The pilot operated proportional directional control valves series D*1FC is characterized by a high-precision position feedback system for improved process accuracy and and simple parametrization .

The D*1FC series is equipped with a modern, high-definition position feedback system. The parameters of the valve electronics can be accessed where required via the free, user-friendly ProPxD software. The integrated diagnostics function also makes optimal configuration easier.

D*1FC with EtherCAT
These valves are actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  E2analogue  command signal and diagnostic spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Rubber & tire processing

Features/Benefits:
• High-quality mechanical design - pilot valve is based on the tried and tested D1FB control valve with spool/sleeve design and guarantees pilot control with high precision
• Progressive flow characteristics - allows sensitive adjustment of flow rate
• Low hysteresis - ensures high repeatability and thus improved process and product accuracy
• High dynamics - suitable for demanding open loop applications
• High flow capacity - optimum efficiency in relation to valve size
• Parametrizable via Parker ProPxD soft - quick and easy adjustment of parameters
• Excellent price-performance ratio - fast return of investment
• Short delivery time - no storage necessary
• Centre position monitoring optional
• A-regeneration optional - for new energy saving circuits with differential cylinders
• Switchable hybrid version optional - can switch between regenerative mode and standard mode at any time
• Version with EtherCAT® interface, 2x M12x1 connector 4-Pin (EtherCAT® In and EtherCAT® Out)

Applications:
• General presses
• Tire presses
• Machine tool
• Injection molding
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandFunctionMaximum Flow RateDivisionMaximum Operating PressureMounting TypeSeal MaterialFor Fluid TypeOperation TypeTechnologyBody MaterialMounting PositionFlow RateMediaApplicationMinimum Fluid TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureElectronics TypeVibration ResistanceMaximum Pilot PressureIngress Protection RatingVariation of Opening PointPower Supply VoltageMinimum Pilot PressureWeightResponse TimeSeal MaterialFlow RateSpool CodeValve OptionSignal InputFlow DirectionConnection TypePilot Inlet / Drain LocationsPort ConnectionMaximum Ambient TemperatureFilter Efficiency RatingHysteresisMounting StyleLeak RateMaximum Operating TemperatureMinimum Operating Temperature
D41FCE01FC4NK70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportional20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard0-±10 V0-10 V = P-A6 + PE + enableInternal/internalNG16 / CETOP 07
D41FCE01FC4NS00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted200 L/min400 cSt-20 °CSolenoid20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard4-20 mA12-20 mA = P-A6 + PEInternal/internalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %NFPA200 ml/min
D41FCE01FC4NS70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoid20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard4-20 mA12-20 mA = P-A6 + PE + enableInternal/internalNG16 / CETOP 07
D41FCE01FC4VB00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolPilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msFPM200 l/minE01Standard0-±10 V0-10 V = P-B6 + PEInternal/internalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %ISO 4401200 ml/min
D41FCE01FC4VB70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-20 °C400 cSt-20 °CProportional20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msFPM200 l/minE01Standard0-±10 V0-10 V = P-B6 + PE + enableInternal/internalNG16 / CETOP 07
D41FCE01FC4VK00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateFPMWater-GlycolPilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msFPM200 l/minE01Standard0-±10 V0-10 V = P-A6 + PEInternal/internalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %NFPA200 ml/min
D41FCE01FC5NB08
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportional20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Monitor switch0-±10 V0-10 V = P-B6 + PEExternal/internalNG16 / CETOP 07
D41FCE01FC5NB70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotCast IronUnrestricted200 L/min400 cSt-20 °CSolenoid20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard0-±10 V0-10 V = P-B6 + PE + enableExternal/internalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %CETOP RP121200 ml/min
D41FCE01FC5NB78
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoid20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Monitor switch0-±10 V0-10 V = P-B6 + PE + enableExternal/internalNG16 / CETOP 0760 °C-20 °C
D41FCE01FC5NE00
Backordered
POR
Industrial Systems Division EuropeNBR200 l/minE01Standard0-±20 mA0-20 mA = P-B6 + PEExternal/internalNG16 / CETOP 07
D41FCE01FC5NK00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard0-±10 V0-10 V = P-A6 + PEExternal/internalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %NFPA200 ml/min
D41FCE01FC5NS00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportional20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE01Standard4-20 mA12-20 mA = P-A6 + PEExternal/internalNG16 / CETOP 07
D41FCE02FC1NB00
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±10 V0-10 V = P-B6 + PEInternal/externalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %ISO 4401200 ml/min
D41FCE02FC1NB08
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoid20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Monitor switch0-±10 V0-10 V = P-B6 + PEInternal/externalNG16 / CETOP 07
D41FCE02FC1NB70
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoid20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±10 V0-10 V = P-B6 + PE + enableInternal/externalNG16 / CETOP 07
D41FCE02FC1NB78
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Monitor switch0-±10 V0-10 V = P-B6 + PE + enableInternal/externalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %NFPA200 ml/min
D41FCE02FC1NE00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRWater-GlycolPilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CProportional20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±20 mA0-20 mA = P-B6 + PEInternal/externalNG16 / CETOP 07
D41FCE02FC1NE70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted200 L/min400 cSt-20 °CSolenoid20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±20 mA0-20 mA = P-B6 + PE + enableInternal/externalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %CETOP RP121200 ml/min
D41FCE02FC1NK00
Backordered
POR
PARKER3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotHydraulicsCast IronUnrestricted200 L/minHydraulic OilIndustrial Hydraulic-25 °C400 cSt-20 °CSolenoid20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±10 V0-10 V = P-A6 + PEInternal/externalNG16 / CETOP 07
D41FCE02FC1NK70
Backordered
POR
3-Wayn/aIndustrial Systems Division Europe350 barSubplateNBRHydraulic Oil According to DIN 51524 ... 535PilotCast IronUnrestricted200 L/min400 cSt-20 °CProportional20 cStProportional DC ValveOnboard10 Sinus 5...2000 Hz acc. IEC 68-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 68-2-36 15 Shock acc. IEC 68-2-27 g350 barIP65 in accordance with EN 60529set to 10 % command signal18...30, electric shut-off at < 17, ripple < 5 % eff., surge free V20 bar12.5 kg4.1 msNBR200 l/minE02Standard0-±10 V0-10 V = P-A6 + PE + enableInternal/externalNG16 / CETOP 0760 °CISO 4406 18/16/13≤ 0.1 %CETOP RP121200 ml/min