6 + PE-20 - 0 - 20 mA
D30FPE02UC4NS03
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorRipple < 5 V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down6 + PE4 - 20 mA
D30FPE02UC4NS53
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuatorSurge Free V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down11 + PE4 - 20 mA
D30FPE02UC4NS73
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-25 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuatorRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)NBRStandardInternal / internalE02UCenter position at power down6 + PE + enable4 - 20 mA
D30FPE02UC4VB03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-20 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Other Fluids20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuatorRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)FPMStandardInternal / internalE02UCenter position at power down6 + PE±10 V
D30FPE02UC4VS03
Backordered
POR
PARKER3-WayIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-20 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Hydraulic Oil20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529ISO 4401VCD®-actuatorElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27NG10 / CETOP 055 bar<1000 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)FPMStandardInternal / internalE02UCenter position at power down6 + PE4 - 20 mA
D30FPE50UA1HS03
Backordered
POR
PARKERProportionalIndustrial Systems Division Europe350 barSubplateFor HFC FluidPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic-20 °C60 °C400 cSt-20 °C250 L/min80 L/min6.5 kgISO 4406 18/16/13Water-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboardIP65 in accordance with EN 60529NFPAVCD®-actuator24 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64NG10 / CETOP 055 bar<1800 ml/min< 0.05 %< 7 msPreferably Horizontal (other mounting positions after consultation)for HFC fluidStandardInternal / externalE50UP-A at power down6 + PE4 - 20 mA

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains