Portable Ash Instrument Analyser - Ash Probe Series

Picture for category Portable Ash Instrument Analyser - Ash Probe Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker Ash Probe measures the natural gamma radiation emitted by the impurities that make up the ash content of coal (Thorium, Potassium, etc.). It does not contain a radiation source and is therefore perfectly safe and requires no special training to use. It also provides significant reductions in time delays in gaining accurate ash results.

Other clear benefits from using the Parker Ash Probe, range from financial savings in sampling and analysis costs to improved consistency in saleable product. This latter benefit is possible because the rapid results from the Parker Ash Probe allows plant operators to adjust washing densities quickly in order to maximize yield at a given ash content or blend coals more accurately in real time.

The Parker Ash Probe comprises two parts: the probe and the display unit. The probe is inserted into the coal pile and connected to the lightweight AshGraffix colour touch-screen display unit. Within a minute, the ash content of that area will have been measured and displayed. Taking measurements from several key areas of the pile or truck will give an accurate overall ash content.

The unit is calibrated to the source(s) of coal to be measured and can then measure the accuracy of the ash content to around 0.3%.

Industries:
• Mining
• Cement plants
• Steel plants using Coking Coal as fuel source
• Coal Preparation Plants
• Coal Briquette plants

Features/Benefits
• Simple to use, easy to calibrate
• Much quicker than conventional sampling and analysis
• Reduced sampling effort, leading to reduced costs
• More information on ash and ash variability
• High resolution colour touch-screen display
• Multi language user interface with more languages being added all the time
• Can operate for a full working day on a single charge
• Measurement accuracy: better than 0.3% ash content
• Data can be written to a USB memory stick for offline analysis
• Data can be uploaded to a PC using the supplied software and cable (Windows XP/7/8/8.1 compatible)
• Environmental rating: IP65
• Stores data for up to 99 piles (99 samples each) or 600 wagons/trucks (12 samples each)
• Stores up to 100 sets of calibration coefficients
• Minimum Sample Measurement Time: 60 seconds
• Maximum Sample Measurement Time: 600 seconds
• Operating Temperature Range: -20°C to +55°C

Applications:
• Run of mine (ROM) coal
• Washed product (smalls, peas, beans, duff, singles, doubles etc)
• Screened coal (dry fines, PSF etc)
• Slurry
• Blended products
• Final product (e.g. composite ash pile)
• Discard
• Unknown coals prior to blending
• Rail or truck coal deliveries to blending plants
• Rail or truck coal deliveries to power stations, cement works and steel works
• Rail or truck coal deliveries to coking plants
• Rail or truck coal deliveries to washing plants

Read More...
Sort by
Display per page
ActionSKUAvailabilityPriceTechnologyBrandBody MaterialDivisionSensing MethodAccuracyWidthProduct StyleAccessories IncludedWeightSpecifications MetLengthMaterials of ConstructionCable TypeHeightElectrical ConnectionDiameterOperating TemperatureCommunication InterfaceCycle TimeIndustryTube LengthTube Outside DiameterSafety FeaturesProduct TypeDivisionApplicationCable LengthElectrical ConnectionAccessories IncludedCable TypeHead MaterialCable LengthElectrical Requirements
BM0600AECL03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmEURProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitEURCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium3 m Probe to Display Unit
BM0600AECL10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmEURProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitEURCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium10 m Probe to Display Unit
BM0600AENB03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmEURProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitEUR2 x 10 m cables in place of calibration kitStandard climate cableAluminium3 m Probe to Display Unit
BM0600AENB10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmEURProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitEUR2 x 10 m cables in place of calibration kitStandard climate cableAluminium10 m Probe to Display Unit
BM0600AENL03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmEURProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitEURCalibration kitStandard climate cableAluminium3 m Probe to Display Unit
BM0600AENL10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmEURProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitEURCalibration kitStandard climate cableAluminium10 m Probe to Display Unit
BM0600AKCB03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUKProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUK2 x 10 m cables in place of calibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium3 m Probe to Display Unit
BM0600AKCB10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUKProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUK2 x 10 m cables in place of calibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium10 m Probe to Display Unit
BM0600AKCL03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUKProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUKCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium3 m Probe to Display Unit
BM0600AKCL10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUKProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUKCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium10 m Probe to Display Unit
BM0600AKNB03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUKProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUK2 x 10 m cables in place of calibration kitStandard climate cableAluminium3 m Probe to Display Unit
BM0600AKNB10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUKProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUK2 x 10 m cables in place of calibration kitStandard climate cableAluminium10 m Probe to Display Unit
BM0600AKNL03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUKProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUKCalibration kitStandard climate cableAluminium3 m Probe to Display Unit
BM0600AKNL10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUKProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUKCalibration kitStandard climate cableAluminium10 m Probe to Display Unit
BM0600AUCB03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUSProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUS2 x 10 m cables in place of calibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium3 m Probe to Display Unit2-pin plug
BM0600AUCB10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUSProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUS2 x 10 m cables in place of calibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium10 m Probe to Display Unit2-pin plug
BM0600AUCL03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUSProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUSCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium3 m Probe to Display Unit2-pin plug
BM0600AUCL10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality MonitorCalibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Display Unit: 168 mmUSProbe: 52 mm-4 to 1022 °FAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUSCalibration kitLAPP OLFLEX 440 CP 3G 0.5 Cold climate cable from probe to display unit (-40°C to + 90°C)Aluminium10 m Probe to Display Unit2-pin plug
BM0600AUNB03
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUSProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring3 m Probe to Display UnitUS2 x 10 m cables in place of calibration kitStandard climate cableAluminium3 m Probe to Display Unit2-pin plug
BM0600AUNB10
Backordered
POR
Process ControlBretby GammatechStainless SteelInstrumentation Products DivisionNatural Gamma0.3 %Display Unit: 220 mmCoal Ash Quality Monitor2 x 10 m cables in place of calibration kitProbe: 2.9 kgIP65 Environmental Rating760 mmHead: AluminiumStandard climate cableDisplay Unit: 168 mmUSProbe: 52 mm-20 to 550 °CAshGraffix60 secondMining760 mm52 mmNon Radiation - Detects Natural GammaCondition MonitorInstrumentation Products DivisionCoal Ash Quality Monitoring10 m Probe to Display UnitUS2 x 10 m cables in place of calibration kitStandard climate cableAluminium10 m Probe to Display Unit2-pin plug

REWARD Status

Previous Reward Dollars Spent: $0.00. Register or Sign In so we can keep track of your Reward dollars spent.
Interchange Lookup

Interchange Lookup

Parker Interchange

Your one-stop-shop for all your filtration, hydraulic, pneumatic, hose, fittings, coupling and other motion control products. Click here for the dedicated page for you cross-reference or replacement search that also shows availability and price.