• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Application
  • Body Material
  • Brand
  • Connection Type
  • Division
  • Division
  • Electronics Type
  • Filter Efficiency Rating
  • Flow Direction
More Filters...

Pilot Operated Proportional Directional Control Valve - Series D31FB OBE / D41FB OBE / D91FB OBE / D111FB OBE

Picture for category Pilot Operated Proportional Directional Control Valve - Series D31FB OBE / D41FB OBE / D91FB OBE / D111FB OBE

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Representing Parker's extensive experience in industrial hydraulics, the pilot operated proportional DC valves series D*1FB with onboard electronics (OBE) is universally applicable and feature progressive flow characteristics for sensitive flow rate adjustment. The standard performance valves have proven very successful in numerous applications all over the world. Series D*1FB OBE is characterized by a solid design which ensures a long lifetime. It offers an excellent price-performance ratio and best conditions for an economic, reliable operation.

The pilot operated proportional directional control valves D*1FB OBE are available in 4 sizes:
D31FB OBE - NG10 (CETOP 05)
D41FB OBE - NG16 (CETOP 07)
D91FB OBE - NG25 (CETOP 08)
D111FB OBE - NG32 (CETOP 10)

Markets:
• Industrial
• Machine tools
• Rubber & tire processing

Features/Benefits:
• Proven design - ensures reliable operation
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• High flow capacity - optimum efficiency in relation to valve size
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• Energy saving A-regeneration optional
• Switchable hybrid version optional

Applications:
• Machine tool
• General presses
• Tire presses

Technical specifications
The pilot operated proportional directional control valves series D*1FB OBE work with barometric feedback of the main stage to the pressure reducing pilot valve. The pilot control pressure of 25 bar allows high flow rates at maximum stability.

The digital onboard  electronics  is  situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS232 interface is available as accessory. The valve parameters can be edited with the common ProPxD software.

The innovative integrated regenerative function into the A-line (optional) allows energy saving circuits for differential cylinders. The hybrid version can be switched between regenerative mode and standard mode at any time.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionActuation TypeMaximum Flow RateDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialOperation TypeTechnologyBody MaterialMounting PositionMediaApplicationMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureFor Fluid TypeMinimum Kinematic ViscosityFilter Efficiency RatingValve TypeDivisionProduct SeriesMaximum Fluid TemperatureMinimum Fluid TemperatureMounting StyleHysteresisElectronics TypePower Supply VoltageVibration ResistanceMaximum Pilot PressureMinimum Pilot PressureIngress Protection RatingVariation of Opening PointWeightFlow RateLeak RateResponse TimeSeal MaterialPort ConnectionFlow RateSpool PositionPilot Inlet / Drain LocationsSignal InputValve OptionFlow DirectionConnection TypeSpool Code
D31FBE02EC2NS00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bExternal / external4 - 20 mAStandard12 - 20 mA = P-A6 + PEE02
D31FBE02EC4NF00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PEE02
D31FBE02EC4NG00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±20 mAStandard0 - +20 mA = P-B6 + PEE02
D31FBE02EC4NM00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-A6 + PEE02
D31FBE02EC4NS00
Backordered
$4,898.45
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal4 - 20 mAStandard12 - 20 mA = P-A6 + PEE02
D31FBE02EC4NW50
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 V / 4 - 20 mAStandard0 - +10 V = P-A; 12 - 20 mA = P-A11 + PEE02
D31FBE02EC4VF00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-20.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msFPMNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PEE02
D31FBE02EC4VF08
Backordered
POR
PARKER3-WayProportionaln/aHydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-20.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msFPMNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VMonitor switch0 - +10 V = P-B6 + PEE02
D31FBE02EC4VS00
Backordered
POR
PARKER3-WaySolenoidn/aHydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-20.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msFPMNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal4 - 20 mAStandard12 - 20 mA = P-A6 + PEE02
D31FBE02EC4VW50
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-20.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msFPMNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 V / 4 - 20 mAStandard0 - +10 V = P-A; 12 - 20 mA = P-A11 + PEE02
D31FBE02EC5NF00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bExternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PEE02
D31FBE02EC5NG00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bExternal / internal0 - ±20 mAStandard0 - +20 mA = P-B6 + PEE02
D31FBE02EC5VF00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateFPMPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-20.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msFPMNG10 / CETOP 05120 L/MINOperated in position a or bExternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PEE02
D31FBR31EC4NF00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PER31
D31FBR31EC4NM00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-A6 + PER31
D31FBR31EC4NS00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal4 - 20 mAStandard12 - 20 mA = P-A6 + PER31
D31FBR31EC5NF00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bExternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PER31
D31FBR32EC4NF00
Backordered
POR
PARKER3-WaySolenoidn/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal0 - ±10 VStandard0 - +10 V = P-B6 + PER32
D31FBR32EC4NS00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal9.3 kg120.0 L/min100.0 ml/min50.0 msNBRNG10 / CETOP 05120 L/MINOperated in position a or bInternal / internal4 - 20 mAStandard12 - 20 mA = P-A6 + PER32
D41FBB31FC1NF00
Backordered
POR
PARKER3-WayProportionaln/aIndustrial Systems Division Europe60 °C-20 °C350 barSubplateNBRPilotHydraulicsCast IronUnrestrictedHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °CWater-Glycol According to DIN 51524 ... 53520 cStISO 4406; 18/16/13Proportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °C-25.0 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPA< 5 %Onboard18...30, ripple < 5 % eff., surge free V10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 bar30 + T/Y barIP65 in accordance with EN 60529set to 10 % command signal12.6 kg200.0 L/min200.0 ml/min75.0 msNBRNG16 / CETOP 07200 l/minOperated in position a or bInternal / external0 - ±10 VStandard0 - +10 V = P-B6 + PEB31

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains