The top-level series of pilot operated servo proportional valves D*1FP is the ultimate choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. It shows extremly high dynamics combined with high flow. It  The D*1FP series transfers the advantages of the Parker patented Voice Coil Drive (VCD) to larger frame sizes and thus high flow rates. The high dynamics/ high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves.

The D*1FP series is available in 5 sizes:
• D31FP NG10 (CETOP 05)
• D41FP NG16 (CETOP 07)
• D91FP NG25 (CETOP 08) for port diameter up to 32 mm
• D111FP NG32 (CETOP 10)

Optionally available with EtherCAT® interface
The valves series D*1FP with EtherCAT® interface fulfill  the requirements of modern communication between valve and main control. Due to high data transmission speed and short cycle times, the high dynamics can be also utilized within the fieldbus system.

Markets:
• Industrial
• Machine tools
• Molding

Features/Benefits:
• Highest dynamics - shorter cycle times and thus higher machine output
• High flow capacity - optimum efficiency in relation to valve size
• High-resolution position feedback on main spool - assures stable spool position
• Progressive main spool design (sinus characteristics) - high-resolution position control at small command signals and for high flows where desirable
• Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools)
• IO-Link interface for parametrizing
• RGB diode for optical status check
• NFC interface
• Digital electronics - permits to store and load valve records
• Optionally with EtherCAT interface, 2x M12x1, connector 4-Pin (Ether-CAT In and EtherCAT Out) - high dynamics can be also utilized within the fieldbus system
• Very robust valve design - lower costs through less downtime
• Short delivery time - no warehousing necessary

Applications:
• General presses
• Die cast
• Injection molding
• Pulp & paper

Technical specifications:
The safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 10 % spring offset to spool position A or B (for zerolap spools).

