Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

Picture for category Pilot Operated Servo Proportional Directional Control Valve - Series D31FP / D41FP / D91FP / D111FP

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The top-level series of pilot operated servo proportional valves D*1FP is the ultimate choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. It shows extremly high dynamics combined with high flow. It  The D*1FP series transfers the advantages of the Parker patented Voice Coil Drive (VCD) to larger frame sizes and thus high flow rates. The high dynamics/ high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

The D*1FP series is available in 5 sizes:
• D31FP NG10 (CETOP 05)
• D41FP NG16 (CETOP 07)
• D91FP NG25 (CETOP 08) for port diameter up to 32 mm
• D111FP NG32 (CETOP 10)

Optionally available with EtherCAT® interface
The valves series D*1FP with EtherCAT® interface fulfill  the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Highest dynamics - shorter cycle times and thus higher machine output
• High flow capacity - optimum efficiency in relation to valve size
• High-resolution position feedback on main spool - assures stable spool position
• Progressive main spool design (sinus characteristics) - high-resolution position control at small command signals and for high flows where desirable
• Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools)
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Digital electronics - permits to store and load valve records
• Optionally with EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-CAT In and EtherCAT Out) - high dynamics can be also utilized within the fieldbus system
• Very robust valve design - lower costs through less downtime
• Short delivery time - no warehousing necessary

Applications:
• General presses
• Die cast
• Injection molding
• Pulp & paper

Technical specifications:
The safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 10 % spring offset to spool position A or B (for zerolap spools).

Note: The versions with Regenerative or hybrid function are no longer available.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandMediaWeightDivisionFunctionFlow RateLeak RateHysteresisTechnologyValve TypeApplicationBody MaterialMounting TypeResponse TimeSeal MaterialActuation TypeFor Fluid TypeMounting StyleOperation TypeProduct SeriesPort ConnectionElectronics TypeMaximum Flow RateMounting PositionDivisionPower Supply VoltageVibration ResistancePressure DifferentialMaximum Pilot PressureMinimum Pilot PressureFilter Efficiency RatingIngress Protection RatingMaximum Fluid TemperatureMinimum Fluid TemperatureMaximum Operating PressureVariation of Opening PointMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMinimum Kinematic ViscosityFlow RateSpool CodeSpool TypeSignal InputValve OptionSeal MaterialFlow DirectionConnection TypePort ConnectionMaximum Flow RatePressure Differential (bar)Pilot Inlet / Drain LocationsDefined Spool Position At Power Down
D41FPE01FC4NB00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-B6+PENG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NB70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG16 / CETOP 07Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-645.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-B6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NE70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535NFPAPilotProportional DC ValveNG10 / CETOP 05Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±20 mAStandard and regenerative valve functionNBR0-20 mA = P-B6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NK00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-A6+PENG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NK70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG25 / CETOP 08Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeSurge Free V % Eff.15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-A6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NS00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535ISO 4401PilotProportional DC ValveNG25 / CETOP 08Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeSurge Free V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap4-20 mAStandard and regenerative valve functionNBR12-20 mA = P-A6+PENG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4NS70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap4-20 mAStandard and regenerative valve functionNBR12-20 mA = P-A6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4VB00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msFPMVCD®-actuatorHydraulic OilISO 4401PilotProportional DC ValveNG25 / CETOP 08Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-645.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionFPM0-10 V = P-B6+PENG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4VB70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msFPMVCD®-actuatorOthersDIN 24340PilotProportional DC ValveNG16 / CETOP 07Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionFPM0-10 V = P-B6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC4VS70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msFPMVCD®-actuatorOthersDIN 24340PilotProportional DC ValveNG10 / CETOP 05Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap4-20 mAStandard and regenerative valve functionFPM12-20 mA = P-A6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/internalCenter position
D41FPE01FC5NS00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535NFPAPilotProportional DC ValveNG10 / CETOP 05Onboard600 L/minPreferably HorizontalIndustrial Systems Division Europe24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap4-20 mAStandard and regenerative valve functionNBR12-20 mA = P-A6+PENG16 / CETOP 07600 L/MIN5External/internalCenter position
D41FPE01FC5VB00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msFPMVCD®-actuatorOthersISO 4401PilotProportional DC ValveNG25 / CETOP 08Onboard600 L/minPreferably HorizontalIndustrial Systems Division Europe24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE01Overlap0-±10 VStandard and regenerative valve functionFPM0-10 V = P-B6+PENG16 / CETOP 07600 L/MIN5External/internalCenter position
D41FPE02FC1HE70
Backordered
POR
Industrial Systems Division Europe200 l/minE02Overlap0-±20 mAStandard and regenerative valve functionfor HFC fluid0-20 mA = P-B6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/externalCenter position
D41FPE02FC1NB00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG10 / CETOP 05Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-645.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-B6+PENG16 / CETOP 07600 L/MIN5Internal/externalCenter position
D41FPE02FC1NK70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG16 / CETOP 07Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-645.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-A6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/externalCenter position
D41FPE02FC1NS00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535NFPAPilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeSurge Free V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap4-20 mAStandard and regenerative valve functionNBR12-20 mA = P-A6+PENG16 / CETOP 07600 L/MIN5Internal/externalCenter position
D41FPE02FC1NS70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535CETOP RP121PilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division Europe24 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-65.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap4-20 mAStandard and regenerative valve functionNBR12-20 mA = P-A6+PE + enableNG16 / CETOP 07600 L/MIN5Internal/externalCenter position
D41FPE02FC2NB00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535ISO 4401PilotProportional DC ValveNG25 / CETOP 08Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-B6+PENG16 / CETOP 07600 L/MIN5External/externalCenter position
D41FPE02FC2NB70
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division EuropeProportional200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG16 / CETOP 07Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-275.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-B6+PE + enableNG16 / CETOP 07600 L/MIN5External/externalCenter position
D41FPE02FC2NK00
Backordered
POR
PARKERHydraulic Oil14.2 kgIndustrial Systems Division Europe3-Way200 L/minDepending on Spool< 0.1 %HydraulicsProportional DC ValveIndustrial HydraulicCast IronSubplate13 msNBRVCD®-actuatorHydraulic Oil According to DIN 51524 ... 535DIN 24340PilotProportional DC ValveNG32 / CETOP 10Onboard600 L/minPreferably HorizontalIndustrial Systems Division EuropeSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-645.0 bar350 bar20 barISO 4406 18/16/13IP65 in accordance with EN 6052960 °C-20 °C350 barset to 10 % command signal60 °C400 cSt-20 °C20 cSt200 l/minE02Overlap0-±10 VStandard and regenerative valve functionNBR0-10 V = P-A6+PENG16 / CETOP 07600 L/MIN5External/externalCenter position

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.

Exact match Begins with Contains