*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Action | SKU | Availability | Price | Body Material | Maximum Operating Pressure | Connection Size | Connection Type | Division | Division | Minimum Operating Temperature | Maximum Kinematic Viscosity | Maximum Operating Temperature | Weight | Flow Rate | Maximum Inlet Pressure Rating | Actuation Type | Operation Type | Installation Torque | Coil Nut Tightening Torque | Maximum Flow Rate | For Fluid Type | Frequency | Configuration | Valve Material | Filter Efficiency Rating | Leak Rate | Operating Temperature | Seal Material | Coil Type | Power Consumption | Function | Hysteresis | Cavity Size | Flow Direction | Minimum Pressure Differential | Current | Configuration | Maximum Flow Rate | Seal Material |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FAPC101C | Backordered | POR | N/A | 210 bar | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -37 °C | 45-2000 SSU (6 to 420 cSt) | +200 °F | 0.52 lb | 38 L/min | 3000 psi | Electrical | Solenoid Operated | 34 Nm | 4.1 Nm | 38 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Closed | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -37 to +93 °C | D-Ring | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | 3X | Top to Side (3 - 2) | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | D-Ring | |
FAPC101CN | Backordered | POR | N/A | 210 bar | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -30 °F | 45-2000 SSU (6 to 420 cSt) | +250 °F | 0.24 kg | 10 Gal/min | 3000 psi | Electrical | Solenoid Operated | 25 lb-ft | 4.1 Nm | 10 Gal/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Closed | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -34 to +121 °C | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | 3X | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | Nitrile | |
FAPC101CV | Backordered | POR | N/A | 3000 psi | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -26 °C | 45-2000 SSU (6 to 420 cSt) | +400 °F | 0.52 lb | 10 Gal/min | 210 bar | Electrical | Solenoid Operated | 34 Nm | 3 lb-ft | 38 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Closed | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -15 to +400 °F | Fluorocarbon | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | 3X | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 10 GAL/MIN, 38 L/MIN | Fluorocarbon | |
FAPC101N | Backordered | POR | N/A | 3000 psi | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -37 °C | 45-2000 SSU (6 to 420 cSt) | +93 °C | 0.24 kg | 10 Gal/min | 210 bar | Electrical | Solenoid Operated | 25 lb-ft | Finger Tight Nm | 38 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Open | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -35 to +200 °F | D-Ring | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | 3X | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 10 GAL/MIN, 38 L/MIN | D-Ring | |
FAPC101NN | Backordered | POR | N/A | 210 bar | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -30 °F | 45-2000 SSU (6 to 420 cSt) | +121 °C | 0.52 lb | 10 Gal/min | 210 bar | Electrical | Solenoid Operated | 34 Nm | Finger Tight Nm | 10 Gal/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Open | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | 3X | Top to Side (3 - 2) | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 10 GAL/MIN, 38 L/MIN | Nitrile | |
FAPC121CN | Backordered | POR | N/A | 210 bar | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -34 °C | 45-2000 SSU (6 to 420 cSt) | +250 °F | 0.79 lb | 57 L/min | 3000 psi | Electrical | Solenoid Operated | 48 Nm | 4.1 Nm | 57 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Closed | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | C12-3L | Top to Side (3 - 2) | 500 psi | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 15 GAL/MIN, 57 L/MIN | Nitrile | |
FAPC121NN | Backordered | POR | N/A | 3000 psi | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -30 °F | 45-2000 SSU (6 to 420 cSt) | +121 °C | 0.36 kg | 15 Gal/min | 210 bar | Electrical | Solenoid Operated | 48 Nm | Finger Tight Nm | 57 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Open | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | C12-3L | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 15 GAL/MIN, 57 L/MIN | Nitrile | |
FAPC161CN | Backordered | POR | N/A | 210 bar | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -34 °C | 45-2000 SSU (6 to 420 cSt) | +250 °F | 1.08 lb | 83 L/min | 210 bar | Electrical | Solenoid Operated | 80-85 lb-ft | 3 lb-ft | 83 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Closed | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -30 to +250 °F | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | C16-3 | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Closed | 22 GAL/MIN, 83 L/MIN | Nitrile | |
FAPC161NN | Backordered | POR | N/A | 3000 psi | n/a | n/a | Hydraulic Systems Division | Hydraulic Cartridge Systems Division | -34 °C | 45-2000 SSU (6 to 420 cSt) | +121 °C | 1.08 lb | 83 L/min | 210 bar | Electrical | Solenoid Operated | 80-85 lb-ft | Finger Tight Nm | 83 L/min | Mineral-based or synthetic hydraulic fluids | 100-400 Hz | Normally Open | All parts steel. All operating parts hardened steel | ISO 4406 18/16/13, SAE Class 4 | 5 @ 3000 PSI (210 BAR) drops/min | -34 to +121 °C | Nitrile | 5/8" Super Coil Low Watt (CAS) | 18 W | Proportional Pressure Compensated Flow Control/Regulator | < 10% | C16-3 | Top to Side (3 - 2) | 34 bar | Max: 1.5 @ 12 VDC, 0.75 @ 24 VDC A | Normally Open | 22 GAL/MIN, 83 L/MIN | Nitrile |