Note: The versions with Regenerative or hybrid function are no longer available.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceBrandDivisionMaximum Operating PressureMounting TypeSeal MaterialOperation TypeTechnologyBody MaterialMediaApplicationMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureMinimum Fluid TemperatureFlow RateMaximum Flow RateFilter Efficiency RatingFor Fluid TypeMinimum Kinematic ViscosityValve TypeDivisionProduct SeriesMaximum Fluid TemperatureElectronics TypeMaximum Pilot PressureIngress Protection RatingVariation of Opening PointMounting StyleMinimum Pilot PressureWeightFunctionResponse TimeActuation TypeMounting PositionPower Supply VoltageVibration ResistanceLeak RateHysteresisPort ConnectionPressure DifferentialSeal MaterialPort ConnectionFlow RateSignal InputFlow DirectionPilot Inlet / Drain LocationsSpool CodeValve OptionConnection TypeSpool TypeMaximum Flow RatePressure Differential (bar)Defined Spool Position At Power Down
D111FPE52LB2NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalISO 440120 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG10 / CETOP 055.0 barNBRNG32 / CETOP 101000 l/min4-20 mA12-20 mA = P-AExternal/externalE52Standard and regenerative valve function6+PEZerolap3000 L/MIN5P-B/A-T
D111FPE52LB4NB70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG32 / CETOP 105.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-BInternal/internalE52Standard and regenerative valve function6+PE + enableZerolap3000 L/MIN5P-B/A-T
D111FPE52LB4NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalISO 440120 bar64.5 kg3-Way45 msVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AInternal/internalE52Standard and regenerative valve function6+PEZerolap3000 L/MIN5P-B/A-T
D111FPE52LB5NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalSurge Free V % Eff.15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG32 / CETOP 105.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/internalE52Standard and regenerative valve function6+PEZerolap3000 L/MIN5P-B/A-T
D111FPE52LB5NK70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG32 / CETOP 105.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/internalE52Standard and regenerative valve function6+PE + enableZerolap3000 L/MIN5P-B/A-T
D111FPE52LC2HK70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateFor HFC FluidPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Water-Glycol20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG25 / CETOP 085.0 barfor HFC fluidNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/externalE52Standard and regenerative valve function6+PE + enableZerolap3000 L/MIN5Center position
D111FPE52LC2NE70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalISO 440120 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalSurge Free V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG32 / CETOP 101000 l/min0-±20 mA0-20 mA = P-BExternal/externalE52Standard and regenerative valve function6+PE + enableZerolap3000 L/MIN5Center position
D111FPE52LC2NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/externalE52Standard and regenerative valve function6+PEZerolap3000 L/MIN5Center position
D111FPE52LC2NK70
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/externalE52Standard and regenerative valve function6+PE + enableZerolap3000 L/MIN5Center position
D111FPE52LC4NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG32 / CETOP 105.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AInternal/internalE52Standard and regenerative valve function6+PEZerolap3000 L/MIN5Center position
D111FPR31LC4NK50
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG16 / CETOP 075.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AInternal/internalR31Standard and regenerative valve function11+PEOverlap3000 L/MIN5Center position
D111FPR61LB2NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalNFPA20 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG16 / CETOP 075.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-BExternal/externalR61Standard and regenerative valve function6+PEZerolap3000 L/MIN5P-B/A-T
D111FPR61LB2NK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar64.5 kgProportional45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/externalR61Standard and regenerative valve function6+PEZerolap3000 L/MIN5P-B/A-T
D111FPZ31LC2NE0L
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalISO 440120 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG10 / CETOP 055.0 barNBRNG32 / CETOP 101000 l/min0-±20 mA0-20 mA = P-BExternal/externalZ31Hybrid function6+PEOverlap3000 L/MIN5Center position
D111FPZ31LC2NK0L
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalSurge Free V % Eff.10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG16 / CETOP 075.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-AExternal/externalZ31Hybrid function6+PEOverlap3000 L/MIN5Center position
D111FPZ61LB2NB7L
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-25 °C1000 L/min3000 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar64.5 kg3-Way45 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG10 / CETOP 055.0 barNBRNG32 / CETOP 101000 l/min0-±10 V0-10 V = P-BExternal/externalZ61Hybrid function6+PE + enableZerolap3000 L/MIN5P-B/A-T
D31FPB31DC2NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C90 L/min250 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar11.3 kgProportional10 msVCD®-actuatorPreferably HorizontalRipple < 5 V % Eff.10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG10 / CETOP 055.0 barNBRNG10 / CETOP 0590 l/min0-±10 V0-10 V = P-BExternal/externalB31Standard and regenerative valve function6+PEOverlap250 L/MIN5Center position
D31FPB31DC2NS00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C90 L/min250 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalCETOP RP12120 bar11.3 kgProportional10 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 Sinus 5...2000 Hz Acc. IEC 60068-2-6Depending on Spool< 0.1 %NG10 / CETOP 055.0 barNBRNG10 / CETOP 0590 l/min4-20 mA12-20 mA = P-AExternal/externalB31Standard and regenerative valve function6+PEOverlap250 L/MIN5Center position
D31FPB31EC2VK00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateFPMPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C120 L/min250 L/minISO 4406 18/16/13Hydraulic Oil20 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar11.3 kg3-Way10 msVCD®-actuatorPreferably Horizontal24 V Nominal (tolerance range 22 … 30)15 Shock Acc. IEC 60068-2-27Depending on Spool< 0.1 %NG16 / CETOP 075.0 barFPMNG10 / CETOP 05120 L/MIN0-±10 V0-10 V = P-AExternal/externalB31Standard and regenerative valve function6+PEOverlap250 L/MIN5Center position
D31FPB31EC4NB00
Backordered
POR
PARKERIndustrial Systems Division Europe350 barSubplateNBRPilotHydraulicsCast IronHydraulic OilIndustrial Hydraulic60 °C400 cSt-20 °C-20 °C120 L/min250 L/minISO 4406 18/16/13Hydraulic Oil According to DIN 51524 ... 53520 cStProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve60 °COnboard350 barIP65 in accordance with EN 60529set to 10 % command signalDIN 2434020 bar11.3 kg3-Way10 msVCD®-actuatorPreferably HorizontalElectric Shut-off at < 19 V Nominal (tolerance range 22 … 30)10 (RMS) Random Noise 20...2000 Hz Acc. IEC 60068-2-64Depending on Spool< 0.1 %NG25 / CETOP 085.0 barNBRNG10 / CETOP 05120 L/MIN0-±10 V0-10 V = P-BInternal/internalB31Standard and regenerative valve function6+PEOverlap250 L/MIN5Center position