Parker’s kick-down pilot operated sequence valve provides fast responding and reliable performance for hydraulic circuits that require pressure to be eliminated once the max setting is achieved. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 160 lpm (42 gpm) and can be considered a hydraulic fuse. Parker’s kick-down pilot operated sequence valve is intended for clamping or press within industrial markets, but can also be use in mobile applications such as when attachments are used with quick disconnects and a fixed displacement pump.

Markets:
• Agriculture
• Aerial
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Integrated 250 micron screen
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• Clamping
• Power units
• Attachments/implements with quick disconnects

Additional Technical Insight:
Unlike relief valves which will reset slightly below their pressure setting, Parker’s B04C3 Kick-Down sequence valve will continue to unload pump flow until its supply flow is completely stopped.  Two adjustable pressure ranges are standard for 3000 or 6000 PSI maximum operating pressures, and each version is capable of flows up to 42 GPM.   Screw, knob, and tamper-resistant adjustment options are available.

B04C3 pilot operated cartridges are normally closed, internally piloted and externally drained.   The external drain prevents downstream pressure from having an effect on the valve setting.  When inlet pressure at port 1 is lower than the valve’s setting, flow is not allowed to exit port 2.  Once the pressure setting is reached, flow from port 1 is unloaded to port 2.  The valve does not reset and close until flow is completely removed from port 1.  Staying open after the setting is reached creates a requirement for an operator or the system controls to take steps of removing flow before the valve can stop unloading the pump.  Functioning in a manner similar to a fuse can provide additional over-pressurization protection and can also help to detect unusual high pressure machine conditions.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialMaximum Pressure SettingMaximum Operating PressureSeal MaterialMinimum Operating TemperatureFlow RateFor Fluid TypeDivisionCavity SizePilot LocationFilter Efficiency RatingMaximum Kinematic ViscosityMaximum Operating TemperatureMounting TypeActuation TypeDivisionOperation TypeValve MaterialAdjustment MechanismMaximum Tank PressureOperating TemperaturePressure Control RangeStandard Setting PressurePressure Control SensitivityMaximum Inlet Pressure RatingLeak RateConfigurationMaximum Flow RateInstallation TorqueWeightFunctionDrain OptionSeal MaterialAdjustment MechanismPressure Control RangeFlow Rate
B04C3HZN
Backordered
POR
N/A210 bar420 barNitrile-30 °F160 L/minSynthetic Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalSAE Class 445-2000 SSU (6 to 420 cSt)121 °CScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticHardened Steel (all operating parts)Screw6000 psi-30 to 250 °F10 to 210 bar100 bar30 bar Per Turn420 bar100 cm3/min @ 1450 Psi (100 bar)Kick Down42 Gal/min50 Nm0.55 lbPilot Operated SequenceExternalNitrileScrew145-3000 PSI, 10-210 BAR42 GAL/MIN, 160 L/MIN
B04C3PZN
Backordered
POR
N/A420 bar420 barNitrile-30 °F160 L/minMineral-based Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalSAE Class 445-2000 SSU (6 to 420 cSt)250 °FScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticSteel (all parts)Screw420 bar-30 to 250 °F10 to 420 bar2900 psi800 psi Per Turn420 bar100 cm3/min @ 1450 Psi (100 bar)Kick Down160 L/min50 Nm0.27 kgPilot Operated SequenceExternalNitrileScrew145-6000 PSI, 10-420 BAR42 GAL/MIN, 160 L/MIN