Action | SKU | Availability | Price | Function | Actuation Type | Minimum Operating Temperature | Division | Maximum Operating Temperature | Maximum Operating Pressure | Mounting Type | Seal Material | Body Material | Operation Type | Mounting Position | Weight | Maximum Flow Rate | Port Connection | Product Series | For Fluid Type | Seal Material | Spool Position | Signal Input | Function | Solenoid Connection | Pressure Control Range | Flow Rate | Maximum Pressure Setting |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D1FVE02CC0NF03 | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 25 | |||
D1FVE02CC0NG03 | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±20 mA | 0 - +20 mA = P-A | 6 + PE | 25 | |||
D1FVE02CC0NM03 | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±10 V | 0 - +10 V = P-B | 6 + PE | 25 | |||
D1FVE02CC0NS03 | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 4 - 20 mA | 12 - 20 mA = P-A | 6 + PE | 25 | |||
D1FVE02CC0NW53 | Backordered | POR | 3-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±10 V, 4 - 20 mA, 0 - ±20 mA | 0 - +10 V, 12 - 20 mA, 0 - +20 mA = P-A | 11 + PE | 25 | |||
D1FVE02CC0VF03 | Backordered | POR | 3-Way | Proportional | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position a or b | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 25 | |||
D1FVE02CC0VM03 | Backordered | POR | 3-Way | Solenoid | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position a or b | 0 - ±10 V | 0 - +10 V = P-B | 6 + PE | 25 | |||
D1FVE02CC0VS03 | Backordered | POR | 3-Way | Proportional | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position a or b | 4 - 20 mA | 12 - 20 mA = P-A | 6 + PE | 25 | |||
D1FVE02CC0VW53 | Backordered | POR | 3-Way | Proportional | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position a or b | 0 - ±10 V, 4 - 20 mA, 0 - ±20 mA | 0 - +10 V, 12 - 20 mA, 0 - +20 mA = P-A | 11 + PE | 25 | |||
D1FVE02CE0NF03 | Backordered | POR | 2-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 25 | |||
D1FVE02CE0NM03 | Backordered | POR | 2-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a | 0 - ±10 V | 0 - +10 V = P-B | 6 + PE | 25 | |||
D1FVE02CE0NS03 | Backordered | POR | 2-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a | 4 - 20 mA | 12 - 20 mA = P-A | 6 + PE | 25 | |||
D1FVE02CE0NW53 | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a | 0 - ±10 V, 4 - 20 mA, 0 - ±20 mA | 0 - +10 V, 12 - 20 mA, 0 - +20 mA = P-A | 11 + PE | 25 | |||
D1FVE02CK0NF03 | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position b | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 25 | |||
D1FVE02CK0NM03 | Backordered | POR | 2-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position b | 0 - ±10 V | 0 - +10 V = P-B | 6 + PE | 25 | n/a | n/a | |
D1FVE02CK0VF03 | Backordered | POR | 2-Way | Solenoid | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position b | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 25 | |||
D1FVE02CK0VS03 | Backordered | POR | 2-Way | Proportional | -20 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | FPM | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Water-Glycol | FPM | Operated in position b | 4 - 20 mA | 12 - 20 mA = P-A | 6 + PE | 25 | |||
D1FVE02DC0NF03 | Backordered | POR | 3-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±10 V | 0 - +10 V = P-A | 6 + PE | 45 | |||
D1FVE02DC0NS03 | Backordered | POR | 3-Way | Solenoid | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 4 - 20 mA | 12 - 20 mA = P-A | 6 + PE | 45 | |||
D1FVE02DC0NW53 | Backordered | POR | 3-Way | Proportional | -25 °C | Industrial Systems Division Europe | 60 °C | 350 bar | Subplate | NBR | Cast Iron | Direct | Unrestricted | 2.9 kg | 10 L/min | NG06 / CETOP 03 | Proportional DC Valve | Hydraulic Oil According to DIN 51524...535 | NBR | Operated in position a or b | 0 - ±10 V, 4 - 20 mA, 0 - ±20 mA | 0 - +10 V, 12 - 20 mA, 0 - +20 mA = P-A | 11 + PE | 45 | n/a | n/a |