Parker’s pilot operated sequence valve with a built-in reverse check reduces manifold space, complexity, and the number of components in a hydraulic system. These valves can work with pressures up to 420 bar (6000 psi) and flows up to 70 lpm (18.5 gpm) and allow for multiple double acting functions to be operated with a single directional control valve. Parker’s pilot operated sequence valve with a built-in reverse check can be utilized in several applications, but is ideal for load control and clamping or press applications within mobile and industrial markets.

Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High pressure and flow capacity
• Integrated 250 micron screen
• Hardened, precision ground parts for durability
• All external parts zinc plated

Applications:
• Clamping
• Load holding
• Actuator control
• Motor control

Additional Technical Insight:
B04D3 is an internally piloted and externally drained sequence valve with an integrated reverse free flow check valve.  When pressure is below the sequence setting the valve is normally closed.  Once the pressure setting is reached the valve is internally piloted open allowing flow to a secondary branch of the circuit.  Flow from the secondary branch is allowed to free flow back to the primary branch via the reverse flow check.  The external drain should be plumbed directly back to tank to prevent downstream pressure from adding to the sequence setting.  Two adjustable pressure ranges are standard for 3000 or 6000 PSI maximum operating pressures, and each version is capable of flows up to 32 GPM.   Screw, knob, and tamper-resistant adjustment options are available.

Combining a sequencing function and reverse flow check into a single size 10 cartridge reduces manifold space, complexity and the number of components.  The integrated check valve reduces internal drillings and can also allow for multiple double acting functions to be operated with a single directional control valve.  Parker’s B04D3 offers design flexibility that can be utilized in many applications including:  Clamp and Drill, Machine Tools, Presses, Power Units, Material Handling, Construction, and Agriculture.
Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceBody MaterialWeightSeal MaterialMinimum Operating TemperatureMaximum Operating PressureFor Fluid TypeDivisionCavity SizePilot LocationFilter Efficiency RatingMaximum Kinematic ViscosityMaximum Operating TemperatureMounting TypeActuation TypeMaximum Pressure SettingDivisionOperation TypeValve MaterialAdjustment MechanismMaximum Tank PressureOperating TemperaturePressure Control RangeStandard Setting PressurePressure Control SensitivityMaximum Inlet Pressure RatingInstallation TorqueFlow RateMaximum Flow RateFunctionLeak RateDrain OptionConfigurationSeal MaterialAdjustment MechanismPressure Control RangeFlow Rate
B04D3HWN
Backordered
POR
N/A0.25 kgNitrile-30 °F6000 psiMineral-based Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalISO 4406 18/16/1345-2000 SSU (6 to 420 cSt)121 °CScrew-in CartridgePressure Sensing3000 psiMobile Hydraulic Systems Division EuropeAutomaticSteel (all parts)Knob6000 psi-30 to 250 °F10 to 210 bar1450 psi435 psi Per Turn420 bar50 Nm18.5 Gal/min18.5 Gal/minPilot Operated Sequence50 drops/min @ 1450 Psi (100 bar)ExternalReverse Flow CheckNitrileKnob145-3000 PSI, 10-210 BAR18.5 GAL/MIN, 70 L/MIN
B04D3HZN
Backordered
POR
N/A0.55 lbNitrile-30 °F6000 psiMineral-based Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalSAE Class 445-2000 SSU (6 to 420 cSt)121 °CScrew-in CartridgePressure Sensing210 barMobile Hydraulic Systems Division EuropeAutomaticHardened Steel (all operating parts)Screw420 bar-34 to 121 °C145 to 3000 psi1450 psi30 bar Per Turn6000 psi37 lb-ft70 L/min70 L/minPilot Operated Sequence50 drops/min @ 1450 Psi (100 bar)ExternalReverse Flow CheckNitrileScrew145-3000 PSI, 10-210 BAR18.5 GAL/MIN, 70 L/MIN
B04D3PZN
Backordered
POR
N/A0.55 lbNitrile-30 °F420 barSynthetic Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalISO 4406 18/16/1345-2000 SSU (6 to 420 cSt)250 °FScrew-in CartridgePressure Sensing6000 psiMobile Hydraulic Systems Division EuropeAutomaticSteel (all parts)Screw420 bar-34 to 121 °C10 to 420 bar200 bar55 bar Per Turn6000 psi37 lb-ft18.5 Gal/min70 L/minPilot Operated Sequence50 drops/min @ 1450 Psi (100 bar)ExternalReverse Flow CheckNitrileScrew145-6000 PSI, 10-420 BAR18.5 GAL/MIN, 70 L/MIN
B04D3PZV
Backordered
POR
N/A0.55 lbFluorocarbon-26 °C6000 psiMineral-based Hydraulic FluidsHydraulic Cartridge Systems DivisionC10-3SInternalSAE Class 445-2000 SSU (6 to 420 cSt)204 °CScrew-in CartridgePressure Sensing420 barMobile Hydraulic Systems Division EuropeAutomaticSteel (all parts)Screw6000 psi-26 to 204 °C145 to 6000 psi2900 psi55 bar Per Turn6000 psi37 lb-ft70 L/min18.5 Gal/minPilot Operated Sequence50 drops/min @ 1450 Psi (100 bar)ExternalReverse Flow CheckFluorocarbonScrew145-6000 PSI, 10-420 BAR18.5 GAL/MIN, 70 L/MIN