Parker’s PR series pilot operated pressure reducing/relieving valves have an integral relieving function which limits the secondary circuit pressure. Options are A port control, B port control and P port control. The A & B valves feature a reverse flow check.

Markets:
• Factory Automation
• Lumber & Wood
• Machine Tools
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Packaging Machinery
• Plastic Processing
• Primary Metal Refining Process
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Available in 4 port sizes
• High flow capacity
• With integral return flow check valve on A & B port models

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPriceMounting TypeFilter Efficiency RatingMaximum Operating TemperatureBody MaterialProduct StyleMaximum Operating PressureMinimum Operating TemperatureMediaSeal MaterialMaximum Flow RateDivisionActuation TypeWeightPressure Range (psi)Port ConnectionValve Body MaterialSizeSeal Material
PR05AA10NA
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FAuminumPilot Operated Pressure Reducing/Relieving207 bar-4 °FOilNitrile20 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure3.1 lb100 to 3000Pressure Reducing in A w/check valveAluminumNFPA D05; CETOP 5; NG10Nitrile
PR05AA20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving345 bar-4 °FOilNitrile20 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure2.8 kg150 to 4500Pressure Reducing in A w/check valveDuctile IronNFPA D05; CETOP 5; NG10Nitrile
PR05BB10NA
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FAuminumPilot Operated Pressure Reducing/Relieving207 bar-4 °FOilNitrile20 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure3.1 lb100 to 3000Pressure Reducing in B w/check valveAluminumNFPA D05; CETOP 5; NG10Nitrile
PR05BB20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving345 bar-4 °FOilNitrile20 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure6.2 lb150 to 4500Pressure Reducing in B w/check valveDuctile IronNFPA D05; CETOP 5; NG10Nitrile
PR07BB20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving345 bar-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure12.6 lb150 to 4500Pressure Reducing in B w/check valveDuctile IronNFPA D07; CETOP 7; NG16Nitrile
PR07PP20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving345 bar-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure17.1 lb150 to 4500Pressure Reducing in PDuctile IronNFPA D07; CETOP 7; NG16Nitrile
PR08AA10NA
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FAuminumPilot Operated Pressure Reducing/Relieving207 bar-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure4.9 kg100 to 3000Pressure Reducing in A w/check valveAluminumNFPA D08; CETOP 8; NG25Nitrile
PR08AA20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving345 bar-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure10.4 lb150 to 4500Pressure Reducing in A w/check valveDuctile IronNFPA D08; CETOP 8; NG25Nitrile
PR08BB20ND
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FDuctile IronPilot Operated Pressure Reducing/Relieving5000 psi-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure24.7 lb150 to 4500Pressure Reducing in B w/check valveDuctile IronNFPA D08; CETOP 8; NG25Nitrile
PR08PP10NA
Backordered
POR
SubplateISO 4406 (1999); 18/16/13 (meet NAS 1638:7)+122 °FAuminumPilot Operated Pressure Reducing/Relieving207 bar-4 °FOilNitrile80 Gal/minHydraulic Valve Systems DivisionHydraulic Pressure5.3 kg100 to 3000Pressure Reducing in PAluminumNFPA D08; CETOP 8; NG25Nitrile